Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 10326 dokumen yang sesuai dengan query
cover
Pangaribuan, Adrianus
"A series of laboratory tests for electrical fires have been carried out by researchers, and some of the results have confirmed and been adopted as standard. However, the studies focus on electrical fires in PVC insulation material and the melting temperature and toxicity of PVC insulation. By focusing on heat conductors, the growth and spread of a fire can be eliminated by reducing the oxygen concentration, especially inside the compartment. Electrical fires are the most common cause of compartment and building fires both internationally and nationally, according to statistics (Liu & Benichou, 2008). Whatever the triggers are inside the electrical compartment on the connection, termination, or cable, this research looks into electrical fires caused by 1.0–1.5 mmsq electrical cables. Electrical fires in cables are normally started by increasing temperatures inside the cable conductor. By controlling and adjusting the oxygen concentration inside the electrical compartment under atmospheric concentration, one can hamper a fire’s start, trigger, propagation, and growth. This study investigates the effectiveness of oxygen concentration on preventing the growth of fires triggered by electrical cabling. A series of studies were created in laboratory scale in a horizontal compartment with oxygen levels of 19%, 17%, and 15%. This paper presents the results of this experiment by studying the effects of reducing oxygen concentration on the fire growth in cable network in a horizontal orientation. The results show that controlling the oxygen concentration at levels lower than atmospheric concentrations can effectively reduce the propensity for cable ignition and lower the fire propagation rate."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:2 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Muh. Syaiful Karim
"ABSTRAK
Kebakaran pada bangunan baik komersial maupun industri selama ini selalu mengkambing hitamkan listrik sebagai penyebab. Terlepas apakah benar kebakaran tersebut diakibatkan oleh listrik atau tidak namun hasil statistik baik international maupun nasional menyatakan bahwa kebakaran akibat listrik diatas 83 . Dari 83 kebakaran akibat listrik tersebut 90 dinyatakan bahwa kebakaran diakibatkan oleh hubungan pendek listrik electrical short circuit . Dari 90 kebakaran yang diakibatkan listrik 97 dimulai dari kabel ukuran kecil atau bisa dikatakan sebagai kabel yang digunakan sehari - hari dimana ukuran penampangnya antara 1 mm2 sampai dengan 2,5 mm2. Proses terjadinya kebakaran karena listrik dalam kondisi normal selalu dimulai dengan adanya perubahan atau kenaikan temperatur dalam inti kabel yang umumnya logam heat source dan adanya isolasi kabel pada kondisi tertentu berubah menjadi bahan bakar fuel dan oksigen yang tersedia. Pada kondisi normal komposisi oksigen di atmosfir sekitar 20,9 , nitrogen sekitar 78 dan sisanya diisi oleh komposisi gas lainnya sampai dengan 100 . Salah satu jalan untuk menghambat tumbuhnya api pada kabel listrik adalah dengan mengurangi konsentrasi oksigen sampai batas tertentu dimana pada konsentrasi ini api dapat dihambat bahkan dihindari pertumbuhannya, namun disisi lain penurunan konsentrasi oksigen ini harus masih dalam batas aman bagi manusia. Hasil penelitian ini dapat diaplikasikan pada panel listrik, ruang panel listrik, ruang kontrol, ruang IT dan ruang terbatas confined space dengan potensi penyalaan yang tinggi seperti adanya instalasi pengkabelan listrik. Untuk menguji pada konsentrasi berapa persen oksigen efektif dan bisa digunakan sebagai sarana pencegah kebakaran digunakan DSC Digital Scanning Calorimetre dan TGA Thermal Gravimetry Analysis . DSC akan menunjukkan berapa energi yang dibutuhkan untuk merusak isolasi dan mulai terdekomposisi, sedangkan TGA untuk melihat berapa banyak perubahan massa mass change yang terjadi.

ABSTRACT
Fire on buildings, both in commercial and industrial buildings always caused by electricity. Regardless whether the fire was caused by electrical system or not, but the results of both international and national statistics stated that the fire caused by electricity above 83 . From the 83 of the electrical fire caused, 90 stated that the fire caused by an electric fault. From the 90 of electrical fires, 97 trigerring and starting from small cables and wires or can be assumed the cable for daily common use with sizes among 1 mm2 to 2,5 mm2. The process of electrical fire on electrical cable on normal condition beginning from temperature changes or temperature increasing inside cable core that commonly made from metal heat source , their insulation becomes as fuel and existence of oxygen. In normal condition in atmospheric the composition of oxygen is 20,9 , nitrogen 78 and the rest was filled by another gas composition to 100 . One of the ways to inhibit the fire gowth on electrical cable is to reduce oxygen concentration to a certain where in this oxygen concentration fire growth can be avoid, however the decreasing of oxygen concentration should be safe for human life. This study can be applied on electrical distribution bard, electrical distribution room, control room, IT room and confined space with high potential igtion such as electrical cable installtion system. It as also possible to replacing exitiguishing system with characteristic could damage the environtment and electrical installation and its equipment protected. To investigate at what oxygen concentration is most effective used for fire prevention DSC Digital Scanning Calorimeter and TGA Thermal Calorimeter Gravimetry are use, DSC using to investigate energy needed to damage the cable insulation and begin to decomposition, while TGA to investigate how much are mass change during fire processing. "
2017
D2289
UI - Disertasi Membership  Universitas Indonesia Library
cover
Teguh Herbasuki
"Penyambungan kabel tanah 20 kV dengan menggunakan bahan isolasi Ethylene Propylene Rubber (EPR) sering menimbulkan permasalahan karena ada kemungkinan terjebaknya udara didalam rongga diantara lapisan isolasi, yang akan menyebabkan terjadinya medan listrik didalam rongga tersebut. Bila kekuatan medan listrik tersebut melebihi kekuatan tembus udara maka akan terjadi pelepasan muatan sebagian ( partial discharge ) pada isolasi dan lama-kelamaan isolasi mengalami kegagalan dalam fungsinya.
Pelepasan muatan sebagian akan menyebabkan terjadinya kuat medan listrik yang tidak homogen, dengan kekuatan medan listrik udara pada rongga akan lebih besar dari pada kekuatan tembus dalam isolasi. Pelepasan muatan sebagian ini bersifat mengikis dinding rongga, sehingga dinding rongga akan menjadi lebih besar, dengan demikian tingkat kekuatan isolasi akan semakin kecil dan akan memperpendek umur isolasi.
Dalam tesis ini dibahas masalah sejauh mana pengaruh rongga yang terjadi pada isolasi Ethylene Propylene Rubber ( EPR ) dalam sambungan kabel tanah 20 kV terhadap tegangan kritis yang dianggap sebagai penyebab awal terjadinya kegagalan isolasi akibat adanya pelepasan muatan sebagian internal ( internal partial discharge ).

A 20 kV Ethylene Propylene Rubber ( EPR ) insulation underground cable jointing often has air voids, causing electric fields in the voids. If the electrical field is bigger than the air breakdown gradient voltage a partial discharge appear in the insulation, in the long run a breakdown will happen and the insulation will not function.
The partial discharges will cause non homogenuous electric fields with the electric field in the void bigger than the breakdown gradient voltage of the insulation, eroding voids walls causing bigger voids dimensions, smaller insulation strength and shorter insulation ages.
In this thesis the influence of voids in Ethylene Propylene Rubber ( EPR ) insulation underground cable jointing on the critical voltage which is assumed to be the cause of insulation breakdown by internal partial discharge will be discussed.
"
Depok: Fakultas Teknik Universitas Indonesia, 2001
T2795
UI - Tesis Membership  Universitas Indonesia Library
cover
Eko Triswantoro
"Isolasi merupakan suatu hal yang sangat penting dan tidak dapat dipisahkan dengan peralatan tegangan tinggi. Transformator merupakan alat yang berperan besar dalam penyaluran tenaga listrik. Dalam hal ini minyak transformator berfungsi sebagai pemisah atau isolasi antara kumparan dengan peralatan yang berada di sekitarnya. Namun tingginya beban akan mengakibatkan pemanasan pada transformator yang dapat menyebabkan terdegradasinya minyak isolasi transformator dimana berakibat pada meningkatnya potensi terjadinya tegangan tembus.
Oleh sebab itu minyak isolasi memerlukan uji tegangan tembus yang bertujuan untuk mengetahui seberapa besar ia mampu menahan tegangan tinggi sampai mengalami kegagalan. Pengujian yang dilakukan adalah dengan membuat simulasi tegangan tembus menggunakan tiga jenis elektroda, elektroda runcing-runcing, kotak-kotak dan bola-bola serta menggunakan variasi temperatur dengan menggunakan minyak isolasi baru dan minyak isolasi lama. Selain itu pengujian tegangan tembus juga membuat variasi jarak antar elektroda dengan jarak 3 mm, 5 mm, dan 7 mm.
Setelah dilakukan pengujian diperoleh hasil bahwa dengan bertambahnya temperatur pada minyak isolasi maka tegangan tembus yang terjadi semakin menurun. Jenis elektroda runcing-runcing mempunyai tegangan tembus yang paling rendah, dan semakin jauh jarak antar elektroda maka tegangan tembus juga semakin besar. Minyak isolasi yang baru mempunyai tegangan tembus yang lebih besar dibanding dengan minyak isolasi lama.

Insulation is a very important and cannot be separated by high voltage equipment . The transformer is a tool that plays a major role in the distribution of electric power. In this case the function of transformer oil as a separator between the coil with the equipment located in the transformer. However, the high load on the transformer will result in heating which can lead to degradation of insulating oil which results in increased potential for breakdown voltage.
Therefore insulating oil require breakdown voltage test to find how much it is able to hold high voltages until fail. Testing is done by making simulated breakdown voltage using three types of electrodes , sharps, boxes and balls as well as the use of temperature variation using the new insulating oil and old insulation oil.
Besides testing the breakdown voltage also make variations of the distance between the electrodes with a distance of 3 mm , 5 mm , and 7 mm. After testing the results showed that with increasing temperature the insulating oil breakdown voltage occurs is decreased. Sharps type of electrode has the lowest breakdown voltage, and the greater the distance between the electrodes the breakdown voltage also increases. New insulating oil has a breakdown voltage greater compared with the old insulating oil."
Depok: Universitas Indonesia, 2014
S56108
UI - Skripsi Membership  Universitas Indonesia Library
cover
Farhan Aditya Wibowo
"Sistem HVAC pada office building berperan penting untuk menyediakan kenyamanan yang ideal bagi pengguna di dalamnya. Hal ini menyebabkan besarnya konsumsi energi di sektor perkantoran. Penelitian ini bertujuan untuk mengetahui efektifitas dan heat recovery dari penggunaan heat pipe heat exchanger dan return air. Volume return air yang digunakan dalam penelitian ini sebesar 30% dan HPHE yang digunakan berjumlah dua modul yang terdiri dari 3 baris heat pipe per modul. Pada inlet evaporator dialiri udara dengan variasi temperatur: 30, 35, 40, dan 45°C, serta dengan kecepatan 1,0; 1,5; dan 2,0 m/s. Beban pada ruangan bervariasi 200 dan 300W. Hasil dari percobaan ini mendapatkan nilai efektifitas HPHE terbesar pada percobaan temperature udara masuk 45oC; vin 1m/s; vout 2m/s; dan beban ruangan 200W yaitu sebesar 0,403 atau 40,3%. Heat recovery HPHE terbesar didapatkan pada percobaan temperature udara masuk 45oC; vin 2m/s; vout 2m/s; dan beban ruangan 200W yaitu sebesar 398,720W. Hasil dari penelitian menunjukkan bahwa penggunaan return air memengaruhi temperatur inlet evaporator.

HVAC systems in office buildings play an important role in providing ideal comfort for users in the building. This causes a large amount of energy consumption in the office sector. This study aims to determine the effectiveness and heat recovery from the use of heat pipe heat exchangers and return air. The return air volume used in this study was 30% and the HPHE used was two modules consisting of 3 lines of heat pipe per module. At the inlet of the evaporator, air flows with variations in temperature: 30, 35, 40, and 45°C, and with a speed of 1.0; 1.5; and 2.0 m/s. The load on the room varies between 200 and 300W. The results of this experiment get the greatest HPHE effectiveness value at the 45oC intake air temperature experiment; vin 1m/s; vout 2m/s; and 200W room load that is equal to 0.403 or 40.3%. The largest HPHE heat recovery was found in the 45oC intake air temperature experiment; vin 2m/s; vout 2m/s; and the room load is 200W, which is 398,720W. The results of the study indicate that the use of return water affects the inlet temperature of the evaporator."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Harahap, Ahmad Haikal
Depok: Universitas Indonesia, 1995
TA153
UI - Tugas Akhir  Universitas Indonesia Library
cover
Aprilia Erryani
"ABSTRAK
Liner adalah material elanstomer yang digunakan sebagai perekat dan insolator atau pelapis pelindung panas antara propelan dan tabung roket. Material liner yang cocok digunakan pada motor roket adalah komponen liner yang hampir sama dengan propelan agar propelan dapat merekat kuat pada liner. Komposisi liner yang digunakan pada penelitian ini adalah Hydroxyl-terminated polybutadiene (HTPB) sebagai resin polimer dan Toluene Diisosianat (TDI) sebagai curing agennya. Perbandingan komposisi HTPB dan TDI yang digunakan
adalah 12:1. Untuk meningkatkan sifat liner maka ditambahkan filler yang berperan penting sebagai material insulator. Pada penelitian ini filler yang digunakan adalah zirkonium Silikat (ZrSiO4). Telah dilakukan penelitian tentang pengaruh penambahan filler ZrSiO4 pada material liner roket propelan padat dengan komposisi filler 10% dan 5% berat variasi partikel 40, 100 dan 170 mesh.
Sifat liner yang diuji adalah sifat mekanik, termal, densitas dan viskositas. Hasil dari penelitian ini menunjukkan bahwa penambahan filler ZrSiO4 dapat meningkatkan sifat mekanik, termal, densitas dan viskositas liner. Berdasarkan syarat-syarat liner yang baik dapat disimpulkan bahwa komposisi liner yang tepat digunakan adalah 10% berat dengan ukuran partikel 100 mesh.

ABSTRACT
Liner is an elanstomer material used as adhesives and coatings insolator or heat shield between the propellant and rocket tubes. Liner material suitable for use in rocket motor liner component similar to the propellant for solid propellant can glue on liners. The composition of liner used in this study is hydroxy-terminated polybutadiene (HTPB) as the polymer resin and Toluene diisocyanate (TDI) as curing agent. Comparison of the composition of HTPB and TDI used was 12:1. To improve the properties of the liner then added filler material plays an important role as an insulator. In this study filler used is Zirconium Silicate (ZrSiO4). An investigation of the influence of filler addition ZrSiO4 on solid propellant rocket liner material with filler composition of 10% and 5% weight variation of the particle 40, 100 and 170 mesh. Liner properties tested were the mechanical properties, thermal, density and viscosity. The results of this study indicate that the addition of filler ZrSiO4 to improve the mechanical properties, thermal, density and viscosity liner. Under the terms of the well liner can be concluded that the exact composition of the liner used is 10% by weight with particle size of 100 mesh."
2011
T29772
UI - Tesis Open  Universitas Indonesia Library
cover
Philadelphia, PA: ASTM, 1985
620.112 23 COR
Buku Teks SO  Universitas Indonesia Library
cover
Putri Fadhillah Nugraha
"Pemanfaatan pipa kalor bersumbu sebagai penghantar kalor dua fase saat ini sudah tidak bisa diragukan lagi mengingat cukup banyaknya kelebihan yang dimilikinya. Sumbu kapiler berperan penting untuk meningkatkan kinerja pipa kalor. Sumbu tersebut dapat terbuat dari berbagai macam bahan, salah satunya adalah biomaterial dalam bentuk terumbu karang (corallia encrusting). Sebelum diaplikasikan, biasanya beberapa parameter sumbu kapiler harus diuji terlebih dahulu melalui serangkaian proses pengukuran konvensional untuk menentukan kinerja pipa kalor.
Tujuan dari penelitian ini adalah untuk menemukan metode baru pengukuran sumbu kapiler berdasarkan teknologi micro-CT scan dan pengolahan gambar digital (digital image processing), sehingga diharapkan metode tersebut dapat menghemat waktu dan tenaga.
Hasil penelitian menunjukkan bahwa sampel sumbu kapiler biomaterial memiliki nilai permeabilitas dan nilai porositas yang tidak jauh berbeda hasilnya antara pengukuran konvensional dan pengukuran dengan teknologi micro­-CT scan, yaitu hanya memiliki perbedaan pada range ±5%. Sementara itu untuk sampel pipa kalor, masing-masing bagian bawah, tengah, dan atas pipa kalor memiliki nilai porositas sebesar 20,98%, 25,73%, dan 24,18%, serta nilai permeabilitas sebesar 3,86 × 10-6 m2, 6,37 × 10-6 m2, dan 5,89 × 10-6 m2. Hasil tersebut menunjukkan korelasi yang sebanding antara nilai porositas dengan nilai permeabilitas suatu media berpori.

The use of heat pipe with wick as a two-phase heat transfer device nowadays is in great era since there are a lot of advantages it has. The wick itself has the important role for improving the heat pipe performance. It can be made from a variety of materials, such as biomaterial in the form of coral (corallia encrusting). Before being applied, the several parameters of heat pipe wick must be tested first through a series of conventional measurement methods to determine the heat pipe performance.
The purpose of this study is to find a new method for measuring capillary wick based on micro-CT scan technology and digital image processing, so that the method is expected to save time and effort.
The experiment results showed that the biomaterial capillary wick sample had permeability and porosity values that were not much different between the result of conventional measurement and the result of micro-CT scan measurement, which only differed in the range of ±5%. Meanwhile for heat pipe sample, each of bottom, middle, and top part of heat pipe had porosities of 20.98%, 25.73%, and 24.18%, as well as permeabilities of 3.86 × 10-6 m2, 6.37 × 10-6 m2, and 5.89 × 10-6 m2, respectively. These results showed the comparable correlation between porosity and permeability values of porous medium.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
T54080
UI - Tesis Membership  Universitas Indonesia Library
cover
Agus Sunjarianto P.
"ABSTRACT
Air conditioning system merupakan bagian sistem gedung yang memakai
Iistrik terbesar, mencapai 40% hingga 60% dari total konsumsi energi listrik untuk
gedung. Dengan keluarnya kebijakan pemerintah untuk mencabut subsidi atas biaya
penggunaan listrik secara berangsur-angsur hingga nol persen mengakibatkan
semakin meningkatnya biaya listrik. Dalam situasi persaingan yang menuntut
ditingkatkannya efisiensi di segala sektor, thermal storage merupakan salah ,satu
alternatif untuk menekan biaya pendinginan gedung.
Pada sistem pendinginan konvensional, semua peralatan AC dan pemipaan
dirancang untuk memenuhi beban puncak pendinginan. Sistem konvensional bekerja
pada beban puncak selama sistem bekerja. Beban puncak tersebut sesuai dengan
beban pendinginan maksimum pada rancangan untuk keamanan terpenuhinya beban
pendinginan yang sedang dibutuhkan. Konsep thermal storage yang dipakai pada
sistem pendinginan adalah sebagai salah satu alternatif dalam penggunaan peralatan
AC yang dirancang untuk memenuhi beban puncak, dengan memakai sistem yang
lebih kecil. Sistem ini akan beroperasi sepanjang hari menyimpan kelebihan
kapasitas pendinginan selama periode bukan beban puncak (off-peak periods) dan
menggunakan kapasitas pendinginan yang disimpan tersebut selama periode beban
puncak (on-peak periods).

"
1999
S36886
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>