Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8 dokumen yang sesuai dengan query
cover
Titi Panilia
"[ABSTRAK
Hidroksiapatit (HA) mempunyai peran penting dalam bidang medis karena komposisi kimia dan strukturnya yang mirip dengan tulang manusia. Material ini disintesis melalui metode hidrotermal dengan prekusor Ca(NO3)2, CaO dan NH3PO4. Variasi temperatur hidrotermal pada 150 ̊C dan 300 ̊C, temperatur sintering pada 900 ̊C selama 3 jam. Endapan yang diperoleh diuji dengan XRD dan SEM-EDX. Morfologi partikel hasil karakterisasi SEM berbentuk batangan memanjang dan melingkar teraglomerasi dan hasil uji EDX menunjukkan rasio Ca/P yang lebih besar dari 1.67. Uji XRD menunjukkan adanya fasa kalsium difosfat, fluorapatit dan apatit karbonat tipe- A di dalam endapan yang meningkatkan rasio Ca/P.
ABSTRACT
Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD.;Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD., Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD.]"
Universitas Indonesia, 2015
S62145
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yuli Dewi Pratiwi
"Tujuan penelitian ini adalah mengetahui visibilitas metode line profile sebagai metode kuantisasi citra digital dalam evaluasi diagnosis pemeriksaan abdomen pada pasien pediatrik. Kuantisasi citra dilakukan pada anatomi preperitoneal fat kanan-kiri 17 citra, lumen rongga usus besar 33 citra, dinding usus halus 33 citra, dan pelvis minor 22 citra . Sampel yang digunakan berupa citra pemeriksaan abdomen pasien pediatrik umur 0-1 tahun pada proyeksi AP Anterior-Posterior dengan diagnosis normal dan abnormal untuk masing-masing anatomi yang dievaluasi. Kuantisasi citra berupa kurva plot line profile didapatkan dengan menggunakan perangkat lunak ImageJ. Verifikasi metode line profile dilakukan dengan membandingkan grafik plot line profile dengan hasil diagnosis dokter pada masing-masing citra dan anatomi yang dievaluasi.
Hasil penelitian menunjukkan bahwa metode line profile dapat digunakan untuk evaluasi anatomi preperitoneal fat, lumen rongga usus besar, dan dinding usus halus dengan nilai kecocokan dengan diagnosis berturut-turut 70,59, 78,78 dan 100 . Penelitian lanjutan dengan modifikasi metode diperlukan untuk menganalisis probabilitas aplikasi metode line profile dalam evaluasi citra pemeriksaan abdomen.

The study was aimed to observe the feasibility of line profile method in digital image analyses for the evaluation of abdominal anatomy on pediatric patients. Image quantization and analyses were performed on the given anatomical interests of right left preperitoneal fat 17 images, colon lumen 33 images, small intestine wall 33 images, and pelvis minor 22 images . Samples used were abdominal AP antero posterior projections on pediatric patients ranging from 0 to 1 year old, each being interpreted as normal or abnormal by radiologists. Feasibility verification was performed by comparing line profile plot results obtained using ImageJ with radiologist interpretation on each images and anatomical interests.
Result shown that line profile method is applicable for preperitoneal fat, colon lumen and small intestine wall evaluation, being of 70.59, 78.78, and 100 match, respectively, to radiologists rsquo interpretations. Further study is essential to modify the method and allow subsequent studies on its potential clinical application.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
S66703
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sari Yuliani
"Penelitian ini bertujuan untuk mengevaluasi metode line profile sebagai cara kuantisasi dan analisa pemeriksaan sinus paranasal dalam citra computed radiography CR . Sampel berupa citra CR dari 45 pasien pediatrik dengan rentang usia 1-5 tahun, 5-10 tahun, dan 10-15 tahun dibagi berdasarkan anatomi yang dijadikan objek kuantisasi yaitu konka nasalis inferior, sinus maksilla, sinus frontal, sinus sphenoid, dan sinus ethmoid, dan dianalisa menggunakan metode line profile. Garis uji line profile dibuat dengan posisi dan ukuran tetap terhadap acuan berupa tulang bony landmark dengan menggunakan perangkat lunak ImageJ. Analisa dilakukan secara kualitatif; yakni membandingkan line profile pasien dengan hasil diagnosis radiolog, dan kuantitatif; yakni membandingkan line profile pasien didiagnosis abnormal dengan baseline dari line profile pasien didiagnosis normal. Hasil penelitian menunjukkan bahwa secara kualitatif metode ini menunjukkan efektivitas untuk anatomi objek konka nasalis inferior, sinus maksilla, dan sinus frontal dengan kecocokan antara kuantisasi dan hasil diagnosis radiolog sebesar 82, 81, dan 100 berturut-turut. Sedangkan secara kuantitatif metode ini efektif untuk objek sinus maksilla dan sinus frontal dengan tingkat kecocokan 89 pada sinus maksilla dan 50 pada sinus frontal.

This study was performed to quantize computed radiography images on paranasal sinuses examination of pediatric patients. Images of paranasal sinuses examination from 45 pediatric patients at the age ranges of 1 5 years, 5 10 years and 10 15 years were grouped by radiologists rsquo anatomical interests, namely inferior nasal concha, maxillary sinuses, frontal sinuses, sphenoidal sinuses and ethmoid sinuses. Test lines were positioned with respect to each image rsquo s bony landmarks, followed by quantization performed by generating a profile of pixel value along each test lines using ImageJ. The profiles were analyzed both qualitatively and quantitatively. Whereas qualitative analysis compared the line profile of patients diagnosed with and without abnormality by the radiologist, quantitative analysis compared the line profile of images with abnormality with a baseline generated from images without abnormality. Qualitative assessment shown that the method can be applied for anatomical interests of inferior nasal concha, maxillary sinuses, and frontal sinuses with an agreement to radiologist diagnosis of 82, 81 and 100, respectively. On the other hand, quantitative analysis demonstrated a feasibility of this method on anatomical interests of maxillary sinuses and frontal sinuses with 89 and 50 agreement to radiologist diagnosis for maxillary and frontal sinuses, respectively.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
S66704
UI - Skripsi Membership  Universitas Indonesia Library
cover
Saragih, Yuliasri
"Low dose computed tomography (LDCT) sangat baik digunakan dalam screening tetapi sangat sulit dalam mendeteksi adanya nodul. Penelitian ini dilakukan dengan cara membuat simulasi kgb di dalam paru (intrapulmonary lymph node) dan di daerah soft tissue. Simulasi kgb dimasukkan ke dalam gabus cork lalu disisipkan ke dalam 002LFC fantom CIRS toraks. Fantom tersebut dipindai dengan menggunakan 100 kV dan 120 kV pada 11, 25, 30, 50 mAs untuk LDCT dan 70, 80, 90, 100 mAs untuk SDCT. Hasilnya diperoleh bahwa terdapat perbedaan signifikan (p>0,05) antara nilai rata-rata SNR terhadap ukuran, bentuk dan komposisi IPLN pada low kV dan high kV. Jika dilihat secara visual, IPLN masih dapat dideteksi pada teknik LDCT dan SDCT untuk high kV maupun low kV sedangkan kgb pada soft tissue untuk LDCT khususnya pada 11 mAs dan 25 mAs untuk 100 kV dan 120 kV sangat sulit dideteksi dan SDCT pada 100 kV memiliki noise yang terlihat lebih besar dibandingkan pada 120 kV. Resolusi spasial citra dari MTF 10% yang terbaik didapatkan pada 120 kV, 30 mAs (LDCT). Kesimpulan dari penelitian ini adalah IPLN masih dapat dideteksi pada high kV, low kV untuk LDCT maupun SDCT sedangkan pada kgb yang berada di dalam soft tissue masih sulit untuk dideteksi pada low kV untuk LDCT.

Low Dose Computed Tomography (LDCT) is already well recognized for lung screening but it is still difficult to detect nodules. The lymph node simulations were put in the cork and paraffin then they both were inserted into the 002LFC CIRS thorax phantom. The phantom was scanned by using 100 kVp and 120 kVp at 11, 25, 30, 50 mAs for LDCT and 70, 80, 90, 100 mAs for SDCT. The results showed that there were significant (p>0,05)differences in average SNR values for varying sizes, shapes, and compositions of intrapulmonary lymph nodes (IPLNs). Visually, IPLNs could still be detected in LDCT and SDCT for high kVp and low kVp while lymph node in soft tissue for LDCT especially in 11 mAs and 25 mAs for 100 kVp and 120 kVp was very difficult to detect and the noise for 100 kVp SDCT technique was observed larger when compared to the 120 kVp SDCT. The best spatial resolution of images for 10% MTF is at 120 kVp, 30 mAs (LDCT). It can be concluded that IPLNs are still be able to detect at low and high kVp for LDCT and SDCT technique while lymph node in soft tissue is still difficult to detect at low kVp for LDCT."
2019
T54697
UI - Tesis Membership  Universitas Indonesia Library
cover
Galih Pangestu
"Teknik rekayasa jaringan digunakan untuk memperbaiki jaringan rusak dengan menggunakan pengganti biologis. Saat ini,para peneliti mengembangkan implan untuk rekayasa jaringan. Material berbasis polimer sebagai bahan implan banyak menarik perhatian karena biaya realtif murah, sumber berlimbah dan dapat diterima tubuh. Pendekatan material rekayasa jaringan tulang didasari dengan substansi dari material penyusun tulang. Pada penelitian ini digunakan hidroksiapatit yang berfungsi sebagai filler karena mampu memberikan kekerasan yang baik dan meningkatkan kemampuan adhesi (perekatan) sel. Silk Fibroin berfungsi sebagai matriks yang berfungsi untuk meningkatkan elastisitas dan sifat mekanik komposit. Hidroksiapatit berhasil ditumbuhkan pada silk fibroin dengan metode in-situ berbantukan iradiasi gelombang mikro (720 W; 15 menit). Larutan  SF yang telah diekstraksi dengan Adjisawa reagent dicampurkan dengan larutan kalsium fosfat yang telah dipreparasi menggunakan Ca(OH)2 dan (NH4)2HPO4 sebagai prekursor. Pengaruh rasio SF terhadap kekerasan komposit HA/SF diamati pada variasi rasio (v/v) yaitu HA90/SF10, HA80/SF20, dan HA70/SF30. Hasil XRD didapatkan bahwa ukuran kristal (L) dan indeks kristalinitas (CI) menurun seiring bertambahnya rasio SF pada komposit. Indeks kristalinitas terbesar terhitung pada sampel HA90/SF10 yaitu 32,6 dan 0.885. FTIR dipilih pada sampel HA70/SF30 didapatkan gugus fungsional utama yaitu pada bilangan gelombang 569, 608, 900, dan 1036, amida I pada bilangan gelombang 1636, amida II pada bilangan gelombang 1527 dan amida III pada bilangan gelombang 1264 yang menandakan bahwa HA dan SF saling mengikat menggambarkan bahwa kandungan SF mempengaruhi ukuran partikel, dimana semakin banyak kandungan SF maka semakin menurun ukuran partikel yang terbentuk. Hasil uji mekanik microvickers menunjukkan bahwa semakin banyak rasio SF dalam komposit HA/SF mengakibatkan semakin tinggi nilai kekerasan komposit ditandai dengan nilai kekerasan sampel HA70/SF30 yaitu 0,0335 GPa, sampel HA80/SF20 sebesar 0,0278 GPa dan sampel HA90/SF10 sebesar 0,0266.

Tissue engineering techniques are used to repair damaged tissue using biological substitutes. Currently, researchers are developing implants for tissue engineering. Polymer-based materials as implant materials have attracted a lot of attention because of their relatively low cost, wasteful sources and acceptable to the body. The bone tissue engineering material approach is based on the substance of the bone building material. In this study, hydroxyapatite was used as a filler because it was able to provide good hardness and increase cell adhesion. Silk Fibroin serves as a matrix that serves to increase the elasticity and mechanical properties of the composite. Hydroxyapatite was successfully grown on silk fibroin by in-situ method assisted by microwave irradiation (720 W; 15 minutes). The SF solution that had been extracted with Adjisawa reagent was mixed with a calcium phosphate solution that had been prepared using Ca(OH) 2 and (NH4)2HPO4 as a precursor. The effect of the SF ratio on the hardness of the HA/SF composite was observed in the variation of the ratio (v/v) namely HA90/SF10, HA80/SF20, and HA70/SF30. XRD results showed that the crystal size (L) and crystallinity index (CI) decreased with increasing SF ratio in the composite. The largest crystallinity index was calculated for the HA90/SF10 sample, namely 32.6 and 0.885. FTIR was chosen on the HA70/SF30 and the main functional groups were found at wave numbers 569, 608, 900, and 1036 ,amide I at wave number 1636 ,amide iI at wave number 1527 and amide III at wave number 1264 which indicates that HA and SF bind to each other. The SEM results show that SF content affects particle size, where the more SF content, the particle size was decrease. The results of the microvickers mechanical test showed that the higher the ratio of SF in the HA/SF composite, the higher the hardness value of the composite was indicated by the hardness value of the HA70/SF30 sample, which was 0.0335 GPa, the HA80/SF20 sample of 0.0278 GPa and the HA90/SF10 sample of 0.0278 GPa. 0.0266. "
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jasmine Amanda Purnamasari
"Bifasik kalsium fosfat (BCP) gabungan dari hidroksiapatit (HA) material bioaktif dengan ꞵ-Trikalsium Fosfat (ꞵ-TCP) material yang mudah diserap (resorbable). Karenanya, BCP mempunyai tingkat degradasi dan sifat osteokonduktif yang tinggi, sehingga berpotensi besar sebagai bahan pengganti tulang. Namun, BCP bersifat rapuh. Untuk memperbaiki sifat rapuh ini, BCP dikompositkan dengan kolagen karena kolagen mampu memperbaiki sifat BCP yang rapuh. Penelitian ini bertujuan untuk mensintesis komposit BCP/Kolagen dengan metode presipitasi basah secara ek-situ dengan rasio BCP/Kolagen: 90/10; 80/20 dan 70/30 (wt.%). BCP disintesis menggunakan iradiasi gelombang mikro 720 W selama 45 menit. BCP yang dihasilkan akan disintesis menjadi komposit BCP/Kolagen. Hasil XRD BCP murni menunjukkan adanya dua fasa yaitu HA (25%) dan β-TCP (75%). Kolagen berasal dari biowaste berupa GIL ayam. Hasil FTIR kolagen GIL memperlihatkan adanya gugus fungsional khas kolagen pada bilangan gelombang 3280 cm-1 (amida A), 2963 cm-1 (amida B), 1648 cm-1 (amida I), 1451 cm-1 (amida II), dan 1241 cm-1 (amida III). Sementara, hasil XRD komposit BCP/Kolagen menunjukkan terbentuknya fasa β-TCP, fasa HA, dan fasa impuritas oxyapatite dan phosphorous oxide pada semua variasi komposit BCP/Kolagen. Gugus fungsional khas (OH-), (PO43-) dan (N-H) hadir pada semua variasi terlihat pada hasil FTIR menandakan bahwa BCP dan kolagen telah berikatan. Hasil SEM memperlihatkan semakin banyak kandungan kolagen maka semakin kecil ukuran partikel yang terbentuk.

Biphasic calcium phosphate (BCP) is a combination of hydroxyapatite (HA) bioactive material with ꞵ-Tricalcium Phosphate (ꞵ-TCP) resorbable material. Therefore, BCP has a high level of degradation and osteoconductive properties, so it has great potential as a bone substitute. However, BCP is brittle. To improve this brittle nature, BCP combined with collagen because collagen can improve the brittle nature of BCP. This study aims to synthesize BCP/Collagen composites by wet precipitation ex-situ method with BCP/Collagen ratio: 90/10; 80/20 and 70/30 (wt.%). BCP was synthesized using microwave irradiation with 720 W power for 45 minutes and have two phases, namely HA (25%) and ꞵ-TCP (75%) from XRD results. The resulting BCP will be synthesized into BCP/Collagen composites. The collagen used was derived from biowaste of the inner layer of chicken gizzard (GIL). FTIR results of GIL collagen showed the presence of functional groups typical of collagen at wavenumbers 3280 cm-1 (amide A), 2963 cm-1 (amide B), 1648 cm-1 (amide I), 1451 cm-1 (amide II), dan 1241 cm-1 (amide III). Meanwhile, XRD results of BCP/Collagen composites showed the formation of ꞵ-TCP phase, HA phase, oxyapatite and phosphorous oxide impurities in all variations of BCP/Collagen composites. The characteristic functional groups (OH-), (PO43-) and (N-H) were present in all variations seen in the FTIR results indicating that BCP and collagen had bound. SEM results show that more collagen content the smaller the particle size formed, where the smallest particle size is owned by BCP/30 sample of 26.170 μm."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ulfah Fauziyah
"Hidroksiapatit (HA) merupakan biomaterial yang memiliki sifat bioaktif dan osteoinduktif. Akan tetapi HA juga memiliki sifat yang rapuh sehingga perlu dicampurkan dengan material polimer untuk meningkatkan sifat mekaniknya. Kolagen merupakan polimer alam yang dapat mendukung proses pertumbuhan sel tulang, dan memperbaiki karakteristik komposit serta dapat membentuk pori yang memungkinkan sel osteoblas untuk migrasi dan berpoliferasi seperti pada siklus darah. Gabungan kedua material ini dapat digunakan dalam proses regenerasi tulang. Dalam penelitian ini dilakukan sintesis HA dengan metode ek-situ berbantukan iradiasi gelombang mikro. Penelitian ini bertujuan untuk mempelajari pengaruh rasio kolagen terhadap nilai kekerasan komposit HA/Kolagen. Sintesis HA telah berhasil dilakukan menggunakan metode iradiasi gelombang mikro 720 W selama 15 menit. Kolagen yang digunakan merupakan kolagen hasil isolasi dari Chicken Gizzard inner lining (GIL) dengan metode perendaman basa NaOH 0.1 M. Kemudian HA dicampurkan dengan kolagen membentuk komposit HA/Kolagen dengan cara ek-situ menghasilkan material berpori dengan variasi rasio HA/Kolagen yaitu 90/10, 80/20, dan 70/30 (v/v). Hasil uji XRD komposit HA/Kolagen menunjukkan fasa HA terbentuk untuk semua variasi yang ditunjukkan pada sudut 2θ yaitu 26.03, 28.35, 33.05, 33.05 dan pada bidang miller (002), (210), (300), dan (310). Hasil perhitungan XRD didapatkan nilai indeks kristalinitas dan ukuran kristal paling rendah terdapat pada rasio HA/Kolagen 90/10 dengan nilai masing-masing 0.056 dan 29.247 nm. Hasil FTIR komposit HA/Kolagen menunjukkan keberadaan HA dengan gugus fungsi PO43- pada bilangan gelombang 565 cm-1, 604 cm-1, 1040 cm-1, dan O- pada bilangan gelombang 3565 cm-1. Sedangkan kolagen dengan gugus fungsi amida A (N-H stretching), amida B (C-H), amida I (C=O stretching), amida II (N-H bending), dan amida III (C-N stretching) pada bilangan gelombang masing-masing 3248 cm-1, 2922 cm-1, 1663 cm-1, 1404 cm-1, dan 1234 cm-1. Hasil SEM memperlihatkan bahwa ukuran partikel menurun ketika rasio kolagen meningkat. Hasil kekerasan vickers mencapai nilai maksimal pada sampel HA/Kolagen 90/10 dengan nilai 0.068 GPa dan menurun pada sampel HA/Kolagen 80/20 dan 70/30 yaitu 0.037 GPa.

Hydroxyapatite (HA) is a biomaterial that has bioactive and osteoinductive properties. However, HA has the brittle nature so it needs to be mixed with polymer materials to improve its mechanical properties. Collagen is a natural polymer that can support the growth process of bone cells, and improve the characteristics of composites and can form pores that allow osteoblast cells to migrate and proliferate as in the blood cycle. The combination of these two materials can be used in bone regeneration proccess. In this research, the synthesis of HA was carried out using the ex-situ method assisted by microwave irradiation. This research aims to study the effect of the collagen ratio to the hardness value of HA/Collagen composites. The synthesis of HA has been successfully carried out using the microwave irradiation method at a power of 720 Watt for 15 minutes. The collagen used is collagen isolated from Chicken Gizzard inner lining (GIL) with 0.1 M NaOH base immersion method. Then HA is mixed with collagen to form a HA/Collagen composite by ex-situ method to produce a porous material with a variation of the HA/Collagen ratio of 90/10, 80/20, and 70/30 (v/v). XRD test results of HA/Collagen composites showed that the HA phase was formed for all variations shown at 2θ angles, namely 26.03, 28.35, 33.05, 33.05 and in the Miller plane (002), (210), (300), and (310). The results of XRD calculation is the crystallinity index and the lowest crystal size were found at the ratio of HA/Collagen 90/10 with values of 0.056 and 29.247 nm. FTIR results for HA/Collagen composites showed the presence of HA with functional groups PO43- at wave number 565 cm-1, 604 cm-1, 1040 cm-1, and OH- in the wavenumber 3565 cm-1. Meanwhile, collagen with functional groups amide A (N-H stretching), amide B (C-H), amide I (C=O stretching), amide II (N-H bending), and amide III (C-N stretching) at wave numbers of 3248 cm-1, 2922 cm-1, 1663 cm-1, 1404 cm-1, and 1234 c-1. The results of the SEM test showed that the particles size is decrease while the collagen ratio is increase. Vickers hardness reached its maximum value in HA/Collagen 90/10 samples with a value of 0.068 GPa and decreased in HA/Collagen 80/20 and 70/30 samples 0.037 GPa."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Indah Lestariningsih
"Teknik akuisisi scan spiral memperkenalkan istilah Pitch. Pitch yang besar mempengaruhi proses rekonstruksi karena interpolasi data menjadi lebih lebar sehingga dapat menurunkan resolusi citra. Penelitian ini dilakukan dengan menggunakan fantom toraks in house yang dibuat dan didesain berdasarkan pengukuran data citra CT Toraks 100 pasien laki-laki. Parameter eksposi yang digunakan 130 kVp, rotasi tabung 0,6 detik, perubahan arus tabung 70 mAs dan 100 mAs serta variasi pitch mulai dari 0.5, 0.8, 1, 1.5, 1.8 dan 2. Fantom terbagi menjadi 4 bagian. Fantom bagian A untuk evaluasi akurasi posisi dan kualitas citra pada selang berisi media kontras, bagian B untuk evaluasi kualitas citra lubang udara hole , bagian C untuk evaluasi mikrokalsifikasi dengan variasi ukuran mesh pada serbuk tulang dan hidroxyapatite, dan bagian D untuk evaluasi MTF. Scanning fantom A untuk evaluasi akurasi posisi selang antara ukuran di fantom dengan monitor menunjukkan deviasi < 4 berjumlah 408 data 84 di sisi kanan dan 417 data 86 di sisi kiri dari total 486 data. Evalusi kualitas citra pada fantom A, terdapat perbedaan ?SNR pada tiap slice dengan hubungan yang linier terhadap perubahan pitch, semakin besar pitch yang digunakan ?SNR akan semakin lebar. ?SNR paling lebar terdapat pada slice ke-1 dan ke-2, selanjutnya pada slice ke-3 sampai ke-9 ?SNR stabil dan cenderung menurun. Evaluasi fantom B menunjukkan hole titik I dan J yang berdiameter 0.9 mm dan 0.625 mm tidak dapat tervisualisasi pada seluruh slice. SNR yang didapat paling tinggi pada hole tengah titik H dengan diameter 2 mm. Sensitivitas Pesawat CT dapat mendeteksi serbuk tulang ukuran mesh 10 dan 30 tetapi tidak dapat memperlihatkan serbuk tulang ukuran mesh 50 yang tersebar merata di permukaan fantom, ditunjukkan dengan nilai SNR tertinggi pada pitch 0.8 sebesar 2.659 SNR.

Acquisition technique in spiral scan introduce the term of Pitch. The big pitch could be influence for reconstruction process because interpolation will be wider, be affecting the spatial resolution. This study was performed by using in house thoracic phantom that made and designed based on image data measurement of CT Thorax of 100 men patient. Exposure Parameter which used was 130 kVp, tube rotation 0.6 second, tube current 70 mAs and 100 mAs, with pitch variation start from 0.5, 0.8, 1, 1.5, 1.8 and 2. Phantom was divided into 4 parts. Part A was used for evaluating the accuracy of position and image quality on a pipe that consist of contrast media, part B was used for evaluating image quality on hole, part C was used for evaluating micro calcification with various mesh size on bone material and hidroxyapatite, while part D was used for evaluating MTF. Phantom A scanning was performed for evaluating the accuracy of position between pipe in phantom and monitor showed deviation 4 with 408 number of data 84 on the right side and 417 data 86 on the left side from 486 all data. The result obtained for image evaluation, showed the different between delta SNR in every slice in phantom A with the pitch changing, used higher pitch becoming SNR wider. The widest SNR were occurred in the 1st and 2nd slice, furthermore in the 3rd until 9th slice SNR were stable and tend to decreased. Evaluation of phantom B showed that hole in point I and J which have diameter 0.9 mm and 0.625 mm could not visualized. The highest SNR was occurred in the middle hole point H with diameter 2 mm. The sensitivity of CT scanner is good enough to detect bone with the mesh size of 10 and 30 but not with the mesh size of 50 that spread in the phantom surface, this is shown with the highest SNR in the pitch 0.8 as 2.659 SNR."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T49787
UI - Tesis Membership  Universitas Indonesia Library