Nur Hidayah
"ABSTRAK
Telah dilakukan pengukuran percentage depth dose (PDD),berkas tissue phantom ratio ( ), profil dosis, faktor keluaran dan volume averaging pada radioterapi lapangan kecil menggunakan Film Gafchromic EBT3, ionisasi chamber CC01 dan CC13. Penelitian ini bertujuan untuk menentukan karakteristik keluaran berkas foton 6 MV lapangan kecil. Evaluasi pengukuran PDD dilakukan dengan menentukan nilai dan nilai . Profil dosis dianalisa berdasarkan nilai full width half maximum (FWHM) dan penumbra.
Hasil pengukuran menunjukkan bahwa nilai pengukuran dan dengan Film Gafchromic EBT3 memiliki perbedaan yang cukup signifikan pada Varian Clinac iX. Analisa pengukuran FWHM berkas profil, menunjukkan bahwa selisih nilai FWHM di setiap lapangan cenderung konstan yaitu ± 0.4 cm. Nilai deviasi terkecil dan terbesar faktor keluaran pada lapangan square terjadi ketika menggunakan ionisasi chamber CC13 yaitu 0.00% pada lapangan 1.6 × 1.6 cm² dan -23.05% pada lapangan 0.8 × 0.8 cm². Sementara pada lapangan circular, nilai deviasi terbesar terjadi ketika menggunakan ionisasi chamber CC13 yaitu 13.79% pada lapangan 0.8 × 0.8 cm². Nilai faktor koreksi volume averaging semakin meningkat seiring dengan semakin kecil ukuran luas lapangan. Hasil kalkulasi faktor koreksi volume averaging dapat memberikan kesimpulan bahwa Film Gafchromic EBT3 memiliki nilai faktor koreksi volume averaging yang lebih kecil dibandingkan dengan ionisasi chamber.

ABSTRACT
Percentage depth dose (PDD) measurements, tissue phantom ratio ( ), dose profile, output factor and volume averaging on small field radiotherapy using Gafchromic EBT3 Film, ionization chamber CC01 and CC13. The objective of this study was to determine the characteristic of 6 MV of depth and which were evaluated by PDD measurement. Dose profile was analyzed based on the value of full width half maximum (FWHM) and penumbra.
The measurement showed that the value of and which analyzed by Gafchromic EBT3 Film indicated significant value to Varian Clinac iX. FWHM measurement demonstrated of the beam profile showed that difference FWHM value in each field tends to be constan is ± 0.4 cm. The lowest and highest deviation of the output factor in the square field occured when used ionization chamber CC01 around of 1.14% in the field of 0.8 × 0.8 cm² and -23.05% in the field 0.8 × 0.8 cm². On the other had, the higher deviation at circular field occurs when using ionization chamber CC13 at about 13.79% in the field 0.8 × 0.8 cm². In addition, the correction factor of the volume averaging increased with inversely proportional to size of the field. The result of calculation of volume averagingcorrection factor can be concluded that Gafchromic EBT3 Film has a smaller volume averaging correction factor compared to ionization chamber.
"
2017
T49226
UI - Tesis Membership  Universitas Indonesia Library
cover
Asep Rachmat
"Detektor asap umumnya banyak digunakan pada bangunan tinggi. Akan tetapi, pada kenyataannya masih banyak pemanfaatan detektor asap yang kurang efektif sehingga kinerja dari detektor asap tidak optimal. Tujuan utama dari penelitian ini adalah untuk mempelajari karakteristik dari hasil pembakaran dua jenis bahan yang berbeda, yaitu jenis flaming (bensin) dan smouldering (foam) khususnya dari pergerakan asap yang dihasilkan serta pengaruhnya terhadap respon detektor asap. Dengan mengetahui karakteristik tersebut, diharapkan dapat dijadikan referensi untuk memilih detektor asap yang tepat.
Secara umum penelitian ini dilakukan dalam dua tahap, yaitu tahap simulasi dan tahap eksperimen. Simulasi dilakukan untuk mengetahui karakteristik dari hasil pembakaran. Kemudian eksperimen dilakukan untuk mengetahui pengaruh karakteristik tersebut terhadap tipe detektor asap yang digunakan.
Dari hasil simulasi didapatkan bahwa aliran asap pada pembakaran kedua jenis bahan bakar yang digunakan tergolong aliran laminar pada saat asap keluar dari sumbernya. Namun, kecepatan asap pada pembakaran bensin lebih tinggi dibandingkan dengan kecepatan asap pada pembakaran foam. Kemudian dari hasil eksperimen didapatkan bahwa detektor asap ionisasi lebih reaktif terhadap pembakaran jenis flaming, sedangkan detector asap fotoelektrik lebih reaktif terhadap pembakaran jenis smouldering.

Smoke detectors are widely used in buildings. However, the fact that smoke detector role and performance in a building are still not optimal and ineffective. The main objective of this research is to study the combustion characteristics of two different types of material, which is kind of flaming (petrol) and smouldering (foam), especially from the movement of smoke produced and the influence on smoke detector response. By knowing the characteristics, it is expected to be the reference for selecting the right smoke detector.
This study is generally done in two stages of simulation and experimental stage. The simulation is conducted to determine the characteristics of combustion products. Then experiments are conducted to determine the effect of these characteristics on the type of smoke detector used.
From the simulation results showed that the flow of smoke in the burning of both types of fuel used is laminar flow when smoke coming from the source. However, the speed of the smoke in the combustion of gasoline is higher than the velocity of smoke at the burning foam. Then, from the experimental results showed that ionization smoke detector is more reactive to flaming combustion type, while the photoelectric smoke detector is more reactive to smouldering combustion type.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50965
UI - Skripsi Open  Universitas Indonesia Library
cover
Oka Ananda Akbar
"ABSTRAK
TPS merupakan modalitas penting dalam perlakuan terapi karena salah satu fungsinya sebagai penyedia informasi dosis yang akan diterima target. Oleh karena itu jaminan kualitas TPS harus dilakukan untuk menjamin akurasi perhitungan dosis sehingga perlakuan terapi dapat bersifat optimal. Tujuan penelitian ini adalah melakukan verifikasi dosis kalkulasi TPS sebagai salah satu prosedur jaminan kualitas serta untuk mengetahui rentang deviasi jika terdapat perbedaan antara dosis kalkulasi dengan dosis pengukuran. Penelitian dilakukan menggunakan fantom CIRS 002LFC model toraks di dua center radioterapi dengan tahapan penelitian berdasarkan publikasi IAEA melalui TECDOC-1583. Pengukuran dosis titik menggunakan dosimeter bilik ionisasi 0.6 cm3, film gafchromic EBT3, dan TLD kemudian dosis pengukuran dibandingkan dengan dosis kalkulasi TPS. Hasil penelitian menunjukkan deviasi dosis pada seluruh kasus uji untuk kedua center radioterapi masih berada di dalam rentang tolerasi. Deviasi dosis di center radioterapi 1 bernilai 0.272.00% untuk bilik ionisasi 0.6 cm3, -0.081.79% untuk film gafchromic EBT3, dan -0.214.93% untuk TLD. Deviasi dosis di center radioterapi 2 bernilai -0.602.68% untuk bilik ionisasi 0.6 cm3, 0.151.75% untuk film EBT3, dan -3.906.30% untuk TLD. Nilai deviasi dosis yang tinggi umumnya diperoleh pada pengukuran dengan geometri kompleks seperti penggunaan blok, berkas tangensial, dan perputaran kolimator serta pengukuran pada material inhomogen (paru-paru dan tulang). Pengukuran di titik dengan perluasan penumbra (titik 10 kasus uji 6) gagal dilakukan menggunakan dosimeter bilik ionisasi namun menghasilkan deviasi yang rendah pada dua dosimeter lainnya. Kesimpulan dari penelitian in adalah semua unit TPS menunjukkan performa yang baik. Hasil pengukuran menunjukkan TLD merupakan dosimeter dengan akurasi dan presisi yang paling buruk. Tingkat akurasi keseluruhan dosimeter yang digunakan adalah film EBT3 dengan -0.05%, bilik ionisasi dengan -0.23%, dan TLD dengan -2.24%.

ABSTRAK
TPS is an important modality in therapy planning since it provides calculated dose information that will be received by target. Thus TPS quality assurance must be conducted to ensure the accuracy of dose calculation hence optimal therapy treatment could be achieved. The aim of this study is to verify TPS calculated dose as one of quality assurance procedures and also to know the deviation range if there are differences between calculated and measured dose. This study was performed using phantom CIRS thorax model 002LFC on 2 radiotherapy centers. The method of this study is based on IAEA TECDOC-1583. Point dose measurement was accomplished using 0.6 cm3 ionization chamber, gafchromic EBT3 film, and TLD then the measured dose was compared to calculated dose. The result of this study showed that the dose deviation of entire test cases on both radiotherapy centers are still below agreement criterion. Dose deviations on first radiotherapy center are 0.272.00% for 0.6 cm3 ionization chamber, -0.081.79% for gafchromic EBT3 film, and -0.214.93% for TLD. Meanwhile, dose deviations on second radiotherapy center are -0.602.68% for 0.6 cm3 ionization chamber, 0.151.75% for gafchromic EBT3 film, and -3.906.30% for TLD. Dose deviation out of agreement criterion generally discovered on measurement with complex geometry such as blocked field, tangential field, collimator rotation and measurement on inhomogen materials (lungs and bone equivalent) as well. Measurement on widening penumbra (point 10 test case 6) was failed to be conducted using ionization chamber yet yield dose deviation below agreement criterion with two others dosimeters. The conclusion of this study is all TPS units that were involved showed good performance of dose calculation. Measurement results also conclude that TLD is a dosimeter with the worst accuracy and precision. The accuracy order of dosimeters used in this study is gafchromic EBT3 film with -0.05%, ionization chamber with -0.23%, and TLD with -2.24%."
2016
S65043
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hentihu, Fatimah Kunti
"ABSTRAK
Tesis ini membahas mengenai faktor koreksi rekombinasi ion untuk bilik ionisasi pada berkas foton FFF Flattening-Filter-Free kemudian membandingkan hasilnya dengan berkas foton konvensional. Evaluasi faktor koreksi rekombinasi ion dilakukan untuk bilik ionisasi FC65-G, SNC600c dan CC13. Pengukuran menggunakan ketiga bilik ionisasi dilakukan di dalam fantom air dan menggunakan foton FFF dan foton konvensional 6 MV dari pesawat Varian Trilogy. Nilai faktor koreksi rekombinasi ion untuk ketiga bilik ionisasi kemudian diperoleh dari perhitungan dengan menggunakan metode dua tegangan sederhana dan fitting kurva Jaffe plot. Pengukuran juga dilakukan untuk beberapa variasi kedalaman dan variasi ukuran lapangan. Nilai faktor rekombinasi ion yang diperoleh secara keseluruhan dari ketiga bilik ionisasi menunjukkan bahwa nilai koreksi pada berkas foton FFF memilliki nilai yang lebih besar dibandingkan berkas foton konvemsional dengan perbedaan < 0,5 . Sementara dengan menggunakan beberapa variasi kedalaman dan ukuran, diketahui bahwa nilai koreksi rekombinasi ion berkurang dengan bertambahnya kedalaman variasi < 0,3 dan meningkat dengan bertambahnya ukuran lapangan variasi < 0,1 . Nilai koreksi rekombinasi ion yang diperoleh dari fitting kurva Jaffe plot linier memiliki perbedaan sebesar le; 7,649 bila dibandingkan dengan metode dua tegangan. Sementara perbedaan nilai koreksi rekombinasi ion yang diperoleh dari fitting kurva kuadratik dan fitting kurva kuadratik eksponensial terhadap metode dua tegangan adalah sebesar le; 0,5882 dan le; 1,798 . Selain koreksi rekombinasi ion, pada penelitian ini juga dilakukan evaluasi terhadap nilik faktor koreksi polaritas pada berkas foton FFF. Nilai koreksi polaritas berkas foton FFF dengan berkas foton konvensional memiliki perbedaan sebesar < 0,15 .. Nilai koreksi rekombinasi ion maupun koreksi polaritas untuk ketiga bilik ionisasi tidak memiliki perbedaan yang dignifikan bila dibandingan antara berkas foton konvensional dengan foton FFF.

ABSTRACT
This study focused on ion recombination factor for ionization chambers in FFF flattening filter free photon beams and then compared the result against conventional photon beams. The evaluation of ion recombination correction factor was performed using FC65 G, SNC600c, and CC13 ionization chambers. Measurements using the three ionization chambers were performed within the water fantom and using 6 MV FFF and conventional photon beams from the Varian Trilogy linac. The ion recombination correction factor value for the three ionization chambers were obtained from the calculation using the simple two voltage method and Jaffe plot curve fitting. Measurements were also performed for several depth and field size variations. The ion recombination factor value obtained from all three ionization chambers were higher for FFF photon beams than for the conventional photon beams with a difference of 0.5 . While using several variations of depth and size, the results showed that the ion recombination correction value decreased with increasing depth with variation 0.3 and increased with increasing field size with variation 0.1 . The ion recombination correction value obtained from the linear Jaffe plot curve fitting had a difference le 7.649 when compared to the two voltage method. While differences in ion recombination correction values obtained from quadratic curve fitting and exponential quadratic curve fitting to two voltage methods were le 0.5882 and le 1.798 . In addition to ion recombination correction, this study also evaluated the polarity correction factor in the FFF photon beams. The polarity correction value of FFF photon beam with conventional photon beam had a difference 0.15 . The value of ion recombination and polarity correction for the three ionization chambers in FFF photon beams has no significant difference compared to conventional photon beams.
"
2018
T51417
UI - Tesis Membership  Universitas Indonesia Library
cover
Lidwina Deviani Likasa
"Bawang putih dianggap sebagai salah satu tumbuhan terpenting, dilihat dari berbagai macam kegunaannya, baik sebagai bahan mentah untuk tujuan kuliner atau sebagai ramuan obat. Diallil disulfida (DADS) dan diallil trisulfida (DATS) merupakan senyawa organosulfur yang terdapat dalam bawang putih, yang sangat berkontribusi atas sifat bioaktif dan aroma khas pada bawang putih. DADS dan DATS juga terkenal dengan sifat antioksidannya. Penelitian ini bertujuan untuk memperoleh kondisi analisis optimum campuran DADS dan DATS agar diperoleh metode yang valid untuk digunakan pada penetapan kadar DADS dan DATS pada bawang putih tunggal dan bawang putih siung. Analisis dilakukan menggunakan kromatografi gas dengan detektor ionisasi nyala, kolom HP-1. Suhu awal kolom 140℃ dengan kenaikkan 1℃/menit hingga 180℃. Suhu injektor dan detektor diatur 200℃, laju alir gas pembawa 0,80 mL/menit, volume penyuntikkan 1,0 μL. Kondisi analisis yang telah dioptimasi kemudian divalidasi mencakup selektivitas, linearitas, akurasi, presisi, batas deteksi, batas kuantitasi. Hasil validasi didapatkan nilai koefisien korelasi (r) untuk DADS sebesar 0,9999 pada konsentrasi 0,5-20 μg/mL dengan persamaan garis y = 13068,97x - 3373,62. Pada DATS didapatkan nilai koefisien korelasi (r) sebesar 0,9999 pada rentang konsentrasi yang sama, dengan persamaan garis y = 3194,39x - 307,22. Nilai LOD dan LOQ untuk DADS sebesar 0,3063 μg/mL dan 1,0210 μg/mL, sedangkan untuk DATS sebesar 0,1986 μg/mL dan 0,6621 μg/mL. Didapatkan nilai akurasi dengan rentang %UPK antara 98,05-101,76% dan presisi dengan %KV≤2%. Dari hasil penelitian menunjukkan bahwa metode analisis yang digunakan dinyatakan valid karena memenuhi seluruh kriteria. Hasil menunjukkan pada sampel bawang putih tunggal diperoleh kadar rata-rata DADS sebesar 0,0296% dan DATS sebesar 0,0093%. Sedangkan, pada sampel bawang putih siung diperoleh kadar rata-rata DADS sebesar 0,0248% dan DATS sebesar 0,0087%.

Garlic is treated as one of the most important plants that can be seen from its various uses, whether as food ingredients or as a part of medicational purposes. Diallyl disulfide (DADS) and diallil trisulfide (DATS) are organosulfur compound that can be found in the garlic, which highly affect the characteristic of the aroma of the garlic itself and the bioactive properties. DADS and DATS are also well known for its antioxidants properties. The purpose of this research is to observe the optimum analysis condition of DADS and DATS in order to obtain a valid method to be used in determining DADS and DATS levels in garlic and single clove garlic. The analysis was performed using gas chromatography with flame ionization detector, column HP-1. Initial temperature of column was set from 140℃ with an increase of 1℃/min to 180℃. The injector and detector temperature was set to 200℃, carrier gas flow rate was 0,80 mL/min, and the injection volume was 1.0 μL. The optimized conditions of analysis are then validated which include selectivity, linearity, accuracy, precision, limit of detection, and limit of quantification. Validation shows that the coefficient of correlation (r) for DADS is 0,9999 in the range of concentration 0,5-20 μg/mL with linear regression y = 13068,97x -3373,62. Moreover, the coefficient of correlation for DATS is 0,9999 in the range of the same concentration, with linear regression y = 3194,39x - 307,22. The values of LOD and LOQ for DADS are 0,3063 μg/mL and 1,0210 μg/mL, respectively. Meanwhile, the LOD and LOQ for DATS are 0,1986 μg/mL and 0,6621 μg/mL, respectively. The percentage of recovery is in the range of 98,05-101,76% and CV≤2%. This research indicates the use of analytical method is valid because it meets the criteria. Last but not least, the results shows on single clove garlic sample, the average level of DADS and DATS are 0,0296% and 0,0093%, respectively. Meanwhile, on garlic sample, the average level of DADS and DATS are 0,0248% and 0,0087%, respectively.
"
Depok: Fakultas Farmasi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library