Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 116 dokumen yang sesuai dengan query
cover
Hendya Perbangkara
"ABSTRAK
Perkembangan CT scan generasi multislice yang begitu pesat membuat pemeriksaan CT angiografi coroner sering dilaksanakan, akan tetapi pemberian informasi tentang dosis yang di terima pasien masih jarang dilakukan. Sehingga perlu dilakukan estimasi dosis pasien pada pemeriksaan CT angiografi coroner untuk mengetahui nilai dosis yang diterima oleh organ-organ yang sensitive terhadap radiasi seperti esophagus, paru-paru, payudara (pada wanita) dan jantung. Estimasi dosis dilakukan menggunakan program imPACT® dengan nilai nCTDIw didapat dari hasil pengukuran mengunakan detector pencil ion chamber menggunakan phantom acrilic 32 cm. Dari hasil estimasi di dapat dosis ekivalen yang diterima jantung 110 mSv ? 140 mSv, dosis efektif esophagus (thymus) 2,9 mSv ? 5.7 mSv, dosis efektif paru-paru 10 mSv -14 mSv, dosis efektif payudara 10 mSv ? 13 mSv dan total dosis efektif berkisar antara 31 mSv ? 42 mSv. Mengingat nilai total dosis efektif yang diterima pasien cukup tinggi, maka pasien CT angiografi coroner harus mendapatkan justifikasi yang kuat.

ABSTRACT
The Fast development of CT generation makes CT angiography coroner examination more frequence to be done, but the dose information of patient is rarely to be done. So it require to make patient dose estimation on CT angiography coroner examination. In order to know the dose receive by sensitive organ set of oesophagus, lung, brest and heart. Dose estimation is done using imPACT® program, using CTDI value obtain measurement using acrylic phantom with 32 cm diameter. From dose calculation the dose equivalent by heart is between 110 mSv - 140 mSv, and effective dose for oesophagus 2.9 mSv ? 5.7 mSv, lung 10 mSv ? 14 mSv and total effective dose between 31 mSv ? 42 mSv. Because effective dose receive by patient is very high, the CT angiography coroner patient must have a very strong justification. "
Universitas Indonesia, 2011
S651
UI - Skripsi Open  Universitas Indonesia Library
cover
Burke, Michael P.
Boca Raton: CRC Press, Taylor & Francis Group, 2012
614.1 BUR f
Buku Teks SO  Universitas Indonesia Library
cover
Firman Sadikin
"Proteksi adalah pengaman pada sistem tenaga listrik yang terpasang pada sistem distribusi tenaga listrik, trafo tenaga, transmisi tenaga listrik dan generator listrik dipergunakan untuk mengamankan sistem tenaga listrik dari gangguan listrik atau beban lebih dengan cara memisahkan bagian sistem tenaga listrik yang terganggu dengan sistem tenaga listrik yang tidak terganggu sehingga sistem kelistrikan yang tidak terganggu dapat terus bekerja. Kegagalan sistem proteksi pada gardu KG02 dan KG180 di PT PLN (Persero) UP3 Tanjung Priok saat terjadi arus gangguan hubung singkat phasa-phasa disisi konsumen mengakibatkan PMT (Pemutus Tenaga) Penyulang trip. Hal ini mengakibatkan pemadaman meluas yang berdampak buruknya citra PT PLN (Persero) UP3 Tanjung Priok terhadap kehandalan jaringan. Untuk mengetahui penyebab kegagalan sistem proteksi dilakukan pengecekan CT (Current Transformer) terhadap kedua gardu. Pada gardu KG02 kontrak daya 345 kVA, CT yang terpasang dengan ratio 10/5 dan class 5P10 dengan arus gangguan 2861 A. Pada gardu KG180, CT yang terpasang dengan ratio 100/5 dangan class 5P10 dengan arus gangguan 6547 A. Dari hasil data kedua gardu diatas, kegagalan sistem proteksi terjadi pada Transformator Arus yang jenuh saat dialiri arus gangguan melebihi 2861 A dan 6547 A. Untuk mengatasi kegagalan proteksi pada kedua gardu diatas dibutuhkan penambahan CT Ring 800/5 dengan class 5P20 dengan hasil pengujian tersebut dapat menjadi acuan untuk perbaikan sistem proteksi sehingga kegagalan serupa tidak terulang kembali.

Protection is a safeguard in the electric power system installed in the electric power distribution system, power transformers, electric power transmission, and electric generators used to protect the electric power system from electrical disturbances or overloads by separating the disturbed part of the electric power system from the existing electric power system. Not disturbed so that the uninterruptedelectrical system can continue to work. Failure of the protection system at the KG02 and KG180 substations at PT PLN (Persero) UP3 Tanjung Priok when short circuit currents occurred on the phases on the consumer side resulted in the PMT (Power Breaker) of the feeder tripping. This resulted in widespread outages which had a negative impact on the image of PT PLN (Persero) UP3 Tanjung Priok regarding network reliability. To find out the cause of the protection system failure, CT (Current Transformer) checks were carried out on the two substations. At the KG02 substation, the 345 kVA, CT power contract is installed with a ratio of 10/5 and class 5P10 with a fault current of 2861 A. At the KG180 substation, the CT is installed with a ratio of 100/5 with class 5P10 with a fault current of 6547 A. From the results of the data from the two substations above, the protection system failure occurred in the current transformer which was saturated when a fault current exceeded 2861 A and 6547 A. To overcome protection failures at the two substations above, it is necessary to add a CT Ring 800/5 with class 5P20, with the test results being a reference for improving the protection system so that similar failures do not happen again."
Jakarta: Fakultas Teknik Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Khairul Mar`ie
"Computed Tomography (CT) Scanner merupakan modalitas pencitraan tubuh tiga dimensi. Untuk observasi organ tubuh yang bergerak, selain menggunakan Singlesource CT (SSCT) telah dikembangkan pula Dual-source CT (DSCT) yang dilengkapi dengan sumber sinar-X primer dan sekunder. Posisi kedua sumber DSCT membentuk sudut 90°, dan pada saat akuisisi citra keduanya berputar 90°. Dengan demikian proses akuisisi citra organ tubuh yang bergerak dapat dilaksanakan dalam waktu yang relative singkat. Berbagai pengujian untuk menganalisis kualitas citra biasanya dilakukan menggunakan fantom. Berbagai macam jenis fantom yang telah dibuat dengan menggunakan material ekuivalen jaringan telah banyak dikembangkan. Dalam meningkatkan studi fantom untuk menganalisa kualitas citra CT scan yang meliputi pengukuran detectability, noise, dan resolusi spasial pada penelitian ini dilakukan suatu konstruksi dan pengembangan fantom desain khusus (in-house) yang terdiri dari beberapa material ekuivalen jaringan. Fantom terdiri dari 3 bagian. Fantom in-house yang dibuat digunakan untuk analisis kualitas citra dan dikhususkan untuk QC pada DSCT dan SSCT. Fantom in-house yang di buat telah dilakukan uji coba dan dapat digunakan untuk evaluasi kualitas citra dari DSCT dan SSCT. Hasil pengukuran detektabilitas, menunjukkan DSCT mampu mendeteksi objek dengan kontras rendah pada objek pipa silinder berukuran 2 mm. Pengukuran SNR pada citra SSCT didapatkan terjadinya peningkatan nilai SNR seiring dengan pertambahan mAs, dan nilai SNR objek pada bagian perifer tidak selalu sama daripada center dikarenakan proses scanning helical. Pengukuran resolusi spasial menunjukkan nilai MTF 10% dari DSCT lebih rendah di bandingkan dengan dengan SSCT. Perbedaan mAs yang digunakan tidak berpengaruh terhadap MTF 10% yang dihasilkan.

Computed Tomography (CT) Scanner is a three-dimensional body imaging modality. Instead of using Single-Source CT (SSCT), the observation of moving organs could be performed also by Dual-Source CT (DSCT) that has been developed recently. DSCT is equipped with primary and secondary x-ray sources. The position of the two sources DSCT forms an angle of 90°, and at the time of image acquisition, both rotate 90°. This new technology of CT could reduce the scan time so that the process of image acquisition of a moving body can be carried out in a relatively short time. A special phantom would be needed to perform several testing procedures for analyzing the image quality. Many phantom modules were designed with tissue-equivalent materials. The proposed in-house phantom was aimed to enhance the phantom study in order to analyze the CT scan image quality: detectability, noise and spatial resolution. The phantom was special designed and constructed with several tissue-equivalent materials. The phantom was consist of three part modules. This in-house phantom can be used for image quality analyzis for both quality control (QC) of DSCT and SSCT. The in-house phantom was tested and image quality evaluation of DSCT and SSCT can be succesfully performed with the phantom. The detectability measurement shows that DSCT was able to detect the object with low contrast in cylidrical pipe object with 2 mm diameter. The SNR measurement for noise test in SSCT image shows that the SNR tends to rise proportional to the mAs increment. The SNR value of the object in periferal region seems to be higher compared to the SNR value from the central region, due to the helical scanning process. The highest SNR value shows the lowest noise. The spatial resolution shows that 10% MTF value from DSCT is lower than SSCT. It means that SSCT represents the better spatial resolution compared to DSCT. The mAs difference during this work was not affect the 10% MTF value produced.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T55298
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Agil Nur Hidayat
"Coronavirus Disease-2019 atau COVID-19 merupakan penyakit yang disebabkan oleh Virus SARS-CoV-2. Program vaksinasi dan pengecekan dengan alat RT-PCR terus dijalankan demi mengetahui dan mencegah penyebaran penyakit. Dalam hal ini cycle threshold (Ct) value digunakan untuk mendiagnosa atau memprediksi infeksi COVID-19. Penelitian dilakukan dengan desain cross sectional menggunakan data retrospektif yang diperoleh dari sumber data sekunder. Data diperoleh dari Laboratorium Helix Depok dan Dinas Kesehatan Kota Depok periode Januari hingga Desember 2021. Dari 1060 data sampel Ct value serta faktor-faktor yang mungkin memengaruhinya, dilihat hubungannya dengan variabel usia, jenis kelamin, serta riwayat vaksinasi (jenis vaksin dan waktu pemberian vaksin). Hasil yang didapatkan dari profil Ct value Januari hingga Desember 2021 menunjukkan adanya penurunan Ct value di bulan Juni – Juli 2021. Jenis kelamin (Gen N, p=0,509; ORF1AB, p=0,447) dan usia (Gen N, p=0,482; ORF1AB p=0,764) tidak signifikan memengaruhi nilai Ct value. Sedangkan jenis vaksin non-Coronavac (Gen N, p=0,001; ORF1AB, p=0,001) dan waktu vaksinasi kurang dari 30 hari sebelum terjadinya infeksi (Gen N, p=0,002; ORF1AB, p< 0,001) secara signifikan berhubungan dengan nilai Ct value yang lebih tinggi (di atas median). Berdasarkan hasil penelitian ini, diketahui bahwa terjadi peningkatan jumlah kasus sejalan dengan penurunan rerata Ct value pada bulan Juni dan Juli 2021. Nilai Ct value tidak dipengaruhi usia dan jenis kelamin, namun jenis vaksin non-Coronavac serta waktu pemberian vaksin kurang dari 30 hari sebelum terjadinya infeksi berhubungan dengan nilai Ct value yang lebih tinggi, menunjukkan efektivitasnya dalam menurunkan keparahan penyakit.

Coronavirus Disease-2019 or COVID-19 is a disease caused by the SARS-CoV-2 Virus. Vaccination programs and checking with RT-PCR tools continue to be carried out in order to find out and prevent the spread of the disease. In this case, the cycle threshold (Ct) value is used to diagnose or predict COVID-19 infection. The study was conducted with a cross sectional design using retrospective data obtained from secondary data sources. Data were obtained from Helix Depok Laboratory and Depok City Health Office from January to December 2021. From 1060 sample data, the Ct value and factors that might affect it were examined in relation to the variables of age, gender, and vaccination history (type of vaccine and time of vaccine administration). The results obtained from the Ct value profile from January to December 2021 showed a decrease in Ct value in June - July 2021. Gender (Gene N, p=0.509; ORF1AB, p=0.447) and age (Gene N, p=0.482; ORF1AB p=0.764) did not significantly affect the Ct value. Non-Coronavac vaccine type (Gen N, p=0.001; ORF1AB, p=0.001) and vaccination time less than 30 days before infection (Gen N, p=0.002; ORF1AB, p<0.001) were significantly associated with higher Ct values (above median). Based on the results of this study, it is known that there was an increase in the number of cases in line with the decrease in the average Ct value in June and July 2021. Ct value was not influenced by age and gender, but non-Coronavac vaccine type and vaccine administration time less than 30 days prior to infection were associated with higher Ct value, indicating its effectiveness in reducing disease severity."
Depok: Fakultas Farmasi Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Siregar, M. Arifin
"ABSTRAK
Sistem pelayanan CT Scan yang diselenggarakan UPF Radiodiagnostik RS. Dr. Cipto Mangunkusumo setiap tahun cenderung mengalami antrian pasien yang panjang. Berdasarkan wawancara dan pengamatan lokasi penelitian, ternyata antrian pasien yang membutuhkan pelayanan CT Scan mencapai dua minggu lamanya. Dengan mengacu pada REPELITA ke V RSCM Tahun 1989, bahwa salah satu upaya yang akan dilakukan adalah peninngatan mutu pelayanan medis agar dapat memberikan pelayanan yang cepat, tepat, aman dan efisien, maka antrian yang terjadi pada sistem pelayanan CT Scan merupakan salah satu masalah yang harus di atasi.
Penelitian ini bertujuan untuk mengetahui karakteristik antrian pada sistem pelayanan CT Scan dengan menggunakan model M/M/1 dari queueing (waiting line) theory dan untuk mendapatkan faktor-faktor yang dapat meningkatkan pelayanan CT Scan menjadi lebih optimal.
Dari hasil penelitian ini dapat disimpulkan bahwa tingkat kegunaan fasilitas pelayanan CT Scan belum optimal. Pasien tidak ada yang dilayani tepat jam 08:00 WIB dan umumnya pelayanan telah selesai sebelum jam 14:00 WIB.
Akhirnya dua saran yang dikemukakan untuk mengatasi masalah antrian ini, yaitu penambahan peralatan CT Scan dan penyempurnaan metode kerja yang sesuai bagi sistem pelayanan CT Scan di UPF Radiodiagnostik RS.Dr. Cipto Mangunkusomo"
1990
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Nugroho Iman Wibisono
"Pemanfaatan sinar x sebagai pemindai organ guna menegakan diagnostik masih menjadi pilihan popular dalam dunia kesehatan. Di dalam dunia medis CT Scan cukup memberikan nilai kontribusi dosis yang tinggi. Sehingga perhitungan terhadap dosis yang diterima tubuh dalam pemeriksaan CT Scan penting untuk dipantau. Hingga saat ini yang menjadi referensi dosis, yang diterima pada pemeriksaan CT Scan umumnya menggunakan metode perhitungan CTDI, menggunakan Panthom PMMA yang berbentuk bulat atau silinder. Dan realitasnya postur tubuh manusia tidak bulat sempurna, sehingga penulis merasa perlu diadakan koreksi geometri terhadap phantom PMMA yang digunakan dengan postur tubuh manusia. Untuk itu penulis melakukan survey tebal tubuh manusia sebagai nilai koreksi geometri tersebut, dengan ukuran dewasa dengan rentang usia diatas 15 tahun,adalah 23 cm (kepala),31 cm (rongga thorax), 29,6 cm (abdominal) dan ukuran anak - anak, rentang usia 1-15 tahun, adalah 17 cm (kepala), 21 cm (rongga thorax), 21 cm (abdominal) kemudian merealisaikannya dalam variasi ukuran phantom, sehingga didapat nilai normalisasi CTDI dalam berbagai ukuran. Penggunaan tebal irisan atau bukaan kolimasi yang lebih kecil akan memberikan nilai CTDIw yang lebih tinggi bila dibandingkan dengan penggunaan tebal irisan atau bukaan kolimasi yang lebih besar, yang dapat dilihat pada pesawat single slice antara tebal slice 3 mm dengan 1 mm memiliki prosentase rasio nilai CTDIw 3 mm terhadap 1 mm sebesar 50,3%? 51,6%. Sedangkan pada pesawat multi slice rasio prosentase tersebut adalah 105,1%-108,2% pada bukaan kolimator 5 mm dengan 1,2 5mm, begitu pula dalam penggunaan variasi ukuran phantom rasio prosentase nilai CTDIw pada pesawat single slice antara phantom 16 cm dengan 10 cm sebesar 75,3% - 77%, sedangkan pada pesawat multi slice prosentase rasio tersebut adalah 76,9 % ? 82,4 % antara phantom diameter 16 cm dan 10 cm, maka didapat nilai CTDIw Phantom 10 > nilai CTDIw Phantom 16 > nilai CTDIw Phantom 32. Sehingga perlu diperhatikan nilai dosis pada organ dengan diameter yang lebih kecil (pada anak-anak), dikarenakan nilai dosis yang diterima organ dengan diameter lebih kecil akan berbeda dengan organ yang diameter besar, walau menggunakan kondisi atau parameter pesawat yang sama.

Utilization of x-rays as an organ in order to establish diagnostic scanner is still a popular choice in the health world. In the world of medical CT scans give a fairly high dose contribution. So that the calculation of the dose received in the body CT scan is important to monitor. Until now the reference dose, which received CT scans generally use CTDI calculation method, using PMMA Panthom round or cylinder shaped. And the reality is the human's body is not perfectly round, so I felt needed to be corrected geometry of PMMA phantom used with the human's body. To the authors conducted a survey of the human body thick as the geometry correction value, with an adult size by age range above 15 years old, is 23 cm (head), 31cm (thoracic cavity), 29.6 cm (abdominal) and the size of the children, the range 1-15 years old, is 17 cm (head), 21 cm (thoracic cavity), 21 cm (abdominal) then aplicated in phantom size variation, so the normalized CTDI values obtained in various sizes. The use of thick slices or smaller openings colimation will provide CTDIw a higher value when compared with the use of thick slices or colimator larger openings, which can be viewed on a single slice plane between 3 mm with 1 mm thick slice has the percentage ratio of the value CTDIw 3 mm to 1 mm amount to 50.3% - 51.6%. While on the plane multi-slice percentage ratio was 105.1% -108.2% at 5 mm aperture collimator with 1.25 mm, as well as variations in the use of phantom size ratio of the percentage of the value CTDIw on a single plane between the phantom of 16 cm by 10 cm by 75 , 3% - 77%, while on the plane multi-slice percentage ratio was 76.9% - 82.4% between the phantom size of 16 cm and 10 cm, so that the obtained values CTDIw Phantom 10 > value CTDIw Phantom 16 > value CTDIw Phantom 32 Thus, to consider the dose to the organ with a smaller diameter (in children), because the value of the dose received organs with a smaller diameter will vary with the diameter of the organ, although the conditions or parameters using the same plane"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
S42344
UI - Skripsi Open  Universitas Indonesia Library
cover
Anak Agung Bagus Ngurah Nuartha
Jakarta: Fakultas Kedokteran Universitas Indonesia, 1986
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Yolandita Ayu Lestari
"Radioterapi adalah suatu modalitas penanganan kanker dengan memanfaatkan radiasi pengion. Teknik radiasi yang saat ini menjadi perhatian adalah radiasi partikel, salah satunya adalah proton. Proton memiliki karakteristik puncak bragg (Bragg peak) yang mendepositkan energinya pada jangkauan kedalaman tertentu. Salah satu teknik penyinaran radioterapi adalah Intensity Modulated Proton Therapy (IMPT). IMPT memiliki beam spot yang berukuran sangat kecil, sehingga memungkinkan distribusi dosis lebih konformal terhadap target. Organ paru-paru memiliki pergerakan yang membuat tantangan dalam pengerjaanya. Untuk mengurangi pengaruh pergerakan digunakan teknik 4D Computed Tomography (4DCT). Penelitian ini bertujuan untuk mengetahui tingkat efektivitas pengobatan kanker di paru-paru pada teknik radioterapi proton yang dibandingkan dengan radiasi foton sebagai acuan dasarnya. Selain itu, studi ini juga bertujuan untuk mengetahui besar perbedaan tingkat efektivitas perencanaan antara 3D CT dan 4D CT. Tingkat efektivitas perencanaan berdasarkan tiga parameter. Parameter tersebut yaitu Conformity Index (CI), Homogeneity Index (HI), dan Gradient Index (GI). Terdapat perbedaan yang cukup signifikan dari hasil perencanaan di kedua fantom tersebut. Untuk nilai CI dan HI nilai terbaik dapat dicapai pada fase ekspirasi. Namun untuk GI nilai terbaik dapat dicapai pada fase 0%. Dosis pada spinal cord setiap perencanaan, tidak memiliki perbedaan yang cukup signifikan. Kami menemukan pada paru-paru dengan teknik IMRT di fantom diam memiliki dosis melebihi ambang batas yang ditetapkan.

The Intensity Modulated Proton Therapy (IMPT) technique is the most advanced technique in proton beam therapy. This is because IMPT can produce a dose distribution that is more appropriate to the target with a minimum dose in healthy organs. The use of radiotherapy for lung cancer cases has considerable challenges. This is due to the uncertainty of the range and movement of organs, which allows errors in planning to occur. 4 Dimension Computed Tomography (4DCT) is a technique that can provide temporal information on changes in healthy tissues and organs. Each phase generated from 4DCT, can provide information about the location, density, and volume of the target tissue and surrounding healthy organs. The use of all 4DCT planning phases in clinical practice has a very large workload, so one solution is to use only two extreme phases. This research was conducted by comparing the 10 planning phases using the IMPT technique. It aims to find out at what phase the best level of effectiveness is produced, based on the research data obtained. Evaluation was carried out based on the parameters of Conformity Index (CI), Gradient Index (GI), and Conformity Index (CI). The results of this study indicate that in the three parameters the best values ​​are in the two extreme phases. In the SFO and MFO techniques, the best CI value is in the 0% phase, while the HI value in the SFO technique is in the 50% phase and the MFO is in the 90% phase. In addition, for the GI value in both techniques, it is best to be in the 0% phase. "
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
<<   1 2 3 4 5 6 7 8 9 10   >>