Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 84 dokumen yang sesuai dengan query
cover
"The 2013 ASHRAE Handbook: Fundamentals covers basic principles and data used in the HVAC&R industry. Updated with research sponsored by ASHRAE and others, this volume includes 1,000 pages and 39 chapters covering general engineering information, basic materials, climate data, load and energy calculations, duct and pipe design, and sustainability, plus reference tables for abbreviations and symbols, I-P to SI conversions, and physical properties of materials."
Atlanta: ASHRAE, 2013
697ASHA001
Multimedia  Universitas Indonesia Library
cover
"Studi eksperimental yang dilakukan pada penelitian ini adalah untuk mengestimasi kemampuan ejektor dalam meningkatkan efisiensi energi dari sistem refrigerasi yaitu dengan melakukan modifikasi yang menempatkan ejektor sebagai piranti langkah kompresi kedua. Pengujian dilakukan terhadap dua macam siklus refrigerasi yaitu refrigerasi sistem konvensional dengan refrigerasi yang memanfaatkan ejektor sebagai kompresi kedua yang nanti akan dibandingkan untuk mengetahui karakteristik COP serta efisiensi energi masing-masing siklus. Adapun beban pendinginan yang dilakukan yaitu dengan mengatur temperatur Tin pada 30 oC, 35 oC, 40 oC dan 45oC. Hasil dari penelitian ini yaitu unjuk kerja yang diperoleh dari mesin AC untuk COP mengalami penambahan sebesar 0,814, kerja kompresor mengalami penurunan sebesar 5,284 kJ/kg, penghematan yang didapat sebesar 0,187 kW dan penambahan efisiensi 8%. Berdasarkan hasil eksperimen yang telah dilakukan maka dengan adanya penambahan piranti ejektor pada mesin AC dapat memberikan kinerja yang lebih baik dan penghematan energi dibandingkan dengan yang tidak mengunakan ejektor (konvensional)."
600 TEKNOSAINS 1:11 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
Christian
"Dalam aplikasinya di bidang industri, sistem refrigerasi tunggal dan bertingkat tidak mampu untuk mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dengan kalor yang akan dibuang, namun, tidak demikian dengan system cascade. Penelitian dengan alat yang sederhana yang dilakukan sebelumnya dengan menggunakan refrigeran alami telah menawarkan peluang yang baik.
Skripsi ini membahas tentang pengujian sistem cascade dengan menggunakan R22 pada high-stage (HS) dan R404A pada low-stage (LS). Untuk mendapatkan nilai performa optimum serta trend dari parameter yang mempengaruhinya dengan memvariasikan nilai tekanan discharge pada sistem HS. Proses variasi dilakukan dengan mengurangi sedikit demi sedikit massa refrigeran yang mengalir didalam sistem.
Dengan memvariasikan tekanan discharge pada sistem HS dari 13-16 bar didapatkan nilai temperatur evaporasi terendah sebesar -33°C serta COP cascade maksimum sebesar 1,79. Suhu terendah tercapai pada tekanan discharge 13,8 bar sedangkan COP cascade maksimum tercapai pada tekanan discharge 16 bar.

In many industrial applications, single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures and now cacscade system appear to be the best alternative. Modest research,in the past, has been done in cascaded sytem based on natural refrigerants thereby offering good potential for research.
In this paper, a cascaded system for simultenous heating and cooling with a R22 based high-stage (HS) cycle and R404A based low-stage (LS) cycle for simultenous refrigeration and heating application has been analyzed. To Facilate prediction of optimum performance parameter, performance trends with variation in the pressure of HS cycle have been presented. Variation processes done with releasing some refrigeran in the system trough a ventile.
The experimental results obtained by pressure variation from 13,8 to 16 bar is - 33°C for the lowest evaporating temperature and 1,79 for maksimum cascade COP. The lowest temperature reached in 13,8 bar and maksimum cascade COP in 16 bar.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37337
UI - Skripsi Open  Universitas Indonesia Library
cover
Andi Taufan
"Isu lingkungan mengenai pemanasan global dan penipisan ozon merupakan faktor pendorong inovasi ramah lingkungan. Oleh karena itu, dikembangkanlah alat pendingin adsorpsi menggunakan metanol yang ramah lingkungan sebagai refrigeran dan karbon aktif sebagai adsorben. Pada alat pendingin adsorpsi yang sedang dikembangkan Departamen Teknik Mesin Universitas Indonesia perlu untuk diketahui karakteritik proses adsorpsi dan efek pendinginannya. Pengujian dilakukan dengan menggunakan metanol sebanyak 250 ml sebagai gambaran awal performa adsorber pada proses adsorpsi selama 75 menit. Pada akhir proses didapatkan perubahan tekanan di evaporator sebesar 2 cmHg dan di adsorber sebesar 1,3 cmHg dengan rata-rata perbedaan tekanan antara keduanya selama 75 menit sebesar 4,6 cmHg. Temperatur terendah yang dicapai di evaporator sebesar 14°C yang dicapai setelah menit ke-65.

Environmental issues about global warming and ozone depleting are the factors stimulating green innovation. Therefore, adsorption refrigeration system has been developed with methanol as a green refrigerant and actived carbon as adsorbent. It is important to know the characteristics of the adsorpstion process and refrigeration effect of the machine that developed by Department of Machine Engineering, Universitas Indonesia. It is used 250 ml methanol as refrigerant during 75 minutes of experiment. At the end of adsorpstion process it is produce the pressure difference in evaporator about 2 cmHg and 1,3 cmHg in adsorber with mean pressure difference about 4,6 cmHg. The lowest temperature in evaporator is 14°C that reached after 65 minutes running."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50739
UI - Skripsi Open  Universitas Indonesia Library
cover
Bobi Wahyu Saputra
"Krisis energi dan pencemaran lingkungan adalah faktor yang mondorong para ilmuwan untuk menemukan inovasi pada sistem refrigerasi. Salah satunya pengembangan mesin pendingin adsorpsi. Mesin pendingin adsorpsi merupakan mesin refrigerasi yang memanfaatkan proses kompresi alami akibat dari fenomena adsorpsi. Sumber energi pada mesin pendingin adsopsi diperoleh dari panas gas buang hasil pembakaran. Sistem ini menggunakan metanol sebagai refrigeran yang memiliki karakteristik zero ozone depletion potential (ODP) dan zero global warming potential (GWP) . Sistem ini menggunakan karbon aktif sebagai adsorbennya.Mesin pendingin adsopsi dirancang untuk tidak mengalami kebocoran pada tekanan sampai dengan -76 cmHg gauge untuk mendapatkan temperatur saturasi methanol yang mencukupi untuk proses penyerapan kalor. Sedangkan material yang dipilih pada komponen mesin ini adalah material yang tahan terhadap korosi akibat metanol seperti tembaga dan stainless steel. Mesin pendingin adsorpsi ini dirancang dengan dua adsorber sehingga proses adsorpsi dan desorpsinya dilakukan secara continues.

Crisis of energy and the environmental contamination issue are the factors stimulating scientists to discover the innovation in refrigeration system. One of them through the development of adsorption refrigeration machine.Adsorption refrigeration machine is a refrigeration machine using natural compression process generated from adsorption phenomenon. Source of energy for adsorption refrigeration machine is from the heat which is generated by the gas of combustion.This refrigeration system use the methanol as a refrigerant which has zero ozone depletion potential (ODP) and zero global warming potential characteristic. This system is also using activated carbon as the adsorbent.This machine is designed to be able to prevent leakage at pressure up to -76 cmHg gauge to reach the saturation temperature which is enough for heat absorption process. While, material selected for component of this machine is a material that capable to resist the corrosion effect caused by methanol such as copper and stainless steel.This adsorption refrigeration machine is designed with two adsorber so that the process of adsorption and desorption are conducted as continous process."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50726
UI - Skripsi Open  Universitas Indonesia Library
cover
Dedeng Rahmat
"Dalam aplikasinya di bidang industri, sistem refrigerasi tunggal dan bertingkat tidak mampu untuk mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dengan kalor yang akan dibuang, namun, tidak demikian dengan sistem cascade. Penelitian dengan alat yang sederhana yang telah dilakukan sebelumnya dengan menggunakan refrigeran alami telah menawarkan peluang yang baik.
Skripsi ini membahas tentang pengujian sistem cascade dengan menggunakan dua macam refrigeran sebagai variasi di sisi bagian HS, sedangkan pada bagian LS, digunakan campuran refrigeran alami R170/R744. Pengujian dilakukan dengan tiga cara, yaitu : memvariasikan komposisi massa campuran R170/R744, memvariasikan bukaan katup ekspansion LS, serta memvariasikan jenis refrigeran pada sisi bagian HS. Temperatur evaporasi terrendah yang bisa dicapai oleh sistem ini adalah -69,7°C dengan COP sebesar 1,88. Dengan kondisi 700g R22 pada sisi bagian HS dan 100g R170 pada sisi bagian LS

In many industrial applications, single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures and now cascade system appear to be the best alternative. Modest reserch, in the past, has been done in cascade system based on natural refrigerants thereby offering good potential for research.
In this paper, a cascaded system for simultenous heating and cooling with a R22 and R290 based high-stage (HS) cycle and mixed R170/R744 based low-stage (LS) cycle for simultenous refrigeration and heating application has been analyzed. To facilate prediction of optimum performance parameter, performance trends with variation in fraction mass of R170/R744, variation in flow rate of ekspansion valve of LS, and variation refrigerant of HS have been presented. The lowest temperature reached in -69,7°C with COP 1,81. 700g of R22 (HS) and 100g of R170 (LS)
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50736
UI - Skripsi Open  Universitas Indonesia Library
cover
Napitupulu, Erwin
"The contents of fuel-oil are now running low and its prices are becoming more expensive that causes the supply of fuel-oil to the power station in PLN disturbed. Dimmed in district consecutively by the PLN is cause by this event.
Green Medical Box Portable is a storage for the vaccine and other medicine which doesn?t need to depend on electricity from PLN. Alternative source of electricity can be used from the sunlight (solar cell) and battery, so if there is any electricity failure then the temperature can still be obtained and the vaksin and other medicine always in good conditioning.
This Green Medical Box Portable have two storages. The volume of the first storage (freezer) is about 20,4 litre which temperature of storage is about - 15°C. Whereas the volume of second storage (cooler) is about 45,15 litre which temperature of storage is about 5°C.
The refrigeration system of Green Medical Box portable uses DC (Direct Curent) compressor from Danfoss with BD35K type. The refrigerant that used is R 600a."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50753
UI - Skripsi Open  Universitas Indonesia Library
cover
Donni Redford
"Penggunaan sistem refrigerasi cascade memungkinkan untuk mencapai temperatur yang sangat rendah. Pada dasarnya temperatur akan semakin rendah jika tekanan pada sistem lebih rendah. Namun pada temperatur yang lebih rendah tersebut, kinerja yang dihasilkan belum tentu yang terbaik.
Untuk mengetahui kinerja dari sistem refrigerasi dapat dilakukan dengan dua cara, yaitu dengan simulasi dan melalui eksperimen. Simulasi digunakan untuk memperkiraan kinerja sistem dengan membandingkan kinerja sistem yang menggunakan refrigeran yang berbeda. Sedangkan hasil aktual dari performa sistem diketahui melalui eksperimen yang akan dilakukan, namun dibatasi oleh jenis refrigeran yang digunakan. Pengujian ini dilakukan dengan menggunakan refrigeran R22 pada high-stage dan R404A pada low-stage.
Untuk mengetahui apakah suatu sistem sudah bekerja optimal atau tidak, perlu dilakukan variasi terhadap salah satu atau lebih variabel yang berhubungan. Salah satunya adalah dengan melakukan variasi terhadap tekanan. Variasi tersebut cukup dilakukan pada sistem low-stage dengan acuan pada tekanan discharge line. Pengujian dilakukan dengan 7 variasi dimulai dari 10,4 bar hingga 16,4 bar dengan selisih tiap 1 bar. Variasi ini dapat dilakukan dengan cara mengubah jumlah massa refrigeran, dengan tekanan yang berubah, maka parameter lain seperti temperatur, laju aliran massa, selisih entalpi kompresi, kapasitas refrigerasi mengalami perubahan. Temperatur low-stage evaporator akan menjadi lebih rendah pada tekanan yang lebih rendah, dan mencapai -35°C ketika tekanan lowstage discharge line mencapai 10,4 bar. Sementara nilai COP cenderung naikturun perlahan, dan nilai COP paling tinggi adalah 1,697, terjadi pada saat tekanan pada low-stage discharge line 13,4 bar.

The use of cascade refrigeration system make very low temperature is possible to reach. Basically, the temperature would be lower if the pressure in the system is lower. But at the lower temperature, the performance result is unsure to be the best.
To know the performance of refrigeration system can be done by two ways, that is with simulation and with experiment. Simulation used to predict the performance system by compare the system performance using different refrigerant. Whereas actual result of system performance known by doing experiment, but limited by the type of refrigerants which would be used. This test done by used refrigerant R22 in the high-stage and R404A in the low-stage.
To know if the system already optimal or not, variation is needed to one or more relative variable. One of them is to do variation toward pressure. That variation only need to be apply on low-stage system using discharge line pressure as a reference. The test done with using 7 variation start from 10,4 bar until 16,4 bar with a gap 1 bar each other. This variation can be done by change the amount of refrigerant mass, with different pressure, the other parameters like temperature, difference of compression entalphy, refrigeration capacity would be changed too. That changes make the system performance at different pressure would become different. The low-stage evaporator temperature would become lower at lower pressure, and reach -35°C when low-stage discharge line pressure reach 10,4 bar. Whereas COP value disposed to increase-decrease slowly, and the highest COP value is 1,697, it happened when the pressure of low-stage discharge line 13,4 bar.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37325
UI - Skripsi Open  Universitas Indonesia Library
cover
Taufiq Hidayat
"Green Medical Box adalah sebuah tempat untuk pendinginan obat-obatan, vaksin, darah dan organ dimana menggunakan refrigeran yang ramah lingkungan yaitu R600a. Sumber energi untuk Green Medical box ini bias menggunakan power supply 220 V AC / 12 V DC, batere atau solar panel. Pada tugas akhir ini pengujian hanya menggunakan sumber energi dari power supply 220 V AC / 12 V DC.
Green Medical Box ini terdiri dari 2 kabin yaitu kabin cooler dan kabin freezer. Untuk kabin cooler set point temperaturnya pada +5 °C dan kabin freezer -15 °C. Temperatur kabin diatur oleh dua solenoid yang masing-masing dipasang di liquid line sebelum masuk pipa kapiler, dimana buka tutupnya diatur oleh digital thermostat.
Pengujian Green Medical Box ini dilakukan dengan 3 tahapan percobaan yaitu pertama hanya cooler yang bekerja, kedua hanya freezer yang bekerja dan ketiga cooler dan freezer bekerja bersamaan. Untuk tahapan percobaan pertama dan kedua temperatur set point yang diinginkan tercapai, sedangkan tahapan ketiga saat cooler dan freezer bekerja bersamaan maka freezer hanya mampu mencapai temperatur kabin maksimum selama 1 jam sebesar -8.6 °C, sedangkan cooler pada saat awal temperaturnya turun kemudian menit berikutnya mengalami kenaikan temperatur karena refrigeran cenderung ke freezer sehingga evaporator cooler sedikit sekali terisi refrigeran ( kosong ).
Untuk penelitian salanjutnya penulis menyarankan untuk memakai EPR (evaporator pressure regulator) yang diletakan setelah evaporator cooler untuk mempertahankan tekanan suction nya. Juga jika temperatur set point yang diinginkan belum tercapai saat cooler dan freezer bekerja bersamaan maka hendaknya memperbesar kapasitas kompresor.

Green Medical Box is a storage for refrigeration the medicines, vaccines, blood plasma and organ using friendly environment refrigerant such as R600a. The power of the Green medical Box can uses power supply 220 V AC / 12 V DC, battery or solar panel. This final project only use power supply 220 V AC / 12 V DC.
This Green Medical Box consist of 2 cabin (cooler cabin and freezer cabin). The set point temperature cooler cabin is +5 °C and freezer cabin is -15 °C. Cabin temperature controlled with solenoid each put liquid line before capillary tube. Open close of the selenoid controlled with digital thermostat.
Testing of Green Medical Box have 3 stage: first only cooler ON, second only freezer ON, third Cooler & freezer ON. The first & second stage the set point temperature is attainable. For the third stage, the temperature of freezer during one hour have -8.6 °C, whereas the cooler temperature begining decrease but the next time increase because the refrigerant much to freezer compare to cooler. So the cooler evaporator have little refrigerant.
For the next riset the writer to suggest use EPR (evaporator pressure regulator). Location of EPR after evaporator cooler for holding of suction pressure. If temperature not attainable for third stage, the capacity of compresor must be larger.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S38085
UI - Skripsi Open  Universitas Indonesia Library
cover
Aris Muhammad HS
"Menipisnya kandungan bahan bakar fosil serta naiknya harga BBM mengakibatkan pasokan BBM ke pembangkit listrik di PLN sering terganggu. Hal ini berdampak sering terjadi pemadaman secara bergantian oleh PLN.
Green Medical Box Portable merupakan kotak penyimpan vaksin dan obatobatan lainnya yang tidak terlalu tergantung dengan energi listrik dari PLN. Alternatif sumber energi listrik yang digunakan berasal dari cahaya matahari (solar panel) dan batere, sehingga apabila terjadi pemadaman listrik dari PLN, maka vaksin dan obat-obatan lainnya di dalam Green Medical Box tetap dijaga temperaturnya sesuai dengan yang diinginkan.
Green Medical Box Portable mempunyai dua tempat penyimpanan, penyimpanan pertama (freezer) dengan volume + 20,4 liter untuk vaksin dengan temperature penyimpanan ? 15°C. Sedangkan tempat penyimpanan kedua (cooler) dengan volume + 45,15 liter untuk vaksin dengan tempeatur penyimpanan 5 °C.
Untuk sistem refrigerasinya, Green Medical Box Portable menggunakan kompresor DC dari Danfoss dengan tipe BD35K. Refrigeran yang digunakan adalah R 600a.

The contents of fuel-oil are now running low and its prices are becoming more expensive that causes the supply of fuel-oil to the power station in PLN disturbed. Dimmed in district consecutively by the PLN is cause by this event.
Green Medical Box Portable is a storage for the vaccine and other medicine which doesn?t need to depend on electricity from PLN. Alternative source of electricity can be used from the sunlight (solar cell) and battery, so if there is any electricity failure then the temperature can still be obtained and the vaksin and other medicine always in good conditioning.
This Green Medical Box Portable have two storages. The volume of the first storage (freezer) is about 20,4 litre which temperature of storage is about ? 15 °C. Whereas the volume of second storage (cooler) is about 45,15 litre which temperature of storage is about 5 °C.
The refrigeration system of Green Medical Box portable uses DC (Direct Curent) compressor from Danfoss with BD35K type. The refrigerant that used is R 600a.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37349
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9   >>