Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 179860 dokumen yang sesuai dengan query
cover
Lathifah Hana Gusti
"Antimicrobial Resistance (AMR) menyebabkan penurunan efektivitas pengobatan dan dapat dideteksi dengan keberadaan Antibiotik Resistance Genes (ARG) seperti blaCTX-M yang paling banyak ditemukan dan memberikan resistansi terhadap antibiotik sefotaksim. Hingga saat ini, belum ada penelitian yang bertujuan untuk mendeteksi keberadaan gen blaCTX-M pada Sungai Bekasi. Penelitian ini bertujuan untuk menganalisis konsentrasi bakteri Escherichia coli non-selektif dan resistan pada hilir Sungai Bekasi, menganalisis keberadaan ARG blaCTX-M pada bakteri E. coli tersebut, serta memberikan rekomendasi lokasi sampling bakteri E. coli untuk mendeteksi AMR. Metode Polymerase Chain Reaction pada penelitian ini digunakan untuk mengamplifikasi DNA dan dilanjutkan dengan elektroforesis untuk pembacaan ukuran DNA. Berdasarkan hasil penelitian, hilir Sungai Bekasi memiliki rata-rata konsentrasi bakteri E. coli non-selektif sebesar 261 CFU/mL dengan titik sampling 1/3 dari pinggir sungai dan sebesar 207 CFU/mL dengan titik sampling di pinggir sungai. Sedangkan, rata-rata konsentrasi bakteri E. coli resistansi antibiotik sefotaksim sebesar 26 CFU/mL dengan titik sampling 1/3 dari pinggir sungai dan sebesar 20 CFU/mL dengan titik sampling di pinggir sungai. Rasio perbandingan bakteri E. coli resisten antibiotik dengan bakteri E. coli non-selektif adalah 9,78% dengan titik sampling 1/3 dari pinggir sungai dan 9,27% dengan titik sampling di pinggir sungai. Hasil penelitian mendapatkan bahwa adanya keberadaan gen resistansi antibiotik blaCTX-M pada hilir Sungai Bekasi sebanyak 80% dari sampel yang diambil. Dimana gen yang mendominasi adalah CTX-M grup 1 yang beranggotakan gen CTX-M-1, CTX-M-3, dan CTX-M-15. Hasil penelitian juga menunjukan bahwa sampel dari pinggir sungai memiliki hasil yang lebih homogen dan lebih mudah untuk dilakukan.

Antimicrobial Resistance (AMR) causes a decrease in the effectiveness of treatment and can be detected by the presence of Antibiotic Resistance Genes (ARG) such as blaCTX-M which is the most commonly found and provides resistance to the antibiotic cefotaxime. Until now, there has been no research aimed at detecting the presence of the blaCTX-M gene in the Bekasi River. This study aims to analyze the concentration of non-selective and resistant Escherichia coli bacteria at downstream of the Bekasi River, analyze the presence of ARG blaCTX-M in the E. coli bacteria, and provide recommendations for sampling locations for E. coli bacteria to detect AMR. The Polymerase Chain Reaction method in this study was used to amplify DNA and was followed by electrophoresis to read the size of the DNA. Based on the research results, the downstream Bekasi River has an average concentration of non-selective E. coli bacteria of 261 CFU/mL with a sampling point 1/3 from the riverbank and 207 CFU/mL with a sampling point on the riverbank. Meanwhile, the average concentration of cefotaxime-resistant E. coli bacteria was 26 CFU/mL with a sampling point of 1/3 from the riverbank and 20 CFU/mL with a sampling point on the riverbank. The ratio of antibiotic resistant E. coli bacteria to non-selective E. coli bacteria was 9.78% with a sampling point of 1/3 from the riverbank and 9.27% with a sampling point on the riverbank. The results of the study found that the presence of the blaCTX-M antibiotic resistance gene in the downstream of the Bekasi River was as much as 80% of the samples taken. Where the dominant gene was CTX-M group 1 consisting of the CTX-M-1, CTX-M-3, and CTX-M-15. The results of the study also shown that samples from the riverbank have more homogeneous results and are easier to carry out.
"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Diky Fahrul Rozy
"Antimicrobial Resistance Bacteria (AMRB) adalah kondisi di mana bakteri, parasit, virus atau jamur penyebab infeksi menjadi kebal terhadap obat yang digunakan untuk mengobati infeksi. Extended Spectrum Beta-Lactamase producing E. coli (ESBL-Ec) termasuk salah satu contoh bakteri yang mampu menghasilkan enzim yang membuatnya resistan terhadap banyak antibiotik yang umum digunakan. Berdasarkan hal tersebut WHO telah menetapkan pengawasan global tricyle project yang berfokus pada ESBL-Ec. Salah satunya adalah Sungai Ciliwung pada bagian hilir dimana lokasi tersebut merupakan kawasan padat penduduk, perbelanjaan, dan perdagangan terbesar di Jakarta Utara. Penelitian ini bertujuan untuk menganalisis konsentrasi E. coli, konsentrasi ESBL-Ec, rasio konsentrasi serta mengkarakterisasi gen terhadap antibiotik cefotaxime (blaCTX-M) pada E. coli. Metode yang digunakan pada penelitian ini menggunakan direct one-step spread plate method menggunakan media Tryptone-Bile-X-Glucuronide (TBX) agar, dilakukan pengujian secara fenotipe Antimicrobial Susceptibility Test (AST) dengan metode Double Disk Synergy Test (DDST). Serta, mengkarakterisasi gen ESBL blaCTX-M dengan metode multiplex Polymerase Chain Reaction (PCR) kemudian divisualisasikan menggunakan elektroforesis. Hasil pengujian menunjukkan konsentrasi E. coli untuk sampel hilir A sebesar sebesar (1,3 ± 0,02) × 105 CFU/100 mL dengan konsentrasi ESBL-Ec sebesar (3,5 ± 1,09) × 104 CFU/100 mL. Sedangkan, konsentrasi E. coli untuk sampel hilir B sebesar (0,9 ± 0,18) × 105 CFU/100 mL dengan konsentrasi ESBL-Ec sebesar (4,1 ± 0,3) × 104 CFU/100 mL. Hasil rasio ESBL-Ec pada hilir Sungai Ciliwung di titik hilir A sebesar 26,48%, sedangkan rasio ESBL-Ec pada hilir B sebesar 45,83%. Rasio ini masuk kategori yang tinggi dimana jika dibandingkan dengan RAN-PRA sebesar 14% untuk sektor lingkungan. Berdasarkan hasil karakterisasi gen terdeteksi gen positif blaCTX-M  sebanyak 9 dari 10 sampel (90%) pada titik hilir A. Sedangkan untuk titik hilir B terdeteksi gen positif blaCTX-M  sebanyak 10 dari 10 sampel (100%). Semua sampel yang terdeteksi isolat penghasil EBL merupakan jenis blaCTX-M grup 1 dimana gen tersebut terdiri atas jenis gen blaCTX-M-1, gen blaCTX-M-3, dan gen blaCTX-M-15. Berdasarkan prevalensi konsentrasi ESBL-Ec pada titik hilir Sungai Ciliwung menjadi isu-isu yang penting terhadap pencemaran lingkungan oleh AMRB. Perlu adanya tindakan pencegahan penyebaran ESBL-Ec dengan melakukan peningkatan personal higiene dan manajemen air bersih, peningkatan kontrol penggunaan dan pengawasan antibiotik, penegakkan penjualan antibiotik illegal di e-commerce, perketatan dan kebijakan usaha dalam pembuangan limbah industri, dan peningkatan cakupan pelayanan IPAL domestik.

Antimicrobial Resistance Bacteria (AMRB) is a condition in which infection-causing bacteria, parasites, viruses or fungi become resistant to the drugs used to treat the infection. Extended Spectrum Beta-Lactamase producing E. coli (ESBL-Ec) is one example of a bacterium capable of producing an enzyme that makes it resistant to many commonly used antibiotics. Based on this, WHO has established a global surveillance tricyle project that focuses on ESBL-Ec. One of them is the Ciliwung River at the downstream where the location is the largest densely populated, shopping and trading area in North Jakarta. This study aims to analyze the concentration of E. coli, ESBL-Ec concentration, concentration ratio and characterize genes against cefotaxime antibiotics (blaCTX-M) in E. Coli. The method used in this study was one-step spread plate method using Tryptone-Bile-X-Glucuronide (TBX) agar media, phenotypically testing Antimicrobial Susceptibility Test (AST) with Double Disk Synergy Test (DDST) method. Also, characterize the ESBL blaCTX-M gene by multiplex Polymerase Chain Reaction (PCR) method and then visualized using electrophoresis. The test results showed E. coli concentration for downstream sample A of (1,3 ± 0,02) × 105 CFU/100 mL with ESBL-Ec concentration of (3,5 ± 1,09) × 104 CFU/100 mL. Meanwhile, the average E. coli concentration for downstream B samples was (0,9 ± 0,18) × 105 CFU/100 mL with ESBL-Ec concentration of (4,1 ± 0,3) × 104 CFU/100 mL. The results of the ESBL-Ec ratio in the downstream Ciliwung River at downstream point A amounted to 26.48%, while the ESBL-Ec ratio in downstream B amounted to 45.83%. This ratio is categorized as high when compared to the RAN-PRA of 14% for the environmental sector. Based on the results of gene characterization, the blaCTX-M positive gene was detected in 9 out of 10 samples (90%) at downstream point A. As for the downstream point B, positive blaCTX-M genes were detected in 10 out of 10 samples (100%). All samples detected EBL-producing isolates are group 1 blaCTX-M types where the gene consists of the blaCTX-M-1 gene, blaCTX-M-3 gene, and blaCTX-M-15 gene. Based on the prevalence of ESBL-Ec concentrations at the downstream point of the Ciliwung River, it becomes an important issue for environmental pollution by AMRB. Improved personal hygiene and clean water management, improved antibiotic use control and surveillance, enforcement of illegal antibiotic sales in e-commerce, tightening and business policies in industrial waste disposal, and increasing the coverage of domestik WWTP services.
"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Seven antibiotics including norfloxacin (NOR) were tested via disk susceptibility test on E. coli
culture isolated from the MLSS of the two types of lab-scale sequencing batch reactors (SBR), a
common SBR and an SBR with rnicrofiltration membrane (SB-MBR) for treatment of synthetic
municipal wastewater. The same experiment treating the NOR-added wastewater to examine the
possible induction of resistance to itself and the other antibiotics. The MLSS from Bangl
culture (TISTR780) were spiked daily into both reactors. The reactors were continuously operated
under 2hr/2hr of aeration/non-aeration cycle and resistances to antibiotics of E. coli in MLSS were
monitored. When NOR was not added, the SB-MBR showed lower percentages of resistant E. coli
than the SBR did to amoxicillin/clavulanic acid, amikacin, nalidixic acid, tetracycline and
chloramphenicol. Oppositely, the SB-MBR treating the NOR-added wastewater appeared to
promote resistances of E. coli to nalidixic acid, sulfamethoxasole and tetracycline probably due to a
long SRT and low DO compared to that of SBR. Although its mechanism should be analyzed with
molecular techniques in further studies, this NOR-induced expression of resistance resulted in a
higher occurrence of multidrug resistant E. coli in the SB-MBR than that in the SBR."
AEJ 4:1 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
M. Afif Hasnan
"Ketersediaan air bersih yang aman dan sehat menjadi tantangan utama dalam memastikan keberlanjutan kehidupan manusia dan ekosistem di sekitarnya. Penelitian ini mengangkat permasalahan kualitas air danau, khususnya Danau Mahoni di Kampus Depok Universitas Indonesia, yang terpapar oleh tingkat pencemaran bakteri Escherichia coli yang melebihi standar keamanan air. Melalui pemodelan sistem dinamis, penelitian ini bertujuan untuk menganalisis konsentrasi eksisting pencemaran bakteri E. Coli, menyimulasikan model dinamis konsentrasi bakteri, dan menyusun strategi intervensi untuk meningkatkan kualitas air danau tersebut. Metode pengambilan sampel air akan dilakukan berdasarkan SNI 9063:2022 dan pengujian sampel Bakteri E. Coli dilakukan menggunakan metode Total Plate Count dengan media Triptone Bile X-Glucuronida. Model akan disimulasikan menggunakan aplikasi Vensim PLE. Hasil pengujian laboratorium menunjukkan konsentrasi bakteri E. Coli pada Danau Mahoni berada pada rentang 1,0 x 103 hingga 1,003 x 105 CFU/100 ml. Hasil simulasi kondisi eksisting menunjukkan konsentrasi bakteri E. Coli pada Danau Mahoni pada rentang 2,05 x 102 hingga 1,9 x 105 CFU/100 ml dengan nilai validasi MAPE sebesar 7% untuk segmen 1 (kategori sangat baik), 13% untuk segmen 2 (kategori baik), dan 18% untuk segmen 3 dan masuk kedalam kategori baik. Terdapat dua strategi intervensi perbaikan kualitas pencemaran bakteri E. Coli yaitu dengan pembangunan IPAL dan pembuatan Disinfeksi Ultraviolet pada kedua kanal inlet danau.

The availability of clean and safe water presents a major challenge in ensuring the sustainability of human life and surrounding ecosystems. This research addresses the issue of water quality in lakes, particularly Lake Mahoni at the University of Indonesia's Depok Campus, which is exposed to levels of Escherichia coli (E. coli) bacteria pollution that exceed water safety standards. Through dynamic system modeling, this research aims to analyze the existing concentration of E. coli bacterial contamination, simulate a dynamic model of bacterial concentration, and develop intervention strategies to improve the water quality of the lak. Water sampling will be conducted according to SNI 9063:2022 standards, and E. coli bacteria testing will be performed using the Total Plate Count method with Triptone Bile X-Glucuronida media. The model will be simulated using the Vensim PLE application. Laboratory test results show that the concentration of E. Coli bacteria in Lake Mahoni is in the range of 1.0 x 103 to 1.003 x 105 CFU/100 ml. Simulation results of existing conditions show that the concentration of E. Coli bacteria in Lake Mahoni is in the range of 2.05 x 102 to 1.9 x 105 CFU/100 ml with MAPE validation values of 7% for segment 1(very good category), 13% for segment 2 (good category), and 18% for segment 3 and included in the good category. There are two intervention strategies to improve the quality of E. Coli bacterial contamination, namely by constructing an IPAL and constructing Ultraviolet Disinfection in the two inlet canals of Lake Mahoni."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Azzahra Sophie Larasati
"Resistensi terhadap antibiotik pada bakteri dan penyebarannya di lingkungan menjadi ancaman terhadap kesehatan masyarakat. Keberadaan bakteri resisten terhadap antibiotik dipicu oleh aktivitas antropogenik, salah satunya adalah penyalahgunaan antibiotik. Bakteri resisten terhadap antibiotik yang ditemukan di lingkungan domestik dapat menimbulkan risiko kesehatan pada warga setempat. Penelitian ini dilakukan untuk mengetahui konsentrasi bakteri E. coli resisten di lingkungan domestik di Kota Bekasi, menilai risiko kesehatan yang ditimbulkan akibat paparan mikroorganisme, dan mengidentifikasi rute paparan bakteri E. coli resisten terhadap antibiotik ke manusia. Identifikasi konsentrasi bakteri E. coli resisten terhadap antibiotik menggunakan kultur bakteri dan penilaian risiko dilakukan menggunakan metode Quantitative Microbial Risk Assessment (QMRA). Hasil penelitian menunjukkan rata-rata konsentrasi bakteri E. coli resisten terhadap antibiotik (n=3) di tanah sebesar 1,28  105 CFU/mL, air sungai sebesar 3,9  101 CFU/mL, tangki septik sebesar 8,06  102 CFU/mL, feses ayam sebesar 1,33  106 CFU/mL, sedangkan di air tanah tidak ditemukan keberadaan E. coli resisten terhadap antibiotik. Penilaian risiko dengan metode QMRA pada bakteri E. coli resisten terhadap antibiotik dilakukan pada galur E. coli O157:H7 sebagai galur yang paling umum menyebabkan penyakit diare pada manusia. Probabilitas infeksi harian (Pinf,d) yang disebabkan oleh bakteri E. coli O157:H7 di tanah berkisar antara 33,37% - 36,99% sesuai kelompok usia dengan probabilitas infeksi tahunan (Pinf,a) 100% dengan probabilitas munculnya penyakit (Pill) sebesar 25%. Sementara itu, probabilitas infeksi harian (Pinf,d) yang disebabkan oleh bakteri E. coli O157:H7 di air sungai berkisar antara 4,88% - 14,28% dengan probabilitas infeksi tahunan (Pinf,a) 99% - 100% dan probabilitas munculnya penyakit (Pill) adalah 24,9% - 25% tergantung jenis ingestinya. Berdasarkan penilaian risiko tersebut, rute paparan bakteri E. coli resisten terhadap antibiotik ke manusia melalui media tanah dan air sungai, sehingga pencegahan dapat dilakukan untuk menangani risiko kesehatan pada manusia seperti meminimalisir penggunaan air sungai untuk aktivitas domestik, peningkatan fasilitas sanitasi, dan penerapan teknologi atau metode pencegahan resistensi terhadap antibiotik.

The occurrence of antibiotic-resistant bacteria in the environment is a threat to public health. The spread of antibiotic-resistant bacteria in the environment is influenced by anthropogenic activities, such as antibiotic misuse. Antibiotic-resistant bacteria found in the domestic environment pose a health risk to inhabitants. This study aims to identify antibiotic-resistant E. coli concentration in a domestic environment in Bekasi City, assess public health risks associated with exposure to pathogenic bacteria, and identify the exposure route of antibiotic-resistant E. coli to humans. The bacterial culture method was used to identify the concentration of antibiotic-resistant E. coli and the risk assessment was carried out using Quantitative Microbial Risk Assessment (QMRA). The results showed the average concentration of antibiotic-resistant E. coli (n=3) found in soil was 1,28  105 CFU/mL, in river water was 3,9  101 CFU/mL, in septic tank effluent was 8,06  102 CFU/mL, chicken feces was 1,33  106 CFU/mL, and none found in groundwater. Risk assessment was carried out using QMRA on E. coli O157:H7 strain as the most common strain to cause diarrheal illness in humans. The daily probability of infection (Pinf,d) caused by E. coli O157:H7 in soil ranged from 33,37% - 36,99% according to the age group with an annual probability of infection of 100% and the probability of illness obtained was 25%. Furthermore, the daily probability of infection caused by E. coli O157:H7 in river ranging from 4,88% - 14,28% with annual probability of infection (Pinf,a) ranged from 99% - 100% depending on the types of ingestion with the probability of illness obtained ranged from 24,9% - 25%. Based on the risk assessment, the exposure route of antibiotic-resistant E. coli can be determined by involving human, animal, and environmental sectors. Routes help to identify prominent exposure pathways in posing health risks to humans. The study revealed the route of antibiotic-resistant E. coli contamination to humans through environmental matrices, such as soil and river. Therefore, prevention can be done in order to deal with human health risks, such as reducing domestic uses of river water for communities, improving sanitation facility, and the application of technology and prevention methods to combat antibiotic resistance."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rioneli Ghaudenson
"Penelitian ini bertujuan untuk menguji kinerja kombinasi metode ozonasi dan kavitasi hidrodinamika dengan pelat berlubang dalam proses desinfeksi bakteri E.coli. Pada penelitian ini, dilakukan variasi dosis ozon, laju alir sirkulasi, dan metode disinfeksi. Ozon diproduksi menggunakan ozonator komersial dengan dosis ozon 64,83 mg/jam, 108,18 mg/jam, dan 135,04 mg/jam sementara kavitasi dibangkitkan menggunakan pelat berlubang. Metode desinfeksi yang akan divariasikan pada percobaan ini adalah: kavitasi hidrodinamika, ozonasi, dan gabungan keduanya. Hasil terbaik pada masing-masing metode didapatkan pada menit ke-60 dan laju alir sirkulasi 7 L/menit.
Metode gabungan kavitasi dan ozonasi mampu mendesinfeksi hingga 0 CFU/mL dari konsentrasi awal 2,10 x 105 CFU/mL. Metode ozonasi tunggal mampu mendesinfeksi bakteri E.coli hingga 0 CFU/mL dari konsentrasi awal 1,32 x 105 CFU/mL selama 60 menit. Metode kavitasi hidrodinamik memberikan hasil penyisihan paling sedikit, yaitu 5,20 x 104 CFU/mL dari konsentrasi awal 2,17 x 105 CFU/mL. Disimpulkan bahwa metode kombinasi menghasilkan desinfeksi bakteri E.coli yang lebih cepat dan lebih baik dibandingkan metode tunggalnya.

This research aims to evaluate the performance of hybrid method of ozonation and hydrodynamic cavitation with orifice plate on E.coli bacteria disinfection. Ozone dose, circulation flowrate, and disinfection method were varied. Ozone was produced by commercial ozonators with ozone dose of 64,83 mg hour, 108,18 mg hour, and 135,04 mg hour. Meanwhile, hydrodynamic cavitation was generated using an orifice plate. The disinfection methods compared in this research are hydrodynamic cavitation, ozonation, and the combination of both. The best result on each method was achieved on the 60th minutes and with a circulation flowrate of 7 L min.
The hybrid method attained final concentration of 0 CFU mL from the initial concentration of 2,10 x 105 CFU mL. The ozonation method attained final concentration of 0 CFU mL from the initial concentration of 1,32 x 105 CFU mL. Cavitation method gives the least elimination with final concentration of 5,20 x 104 CFU mL from the initial concentration of 2,17 x 105 CFU mL. In conclusion, hybrid method gives a faster and better disinfection of E.coli than each method on its own.
"
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67885
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fitri Amalia
"Penelitian ini mengkombinasikan metode ozonasi dan kavitasi hidrodinamikka dengan injektor venturi. Tujuan dari penelitian ini yaitu untuk mengetahui signifikansi kinerja dari penggabungan metode ozonasi dan kavitasi hidrodinamika terhadap proses desinfeksi bakteri Escherichia coli. Untuk mencapai tujuan tersebut dilakukan desinfeksi dengan metode ozonasi tunggal dan kavitasi tunggal sebagai pembanding. Variasi yang dilakukan adalah laju alir yaitu 3, 5 dan 7 L/menit dan dosis ozon 64,83, 108,18 dan 135,04 mg/jam. Metode kombinasi ozonasi dan kavitasi hidrodinamika laju alir 7 L/menit dan dosis ozon 135,04 mg/jam menghasilkan kinerja terbaik dengan konsentrasi awal sebesar 1,49 x 105 CFU/mL, semua bakteri dapat terdesinfeksi selama 45 menit. Hasil tersebut lebih baik dibandingkan metode kavitasi hidrodinamika tunggal laju alir 7 L/menit dengan bakteri tersisa sebesar 21 dan semua bakteri terdesinfeksi pada metode ozonasi tunggal dengan dosis ozon 135,04 mg/jam selama 60 menit.

This research combine ozonation and cavitation hydrodynamic methods with venturi injector. The purpose of this research is to observe significance of ozonation and hydrodynamic cavitation method to disinfection process of Escherichia coli bacteria. To achieve these objectives, disinfection process with single ozonation and single cavitation method was used as a comparison. The variations being used are flowrate 3, 5, 7 L min and dosage of ozone 64.83, 108.18 and 135.04 mg h. Combination of ozonation and hydrodynamic cavitation 7 LPM and 135.04 mg h dosage of ozone showed the best performance with initial concentration is 1.49 x 105 CFU mL, all bacteria were disinfected for 45 minutes. The results is better than the single hydrodynamic cavitation method 7 LPM which had 21 remaining of bacteria and all bacteria were disinfected on a single ozonation method 135.04 mg h dosage of ozone for 60 min."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67211
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arma Oktaviani
"Bakteri resisten antibiotika (Antimicrobial resistance, AMR) adalah salah satu dari 10 permasalahan kesehatan masyarakat global teratas. Di Indonesia, sedikit yang mengetahui tentang prevalensi E. coli penghasil Extended Spectrum Beta Lactamase (ESBL) di lingkungan dapat meningkatkan risiko kontaminasi sumber air tanah karena potensi kolonisasi yang cepat melalui mekanisme horizontal gene transfer (HGT). Penelitian ini bertujuan untuk mengetahui signifikansi variasi musim dalam pencemaran AMR, mengetahui jumlah AMR pada sumber fekal, menganalisis korelasi AMR dengan air tanah setempat, dan mengidentifikasi strategi pencegahannya. Studi validasi dengan modifikasi IDEXX Tray telah dilakukan untuk menguji dugaan E. coli penghasil ESBL (AMR E. coli) pada musim hujan (Maret 2020). Hasil penelitian menunjukkan bahwa 33,3% (n=60) sampel air tanah positif resisten terhadap antibiotika sefotaksim. Pada penelitian musim kemarau ini, 22,2% (n=54) sampel air tanah positif resistensi antibiotika sefotaksim dengan uji perbandingan variasi musiman menunjukkan perbedaan yang signifikan pada cemaran E. coli (p-value 0,045), tetapi tidak pada cemaran AMR E. coli (p-value 0,234). Pada perbandingan sumber air yang sama di kedua musim (n=45) didapatkan kontaminasi AMR di musim hujan juga lebih tinggi (33,3%) dibandingkan dengan musim kemarau (26,7%). Namun pada uji statistik berpasangan tidak ada perbedaan signifikan hasil nilai AMR di kedua musim. Uji AMR E. coli pada sumber fekal menunjukkan rata-rata jumlah AMR E. coli pada feses ayam adalah 4,36 x 106 MPN/100 mL sedangkan pada efluen tangki septik sebanyak 5,23 x 105 MPN/100 mL. Jika dibandingkan hanya pada sumber air yang menggunakan sumber air lokal (n=34), 8 dari 10 sampel yang positif AMR E. coli menggunakan tipe sanitasi setempat dan 4 dari 10 sampel yang positif AMR E. coli memiliki hewan ternak. Hubungan korelasi pencemaran AMR E. coli pada sumber air dianalisis berdasarkan faktor penggunaan sanitasi setempat dan kepemilikan hewan. Hasilnya didapatkan korelasi yang signifikan (p-value 0,041) karena penggunaan sanitasi setempat tetapi tidak ada hubungan antara kepemilikan ternak (p-value 0,891). Oleh karena itu, diperlukan strategi pengelolaan yang difokuskan pada pengurangan E. coli pada sumbernya untuk mendukung penyediaan air yang aman khususnya dari fenomena AMR di lingkungan.

Antimicrobial resistance (AMR) is one of the top 10 global public health problems. In Indonesia, little is known about the prevalence of Extended-Spectrum Beta-Lactamase (ESBL)-producing E. coli in the environment increases the risk of contamination of groundwater sources because of the potential for rapid colonization due to the potential for rapid colonization through horizontal gene transfer (HGT) mechanisms. This study aims to determine the significance of seasonal variations in AMR contamination, determine the amount of AMR in faecal sources, analyze the correlation of AMR with local groundwater, and identify prevention strategies. A validation study with a modified IDEXX tray has been carried out to test the suspicion of ESBL-producing E. coli (AMR E. coli) in the rainy season (March 2020). The results showed that 33.3% (n=60) of the groundwater samples were positive for resistance to the antibiotic cefotaxime. In this dry season, 22.2% (n=54) of groundwater samples is positive for cefotaxime antibiotic resistance. The comparison test of seasonal variation showed a significant difference in E. coli contamination (p-value 0.045), but not in AMR E. coli (p-value 0.234). Comparing to the same water source in both seasons (n=45), it was found that AMR contamination in the rainy season was also higher (33.3%) compared to the dry season (26.7%). However, in the paired statistical test there was no significant difference in the results of the AMR values ​​in the two seasons. The AMR E. coli test on faecal sources showed that the average amount of AMR E. coli in chicken faeces was 4.36 x 106 MPN/100 mL, while in the septic tank effluent it was 5.23 x 105 MPN/100 mL. When compared only to water sources using local water sources (n=34), 8 out of 10 samples positive for AMR E. coli used local sanitation types and 4 out of 10 samples positive for AMR E. coli owned livestock. The correlation between AMR E. coli contamination in water sources was analyzed based on factors of local sanitation use and animal ownership. The results obtained a significant correlation (p-value 0.041) due to the use of local sanitation but no relationship between livestock ownership (p-value 0.891). Therefore, a management strategy is needed that focuses on reducing E. coli at the source to support the provision of safe water, especially from the AMR phenomenon in the environment."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Simangunsong, Bellini
"ABSTRAK
Escherichia coli merupakan bakteri yang dapat menimbulkan gangguan kesehatan pada sistem pencernaan manusia. Gangguan tersebut biasanya disebut sebagai penyakit bawaan makanan foodborne disease . Tujuan penelitian ini adalah untuk mengetahui hubungan fasilitas sanitasi kantin dengan kontaminasi Escherichia coli pada makanan di kantin Universitas X tahun 2015. Penelitian ini menggunakan desain studi cross sectional potong-lintang , dengan sumber data sekunder penelitian Susanna et al tahun 2015 mengenai ldquo;Penelitian Sanitasi Laik dan Hygiene pada Makanan dan Minuman yang Dijajakan di Kantin Universitas X Tahun 2015 rdquo;. Sampel diambil dari 16 lokasi Universitas dengan jumlah 80 sampel. Variabel independen yang diamati yaitu sarana air bersih, pembuangan air limbah, toilet, tempat sampah, tempat cuci tangan, tempat mencuci peralatan, tempat mencuci bahan makanan, dan peralatan pencegah masuknya serangga dan tikus. Sedangkan variabel dependen adalah kontaminasi makanan oleh E. coli. Hasil penelitian ini menunjukkan bahwa sampel makanan yang terkontaminasi sebanyak 58,8 n=47 . Hasil bivariat menunjukkan nilai - p melebihi angka 0,05. Dengan demikian, hipotesis penelitian ditolak yang berarti semua fasilitas sanitasi tidak memiliki hubungan yang signifikan dengan kontaminasi E. coli pada makanan. Hasil penelitian ini menyarankan bahwa pihak PK3L hendaknya melakukan pengawasan rutin terhadap kualitas bakteriologis pada makanan maupun minuman yang dijual serta peneliti selanjutnya melakukan pemeriksaan E. coli terhadap sampel usap alat makanan, sampel usap alat masak, sampel air dan usap dubur.

ABSTRACT
Escherichia coli is a bacteria that can caue health problems in the human digestive system. The purpose of this study is to determine the correlation of sanitation facilities and contamination of E. coli on food in canteen of University X. Design of this study is cross sectional by using secondary data from Susanna et al research ldquo Sanitation and Hygiene on Food and Beverage being Served at Cafeteria of University 2015 rdquo . Samples were taken from 16 locations with 80 sample. Independent variables were clean water facilitation, sewage disposal, toilet, garbage container, hand washing facility, utensils washing facility, food washing facility, and insect and mouse prevention equipment. The dependent variable is food contamination by E. coli. The result of this study indicate that 58,8 n 47 of foods was contaminated. Bivariate analysis shows p value which is more than 0,05. Therefore, the research hypothesis is rejected which means that all sanitation facilities have no relationships to contamination of E. coli. This study suggests PK3L to do routine examination for bacteriological quality on food and beverages and the next reseacher to investigate E. coli on foodstuff swab samples, cooking swab samples, water samples and rectal swab."
2017
S69311
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sergie
"Kombinasi metode ozonasi dan kavitasi ultrasonik diketahui dapat digunakan sebagai alternatif desinfeksi bakteri Escherichia coli. Ozon diketahui dapat menyerang membran sel bakteri dan kavitasi ultrasonik meningkatkan perpindahan massa ozon ke sistem. Variabel penelitian yang diamati seperti intensitas gelombang 30 , 60 dan 100, dosis ozon 84 mg/jam, 157 mg/jam dan 231 mg/jam dan kombinasi keduanya diamati kemampuannya dalam mendesinfeki E.coli. Intensitas gelombang 100 dan konsentrasi ozon 231 mg/jam menghasilkan proses desinfeksi yang terbaik pada kondisi masing-masing, sehingga gabungan keduanya dipilih dalam proses kombinasi kedua metode. Proses kombinasi ini menghasilkan pengurangan jumlah koloni bakteri paling cepat dan juga menurunkan konsentrasi bakteri ke jumlah koloni paling kecil dengan persentase pengurangan konsentrasi sebesar 99,99 dalam waktu 15 menit. Selain itu, desinfeksi dengan menggunakan ozon saja dengan konsentrasi 231 mg/jam menghasilkan persentase desinfeksi sebesar 99,04 dan kavitasi ultrasonik dengan intensitas 100 menghasilkan persentase desinfeksi sebesar 68 pada menit ke 15.

Combination of ozone and ultrasonic cavitation can be used as an alternative process for disinfection of Escherichia coli where the residual of this process is considered to be more safety than the previous one e.g. chlorination. Ozone can attack membrane cell of bacteria and ultrasonic cavitation has an advantage in generation of OH radicals which make an enzyme denaturation on bacteria. This research divided by three kinds of disinfection method to find the best applicable one, which are disinfection using ozone only, ultrasonic cavitation only and combination of ozone and ultrasonic cavitation. The best condition for E.coli disinfection resulted by this research is when a combination of 231 mg L of ozone and 100 wave intensity is used. This condition gave a result of 99,99 percentage of E.coli disinfection in 15 minutes. Other condition where 231 mg L of ozone is used, resulting 99,04 of disinfection and 100 wave intensity gives 68 of disinfection for 15 minutes."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67262
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>