Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 13447 dokumen yang sesuai dengan query
cover
Sukamta
"Slugging as a water hammer initiator is a fascinating topic because it has a strategic impact on equipment safety in industrial systems, i.e. pressurized water reactors (PWR), heat exchangers, etc. The present research’s objective was to investigate slugging as initiating the water hammer phenomenon through indirect contact steam condensing in a horizontal pipe heat exchanger. The experiment apparatus used in the present experimental study consisted of an inner annulus pipe made of copper (din = 17.2 mm, do = 19 mm) with a length of 1.8 m and an outer annulus pipe of galvanized iron (din = 108.3 mm, do = 114. 3 mm) with a length of 1.6 m. The tested liquid was water. The experiments were conducted at a static pressure of Ps = 108.825 kPa and the temperature of T = 119.7°C. The obtained experimental data of temperature and differential pressure fluctuations were analyzed using statistical analysis. The results were as follows: 1) the flow pattern area of non-slugging (stratified and wavy flow), transition (wavy-slug flow), and slugging (slug and large-slug) were determined, with the transition flow pattern of slug and large-slug defined as initiating water hammer; 2) transition area ranges for the wavy-slug flow pattern are from ?co=1´10-1 kg/s to ?co=6´10-1 kg/s for ?st=6´10-3 kg/s to ?st=7.5´10-3 kg/s, and ?co< 3´10-1 kg/s for ?st=8´10-3 kg/s to ?st=9´10-3 kg/s. These obtained data are very important in order to develop a database for the input of an early warning system design in a safe, two-phase flow installation piping system during steam condensation."
Depok: Faculty of Engineering, Universitas Indonesia, 2015
UI-IJTECH 6:6 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
Antoinnetee Benefita Kusumoningtyas Nugroho
"Salah satu sumber gas alam Indonesia yang terletak di area Natuna Barat memiliki potensi besar untuk memenuhi peningkatan kebutuhan energi. Flow assurance diperlukan untuk menjamin gas alam dapat terus mengalir pada sistem transportasi perpipaan gas alam dalam berbagai kondisi. Hal yang mampu menghambat mengalirnya pasokan gas alam adalah terbentuknya slugging karena penurunan laju alir gas alam serta beberapa faktor lainnya. Studi ini bertujuan untuk memperoleh profil aliran multifasa yang terbentuk di sepanjang pipa transportasi gas alam jika laju alir gas alam mengalami penurunan, mendapatkan pengaruh profil aliran multifasa terhadap terjadinya slugging di dalam sistem perpipaan gas alam, dan memperoleh metode penanganan cairan yang dilakukan di fasilitas penerima. Studi dianalisis menggunakan simulator aliran multifasa minyak dan gas. Simulasi dilakukan pada 3 skenario kondisi sumur, yaitu initial life, mid life, dan late life yang berturut-turut memiliki laju alir gas sebesar 57, 31, dan 5 MMSCFD. Berdasarkan hasil simulasi diperoleh bahwa semakin rendah laju alir gas alam, maka kemungkinan terjadi slugging akan meningkat. Pada studi ini, slugging terjadi pada kondisi late life. Penanganan cairan yang diajukan oleh penulis untuk memitigasi slugging adalah dengan penambahan control valve yang diletakkan pada aliran masukan separator dan memiliki bukaan 60%.

Indonesia's natural gas sources located in the West Natuna area has great potential to meet increasing energy needs. Flow assurance is needed to ensure that natural gas can continue to flow in the natural gas pipeline transportation system under various conditions. One of the things that can hinder the supply of natural gas is the formation of slugging due to a decrease in the flow rate of natural gas and several other factors. This study aims to simulate the multiphase flow that forms along the natural gas transportation pipeline if the flow rate of natural gas decreases, to obtain the effect of the multiphase flow profile on the occurrence of slugging in the natural gas piping system, and to obtain the method of handling liquids carried out at the receiving facility. The study was analyzed using a multiphase oil and gas flow simulator. Simulations were carried out on 3 scenarios of well conditions, namely initial life, mid life, and late life which had gas flow rates of 57, 31, and 5 MMSCFD, respectively. Based on the simulation results, it is found that the lower the natural gas flow rate, the higher the probability of slugging. In this study, slugging occurs in late life conditions. The liquid handling and process improvement proposed by the author to mitigate slugging is by adding a control valve which is placed at the inlet flow of the separator and has an opening of 60%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Christian Emanuel Kefi
"Sistem ACWH memiliki 2 kondensor yang berfungsi untuk memanaskan air dan membuang panas ke lingkungan yang masing-masing memiliki katup in/out pada pipa refrigerant. Dalam sistem ACWH seluruh refrigerant akan dialirkan ke DPHE untuk didinginkan, sehingga bukaan katup DPHE 100% terbuka, sementara aliran refrigerant ke air condenser tertutup. Media pendingin pada DPHE bersumber dari tangki penyimpanan yang di insulasi, jika air tidak digunakan untuk mandi berarti air akan bersirkulasi secara terus menerus dan terus mengalami peningkatan temperatur karena menyerap panas dari refrigerant sehingga panas tersimpan dalam tangki. Temperatur media pendingin terus meningkat menyebabkan pertukaran panas pada sistem tidak maksimal sehingga terjadi penurunan efisiensi kompresor serta peningkatan tekanan dan temperatur discharge. Untuk mengatasi peningkatan tekanan dan temperatur pada kompresor, panas pada sistem harus dilepaskan ke lingkungan sehingga refrigerant harus dialirkan ke air condenser untuk melepaskan panas ke lingkungan. Refrigerant tidak sepenuhnya dialirkan ke air condenser karena panas tetap dibutuhkan ke DPHE untuk memanaskan air, sehingga katup pada kedua kondensor tetap dibuka dengan perbandingan tertentu sesuai dengan kondisi. Katup pada DPHE akan tertutup ketika air panas sudah mencapai temperatur yang diminta. Pada saat ini katup masih dikontrol secara manual sehingga akan tidak efektif ketika digunakan. Untuk mengatasi kendala tersebut katup ini akan dikontrol secara otomatis dengan input command berdasarkan analisis karakter perpindahan panas pada beberapa bukaan katup berbeda pada masing-masing kondensor. Hasil percobaan yang didapatkan hasil tercepat untuk pemanasan air adalah dengan membuka katup ke DPHE 100% dan menutup katup ke kondensor air cooled dengan waktu pemanasan air 31 menit, tetapi terjadi over pressure dan over heat pada discharge kompresor yang mencapai tekanan >25 bar. Sementara pada bukaan 50% DPHE dan 50% air condenser, waktu pemanasan air dari 28°C ke 55°C mencapai 56 menit. Pada mode 3 & 4 dilakukan pengaturan katup ketika temperatur discharge kompresor mencapai 60°C, terlihat penurunan tekanan secara signifikan dalam beberapa saat. Variasi terbaik dari 4 percobaan diatas adalah diawali dengan 100% DPHE dan 75% DPHE, 25% kondensor saat temperature discharge kompresor mencapai 60°C. Hal ini dikarenakan memiliki laju perpindahan panas yang baik dan tekanan discharge terkendali karena Sebagian tekanan dialirkan ke kondensor. Jika tekanan melebihi 16 bar maka bukaan katup DPHE dikurangi dan membuka katup air condenser.

The ACWH system has 2 condensers which serves to heat water and dissipate heat to the environment, both has an in/out valve on the refrigerant pipe. In the ACWH system, all refrigerant will flow to the DPHE to be cooled, so that the DPHE valve opening is 100% open, and the refrigerant flow to the air condenser is closed. The cooling medium in DPHE comes from an insulated storage tank, if the water is not used for bathing it means the water will circulate continuously and the temperature will continue to increase because it absorbs heat from the refrigerant and heat will be stored in the tank. The temperature of the cooling medium continues to increase causing the heat exchange in the system to be not optimal, and causing decrease in compressor efficiency and an increase in discharge pressure and temperature. To overcome the increase in pressure and temperature in the compressor, the heat in the system must be released to the environment so that the refrigerant must be flowed into the air condenser to release heat to the environment. Refrigerant is not completely flowed into the air condenser because heat is still needed to the DPHE to heat the water, so the valves on both condensers are still opened with a certain ratio according to conditions. The valve on the DPHE will close when the hot water has reached the required temperature. At this time the valve is still controlled manually, so it will be ineffective when used. To overcome these obstacles, this valve will be controlled automatically with an input command based on the analysis of the heat transfer character at several different valve openings in each condenser. The experimental results obtained the fastest results for heating water are to open the valve to 100% DPHE and close the valve to the water cooled condenser with a water heating time of 31 minutes, but there is over pressure and over heat on the compressor discharge which reaches a pressure of >25 bar. Meanwhile, at 50% DPHE and 50% air condenser openings, the water heating time from 28°C to 55°C reaches 56 minutes. In mode 3 & 4, the valve is adjusted when the compressor discharge temperature reaches 60°C, a significant drop in pressure is seen in a few moments. The best variation from the 4 experiments above is starting with 100% DPHE and 75% DPHE, 25% condenser when the compressor discharge temperature reaches 60°C. This is because it has a good heat transfer rate and the discharge pressure is controlled because some of the pressure is supplied to the condenser. If the pressure exceeds 16 bar then the DPHE valve opening is reduced and the air condenser valve opens."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Miftah Rafi
"Kebocoran adalah salah satu masalah besar yang sering terjadi dalam sebuah sistem perpipaan, baik itu untuk membawa cairan multi-fasa atau fasa-tunggal. Salah satu industri minyak dan gas Indonesia mengalami masalah kebocoran pada ketiga sistem pipa waterflood di salah satu lokasi lepas pantai mereka. Untuk mengatasi masalah ini, mereka berencana untuk menjalankan salah satu proyek mereka, yaitu PRRP (Pipeline Repair and Replacement Project). Proyek ini perlu beberapa studi pendahuluan untuk dilaksanakan, dan salah satu studinya adalah mengenai fenomena water hammer. Penelitian ini mengusulkan studi tentang pengaruh fenomena water hammer pada dua jenis pipa, rigid dan flexible. Secara total, empat variasi pipa akan digunakan, API 5L X52 untuk pipa rigid, dan tiga variasi RTP untuk pipa flexible. Metode untuk penelitian ini menggunakan perangkat lunak aliran multi-fase dinamis, OLGA v.2017.2.0, untuk mendapatkan profil tekanan transien fenomena water hammer. Variabel utama dari penelitian ini adalah modulus elastisitas Young dan parameter operasi. Modulus elastisitas Young divariasikan berdasarkan komposisi material setiap pipa. Parameter operasi yang divariasikan adalah laju aliran volumetrik dengan masing-masing nilai 10.000, 15.000, dan 20.000 STB/d, dan waktu penutupan katup dengan masing-masing nilai 1, 3, dan 9 detik. Hasil menunjukkan perubahan tekanan yang tinggi dan durasi transien yang lama untuk pipa API 5L X52. Untuk RTP, perubahan tekanan dan durasi transien tergantung pada rasio reinforcement-nya. Untuk RTP dengan rasio reinforcement 11,84%, menghasilkan perubahan tekanan yang lebih tinggi daripada API 5L X52 karena dimensi yang berbeda, tetapi tetap memiliki durasi transien yang lebih cepat. Untuk dua variasi rasio lainnya, 2,96% dan 5,92%, secara signifikan perubaha tekanan yang terjadi lebih rendah dan durasi transien juga yang lebih cepat. Semua variasi parameter operasi menunjukkan pengaruh yang signifikan pada semua jenis pipa dan sesuai dengan teori dasar. Untuk kebutuhan keamanan, semua jenis pipa masih aman digunakan karena tidak ada perubahan tekanan yang melebihi set point PSH.

Leaking is one of the major problems that isoften to occur in pipeline systems, whether it is for carrying a multi-phase or a single-phase liquid. In 2015 and 2017, one of Indonesias major oil and gas industry has suffered a leaking problem on all three waterflood pipeline systems in one of their offshore sites. To overcome this problem, they are planning to execute one of their projects, PRRP (Pipeline Repair and Replacement Project). This certain project needs several preliminary studies to be executed, and one of the studies is about the water hammer phenomenon. This research proposes a study on the effect of water hammer phenomenonon two kinds of pipe, rigid and flexible. In total, four pipes are used, API 5L X52 for rigid pipe, and three varietiesof RTP for the flexible pipe. The methodology uses a dynamic multi-phase flow software, OLGA v.2017.2.0, to obtain the transient pressure profile of the water hammer phenomenon. Main variables of this research are the Youngs modulus of elasticity and operating parameters. The Youngs modulus is variated based on the material composition of each pipe. The operating parameters variedare the volumetric flow rate with each value of 10.000, 15.000, and 20.000 STB/dan the valve closure time with each value of1, 3, and 9 seconds. The results show high pressure change and long transient duration for API 5L X52 pipe. For RTP, pressure change and transient duration depend on the reinforcement ratio. For RTP with 11,84% reinforcement ratio, higher pressure change occurs than API 5L X52 because of the dimension differences, but still faster transient duration. For the other two ratio number, 2,96% and 5,92%, significantly lower pressure changes and faster transient duration occur. All the results from operating parameters variations show a significant effect on all pipes and correspondto the basic theory. For safety requirements, all kinds of pipe are still safe to use because theres no pressure change that exceeds the PSH set point."
Depok: Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Tte h water hemma pro,one the most -important question of unsteady flow in pipelines....."
Artikel Jurnal  Universitas Indonesia Library
cover
Faiz Gading Rahmadana
"Global warming merupakan kejadian dimana suhu rata-rata permukaan bumi mengalami peningkatan akibat adanya gas rumah kaca. AC menjadi salah satu sistem yang menggunakan gas rumah kaca tersebut. Panas yang dimiliki refrijeran dipindahkan ke lingkungan oleh kondensor. Panas tersebut dapat dimanfaatkan untuk memanaskan air menggunakan alat penukar kalor pipa ganda atau double pipe heat exchanger (DPHE).
Refrijeran yang keluar dari kompresor dengan tekanan dan temperatur yang tinggi akan dialirkan menuju DPHE dimana pada saat yang bersamaan air akan mengalir dengan bantuan pompa dari tangki penyimpanan air menuju DPHE. Pada DPHE, aliran yang terbentuk yaitu counter-current dimana perpindahan kalor terjadi secara konveksi dan konduksi, sehingga refrijeran yang keluar dari DPHE akan memiliki suhu lebih rendah dan air yang mengalir keluar dari DPHE akan memiliki suhu yang lebih tinggi. Kemudian, refrijeran akan melanjutkan siklus refrijerasi dan bergerak menuju katup ekspansi, sedangkan air akan masuk ke dalam tangki penyimpanan air yang diinsulasi sehingga temperatur air panas dapat dijaga dan siap digunakan untuk kebutuhan rumah tangga/domestik.
Tujuan dari penelitian ini adalah merancang DPHE dan melakukan pengujian untuk mengetahui karakteristik DPHE dalam memanaskan air. DPHE menggunakan pipa tembaga sebagai pipa dalam 3/8 inch dan pipa galvanis 1 inch sebagai pipa luar dengan panjang total area pertukaran panas sebesar 15,2 m. Dengan menggunakan DPHE dan tangki penyimpanan air panas 50 L dimana airnya terus bersikulasi dengan bantuan booster pump dengan debit 5 L/menit, didapatkan air panas yang keluar dari DPHE dengan temperatur maksimal sebesar 71,3 oC selama 49 menit. Sedangkan untuk mencapai temperatur sesuai standar SNI 03-7065-2005 yaitu 45oC, dari enam pengujian dibutuhkan waktu rata-rata selama 36 menit.

Global warming happens when the average temperature of the earth increases caused by greenhouse gases. AC is one of the systems that using greenhouses gas. The heat from the refrigerant is absorbed by the air in the condenser. We can use the heat to heating water with the help of DPHE.
The refrigerant that comes out of the compressor with high pressure and temperature will flow to the double pipe heat exchanger where at the same time the water will flow with the help of a booster pump from the water storage tank to the double pipe heat exchanger. In the double pipe heat exchanger, the flow that is formed is a counter-current where heat transfer occurs by convection and conduction so that the refrigerant that comes out of the double pipe heat exchanger will have a lower temperature and the water that flows out of the double pipe heat exchanger will have a higher temperature. Then, the refrigerant will continue the refrigeration cycle and move towards the expansion valve, while the water will enter the insulated water storage tank so that the hot water temperature can be maintained and is ready to be used for domestic needs.
The purposes of this research are to design DPHE and conduct a test to determine the characteristics of DPHE in heating water. DPHE uses the copper pipe 3/8 inch as an inner pipe and galvanized pipe 1 inch as an outer pipe with a total length of heat exchanger area of 15,2 m. Using DPHE and hot water storage tank 50 L which the water circulates inside the system with the help of a booster pump with a flow rate of 5 L/min, the hot water from DPHE can reach a maximum temperature of 71,3 oC within 49 minutes. Meanwhile, to reach the standard temperature based on SNI 03- 7065-2005 which is 45 oC, it takes an average time of 36 minutes from six tests.
"
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bimasena Duanda Harimawan
"Mengurangi dan menghemat konsumsi energi di era modern merupakan hal penting untuk dilakukan. Tidak hanya di masa sekarang, penggunaan konsumsi energi dalam waktu dekat untuk hidup berkelanjutan dengan lingkungan yang ramah lingkungan juga sangat penting. Pemanas air membutuhkan energi listrik yang tinggi dibandingkan peralatan rumah tangga lainnya. Saat ini sudah banyak pemanas air yang menggunakan energi terbarukan sebagai sumber utama, namun masih banyak pemanas air pada sistem perumahan yang tidak ramah lingkungan karena tidak menghemat penggunaan energi. Begitu juga dengan penggunaan AC di perumahan dan juga di perkantoran. Tujuan dari penelitian ini adalah untuk memanfaatkan panas buang dari udara kondenser AC split sebagai pemanas awal dalam heater air atau Air Conditioner Water Heater (ACWH) dengan menggunakan heat pipe. Sehingga diharapkan konsumsi energi untuk pengoperasian water heater menjadi lebih rendah. Metode yang dilakukan dalam penelitian ini adalah menambahkan perangkat heat pipe heat exchanger di sisi keluar udara outdoor kondenser, dimana sisi evaporator heat pipe diletakkan di sisi udara panas buang kondenser, sedangkan sisi kondenser heat pipe diletakkan diletakkan di air dalam tangki. Perangkat heat pipe terdiri dari 17 heat pipe, satu baris, dimana sisi evaporator dilengkapi sirip-sirip, dan sisi kondenser tanpa menggunakan heat pipe. Hasil penelitian menunjukkan bahwa pengguaan heat pipe mampu menghasilkan suhu air meningkat 3 oC pada siang hari, sedangkan pada malam hari suhu air menurun pada kondisi ruangan tanpa beban kalor.

Reducing and saving energy consumption in the modern era is an important thing to do. Not only in the present, the use of energy consumption in the future for sustainable living in an environmentally friendly environment is also critical. Water heaters require higher electrical energy than other household appliances. Currently, many water heaters use renewable energy as the primary source. However, there are still many water heaters in residential systems that are not environmentally friendly because they do not save energy use, likewise with the usage of air conditioning in housing and offices. The purpose of this study was to utilize the exhaust heat from split AC condenser air as a preheater in a water heater or Air Conditioner Water Heater (ACWH) using a heat pipe. So, it is expected that energy consumption for water heater operation will be lower. The method used in this study is to add a heat pipe heat exchanger device to the outside of the condenser outdoor air, where the evaporator side of the heat pipe is placed on the hot air exhaust side of the condenser. In contrast, the condenser side of the heat pipe is placed in the water in the tank. The heat pipe device consists of 17 heat pipes, one row, where the evaporator side is equipped with fins, and the condenser side without using a heat pipe. The results showed that the use of heat pipes was able to produce an increase in water temperature of 3 ° C during the day, while at night the water temperature decreased in room conditions without the cooling load."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rizky Esa Respati
"ABSTRAK
Kebutuhan air bersih di Dunia semakin meningkat, sementara jumlahnya semakin berkurang dikarenakan sumber air yang semakin menurun. Untuk mengatasi hal tersebut, akan digunakan teknologi desalinasi berbasis teknologi wickless-heat pipe sebagai salah satu solusi untuk menghasilkan air bersih. Tujuan penelitian ini adalah mendesain alat desalinasi berbasis teknologi wickless-heat pipe yang efektif untuk diterapkan dalam desalinasi dengan memanfaatkan tenaga matahari. Tujuan penelitian adalah mengetahui efektivitas alat tersebut sehingga untuk menghasilkan air tawar, dan mengetahui fenomena yang terjadi dalam proses desalinasi berbasis teknologi wickless-heat pipe. Penelitian dilakukan secara eksperimental dengan menguji kemampuan alat desalinasi bertingkat berbasis teknologi wickless-heat pipe two phase closed thermosyphon .Plat asbsorber aluminium digunakan untuk memanaskan air laut di bak pertama dan Wickless-Heat pipe digunakan untuk menyerap energi kalor matahari yang akan digunakan dalam mengevaporasi air laut yang ada di dalam bak setelahnya. Pengujian yang dilakukan dengan memvariasikan flow rate di jalur inlet dan ketinggian air di bak desalinasi bagian atas. Dari penelitian ini diketahui bahwa,hasil maksimum yang dapat dihasilkan sistem desalinasi selama satu hari adalah 310 ml dengan efisiensi harian maksimum sebesar 23 . Pengunaan wickless-heat pipe pada sistem desalinasi mengakibatkan naik nya efisiensi sistem desalinasi hingga 15.

ABSTRACT
World citizens always increasing each second, so fresh water as the major needs for human would rise too. Meanwhile, quantity of fresh water is dwindling because of diminishing water resources. To overcome this, we should use the beneficial solar clean renewable energies, especially for remote areas. In this study, to absorb the solar energy , we used integrated cascading solar desalination utiliizing plate absorber and wickless heat pipe as one solution to produce clean fresh water. The purpose of this study is to design desalination apparatus , which not only effective producing fresh water but also have a good efficiency in absorbing solar energy. The research objective was to determine the effectiveness of the apparatus so as to produce fresh water, and knowing the phenomena that occurs in the desalination process. The apparatus works by seawater flowing from the reservoir to the Plate absorber, which is used to preheat the sea water in the first level basin and then wickless heat pipe is used to absorb solar heat energy to be evaporated water in the second tier basin afterwards. Wickless heat pipes two phase closed thermosyphon used in this experiment has a 60 cm long with 60 filling ratio and 50 aspect ratio. Experiments were performed by varying the flow rate in the inlet of the apparatus and the water height in the first level basin. From this research it is known that the daily maximum yield that can be produced by the desalination system is 310 ml with maximum daily efficiency of 23 . The use of wickless heat pipe on the desalination system resulted in an increase in the efficiency of the desalination system by up to 15. "
2017
S68913
UI - Skripsi Membership  Universitas Indonesia Library
cover
London: Academic Press, 1984
333.91 MOD
Buku Teks SO  Universitas Indonesia Library
cover
Antoinnetee Benefita Kusumoningtyas Nugroho
"Salah satu sumber gas alam Indonesia yang terletak di area Natuna Barat memiliki potensi besar untuk memenuhi peningkatan kebutuhan energi. Flow assurance diperlukan untuk menjamin gas alam dapat terus mengalir pada sistem transportasi perpipaan gas alam dalam berbagai kondisi. Hal yang mampu menghambat mengalirnya pasokan gas alam adalah terbentuknya slugging karena penurunan laju alir gas alam serta beberapa faktor lainnya. Studi ini bertujuan untuk memperoleh profil aliran multifasa yang terbentuk di sepanjang pipa transportasi gas alam jika laju alir gas alam mengalami penurunan, mendapatkan pengaruh profil aliran multifasa terhadap terjadinya slugging di dalam sistem perpipaan gas alam, dan memperoleh metode penanganan cairan yang dilakukan di fasilitas penerima. Studi dianalisis menggunakan simulator aliran multifasa minyak dan gas. Simulasi dilakukan pada 3 skenario kondisi sumur, yaitu initial life, mid life, dan late life yang berturut-turut memiliki laju alir gas sebesar 57, 31, dan 5 MMSCFD. Berdasarkan hasil simulasi diperoleh bahwa semakin rendah laju alir gas alam, maka kemungkinan terjadi slugging akan meningkat. Pada studi ini, slugging terjadi pada kondisi late life. Penanganan cairan yang diajukan oleh penulis untuk memitigasi slugging adalah dengan penambahan control valve yang diletakkan pada aliran masukan separator dan memiliki bukaan 60%
Indonesia's natural gas sources located in the West Natuna area has great potential to meet increasing energy needs. Flow assurance is needed to ensure that natural gas can continue to flow in the natural gas pipeline transportation system under various conditions. One of the things that can hinder the supply of natural gas is the formation of slugging due to a decrease in the flow rate of natural gas and several other factors. This study aims to simulate the multiphase flow that forms along the natural gas transportation pipeline if the flow rate of natural gas decreases, to obtain the effect of the multiphase flow profile on the occurrence of slugging in the natural gas piping system, and to obtain the method of handling liquids carried out at the receiving facility. The study was analyzed using a multiphase oil and gas flow simulator. Simulations were carried out on 3 scenarios of well conditions, namely initial life, mid life, and late life which had gas flow rates of 57, 31, and 5 MMSCFD, respectively. Based on the simulation results, it is found that the lower the natural gas flow rate, the higher the probability of slugging. In this study, slugging occurs in late life conditions. The liquid handling and process improvement proposed by the author to mitigate slugging is by adding a control valve which is placed at the inlet flow of the separator and has an opening of 60%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>