Nizhamul Latif
"Dalam penelitian ini dilakukan study tentang pengaruh ion chlorida terhadap pemanfaat inhibitor nitrit dan betz didalam air pendingin. Dari penelitian tersebut diketahui bahwa :
1. Pemakaian inhibitor nitrit, efektif untuk air baku tanpa NaCl dan yang mengandung NaCl 20,200 & 400 ppm setelah konsentrasi inhibitor masing-masing melebihi 150 ppm, 200 ppm, 300 ppm dan 500 ppm.
2. Pemakaian inhibitor betz, efektif untuk air baku tanpa NaCl dan yang mengandung NaCl 20,200 & 400 ppm setelah konsentrasi inhibitor masing-masing melebihi 100 ppm, 150 ppm, 400 ppm dan 600 ppm.
3. Pada konsentrasi NaCl yang rendah pemakaian inhibitor Betz lebih efektif dibanding inhibitor nitrit.
4. Sedangkan pada konsentrasi NaCl yang tinggi pemakaian inhibitor nitrit lebih efektif dibanding inhibitor betz."
Depok: Universitas Indonesia, 1993
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Angga Panji Satria Pratama
"Chiller merupakan mesin refrigerasi non – direct expansion yang biasa dipakai untuk beban pendinginan yang besar. Media pendinginnya yaitu berupa air atau udara yang mengalir bersirkulasi melewati heat exchanger.
Air-cooled chiller yang memakai kompresor dari Copeland dengan berdaya 3 PK ingin digunakan untuk merancang sebuah kondenser. Dari hasil perhitungan diperoleh kapasitas kondenser sebesar 10,945 kW dengan temperatur masuk kondenser 49-55 ˚C dan temperatur keluar kondenser 47-53 ˚C. Daya fan yang bervariasi harus diberikan dengan diameter hub berbeda – beda. Daya terkecil yaitu 716 Watt untuk tipe A dan 1925 Watt untuk tipe E.

Chiller is a refrigeration machine non-direct expansion that is usually used for large cooling loads. The cooling medium is a water or air flowing through the heat exchanger.
Air-cooled chiller that used compressor from Copeland with power 3 PK wants to use to design a condenser. From the calculation, the condenser capacity of 10,945 kW with incoming condenser temperature 49-55 ˚C and condenser exit temperature 47-53 ˚C. Varying fan power should be given to the hub diameter difference. The smallest power 716 Watt for type A and the largest power 1925 Watt for type E.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47201
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gerry Julian
"Heat exchanger merupakan bagian vital dalam sebuah perangkat elektronik yang dapat menjaga suhu optimum dari alat tersebut. Penelitian tentang microchannel heat exchanger telah sangat berkembang untuk aplikasi kearah pendingin elektronik pada satu dekade terakhir ini. Microchannel heat exchanger memiliki beberapa keunggulan yakni memiliki dimensi yang lebih kecil dan memiliki koefisien perpindahan kalor yang lebih baik daripada alat penukar kalor lainnya. Dalam pengujian ini, peneliti akan mencoba membuktikan performa dari koefisien perpindahan kalor dari microchannel heat exchanger tersebut beserta efek negatifnya. Peneliti akan mencoba menguji pengaruh pressure drop pada saluran microchannel heat exchanger. Kemudian dalam pengujian ini juga digunakan fluida kerja air,nano fluida Al2O3 1%, dan nano fluida SnO2 1% dengan fluida dasar air. Dari hasil pengujian ini didapatkan bahwa perpindahan kalor akan lebih baik jika menggunakan nano fluida sebagai fluida kerja pendingin.

Heat exchanger is a vital part in an electronic devices that can maintain the optimum operation temperature of that devices. Research on microchannel heat exchanger application has been highly developed on electronics cooling towards the last decade. Microchannel heat exchanger has several advantages which have smaller dimensions and heat transfer coefficient better than the other heat exchanger. The experiment also want to measure the pressure drop in microchannel. It used water, nanofluids Al2O3 1%,and nanofluids SnO2 1% as working fluids in cold side microchannel heat exchanger. Result from this research indicate that heat transfer would be better if we use nanofluids as cooling working fluids."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42955
UI - Skripsi Open  Universitas Indonesia Library
cover
Ary Maulana
"Kinerja perpindahan kalor pada alat penukar kalor dapat ditingkatkan dengan mengurangi ukuran diameter hidrolik atau dengan menggunakan fluida kerja yang memiliki konduktivitas termal lebih baik dibandingkan dengan fluida kerja konvensional. Salah satu contoh penggunaan diameter hidrolik yang kecil adalah microchannel heat exchanger (MCHE). Pada penelitian ini, perancangan alat dan pengujian kinerja perpindahan kalor pada MCHE berkonfigurasi counter-flow dengan menggunakan fluida kerja air dan nano fluida Al2O3-air dengan konsentrasi 1%, 3%, dan 5% sebagai fluida pendingin telah dilakukan. Dalam pengujian, temperatur masuk fluida pada sisi panas dan sisi dingin MCHE diatur tetap pada temperatur 50°C dan 25°C, sedangkan debit aliran pada saluran masuk divariasikan dari 100 ml/menit hingga 300 ml/menit.
Hasil pengujian menunjukkan bahwa peningkatan konsentrasi partikel nano pada fluida dasar dapat meningkatkan kinerja perpindahan kalor fluida dasar tersebut. Pada konsentrasi partikel nano tertinggi yang digunakan dalam pengujian, nano fluida Al2O3-air konsentrasi 5% dapat menyerap panas sebesar 9% lebih baik dibandingkan air biasa dan dapat meningkatkan koefisien perpindahan kalor keseluruhan MCHE sebesar 13% lebih besar dibandingkan dengan air.

The heat transfer performance in heat exchanger can be enhanced by decreasing its hydraulic diameter or using working fluid that has better thermal conductivity than the conventional one. One of the examples of small hydraulic diameter application is microchannel heat exchanger (MCHE). Designing the MCHE and doing experimental investigation of the heat transfer performance on counter-flow MCHE by using water and Al2O3-water nanofluid with nanoparticle concentration 1%, 3%, and 5% as coolant fluid has been done in this experiment. Inlet fluid temperatures in hot and cold side are set at 50°C and 25°C, meanwhile the inlet flow rate is set from 100 to 300 ml/minute.
The experimental results show that the increase of nanoparticle concentration in the base fluid can enhance its heat transfer performance. In highest concentration of nanoparticle used in this experiment, Al2O3-water 5% nanofluid can absorb heat 9% better than conventional water do and can enhance the overall heat transfer coefficient of MCHE 13% higher than water.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43033
UI - Skripsi Open  Universitas Indonesia Library
cover
cover
Fakultas Teknik Universitas Indonesia, 2004
S37515
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 2003
TA3280
UI - Tugas Akhir  Universitas Indonesia Library
cover
Irawan Sentosa
"ABSTRAK
Termoakustik merupakan metode dimana suara dapat menghasilkan perbedaan temperatur dan sebaliknya, perbedaan temperatur dapat menghasilkan osilasi suara. Terdapat tiga bagian utama pada temoakustik gelombang berdiri yaitu stack, penukar kalor, dan tabung resonator. untuk mendapatkan osilasi suara yang optimal dipengaruhi oleh beberapa aspek seperti dimensi dan posisi stack, bentuk dan panjang dari tabung resonator serta fluida yang digunakan. Penelitian ini bertujuan untuk mengamati pengaruh dari panjang dan posisi stack terhadap osilasi yang dihasilkan. Pengujian dilakukan dengan menggunakan resonator berupa tabung pyrex 200 mm dan stack berbahan steel wool dengan panjang 30 mm, 35 mm, 40 mm dan 45mm. Posisi stack ditempatkan bervariasi yaitu pada 0 ,10 20, 30, 40, 50, 60, 70, 80, 90 dan 100 mm dari ujung tertutup resonator.Pada pengujian diperoleh bahwa pada posisi 0-10mm dari ujung tertutup. Suara dan daya akustik maksimal diperoleh saat menggunakan stack dengan panjang 40 mm dengan posisi 50mm dari ujung tertutup yaitu 1.15 Watt.

ABSTRACT
Termoacoustic is a method in which voice can generate a temperature difference and vice versa, the temperature difference can produce sound oscillations. There are three main parts of thermoacoustic standing wave, the stack, heat exchangers, and tube resonator. Optimal sound oscillation is influenced by several aspects such as the dimensions and position of the stack, shape and length of tube resonator and fluid used. This study aimed to observe the effect of position and length of stack to acoustic power generated by thermoacoustic-standing wave. Experiment did using pyrex tube 200 mm in length as a resonator and using steel wool as a stack. Variations of stack lenght are 30 mm, 35 mm, 40 mm and 45 mm. Stack was placed at 0 ,10 20, 30, 40, 50, 60, 70, 80, 90 and 100 mm from closed end aof resonator. The experiment show that sound could not generated with stack position at 0-10 mm from closed end. Maximum sound and acoustic power produced when using stack 40 mm in length and position 50 mm from closed end with 1.15 watt"
Fakultas Teknik Universitas Indonesia, 2012
T32743
UI - Tesis Membership  Universitas Indonesia Library
cover
Andi Bakhtiar
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36328
UI - Skripsi Membership  Universitas Indonesia Library
cover
Indra Setiawan
"Alat penukar kalor (heat exchanger) mempunyai peran yang sangat penting dalam dunia industri, khususnya pada industri minyak dan gas bumi. Alat penukar panas ini berfungsi untuk menaikkan suhu fluida yang lebih rendah dan atau mendinginkan suhu fluida yang lebih tinggi. Di Santan Terminal, salah satu gathering station milik Chevron Indonesia Company, alat penukar kalor unit HE-7 digunakan untuk memberikan panas awal pada hydrocarbon C4+ dalam proses kondensat depropanizer, dengan mengambil panas dari hot oil system menggunakan Terminol 55 sebelum dilakukan pemprosesan lebih lanjut. Untuk mempertahankan kinerja alat penukar kalor unit HE-7, dilakukan penelitian dengan memodifikasi sistem kerja feeder pump yang ada pada proses proses kondensat depropanizer tersebut, sehingga tingkat kinerja alat penukar panas dapat dipertahankan pada nilai efesiensi yang diharapkan.

Heat exchanger has a very important role in the industrial world, especially in oil and gas industry. Heat exchanger serves to raise the fluid temperature which is lower and / or cool the fluid temperature wich is higher. At Santan Terminal, one of the gathering station owned by Chevron Indonesia Company, the unit heat exchangers HE-7 is used to provide initial heat to the hydrocarbon C4+ in the process condensate depropanizer, by taking heat from the hot oil system using Terminol 55 prior to further processing. To maintain the performance of the unit heat exchanger HE-7, research done by modifying the feeder system of pump work in the process of the condensate depropanizer, so the heat exchanger performance can be mantain at expected effeciency number. "
Depok: Fakultas Teknik Universitas Indonesia, 2011
S369
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>