Pontoh, Putri Amalia
"ABSTRAK
Potensi induksi radiasi sekunder tidak hanya bergantung pada jumlah dosis penyerapan yang diberikan, tetapi juga pada karakteristik pasien. Selama perlakuan terapi menggunakan Gamma Knife Radiosurgery (GKRS), tubuh pasien menerima iradiasi akumulasi dosis hamburan dan kebocoran. Oleh karena itu, perlu untuk mengetahui dosis radiasi organ kritis pasien yang diterima selama perawatan Gamma Knife Radiosurgery dan membandingkan dengan batasan dosis masing-masing organ. Pengukuran dilakukan dengan menggunakan dosimeter film GafChromic XR-QA2 dan thermoluminescent dosimeter (TLD) yang diletakkan pada permukaan organ kritis fantom. Pemasangan head frame di fantom antropomorfik (Alderson Rando Phantom, Laboratorium Penelitian Alderson, Inc., Stamford, Connecticut) dan scalp measurement digunakan untuk mengukur geometri kepala fantom. Magnetic Resonance Imaging (MRI) digunakan untuk memperoleh citra fantom antropomorfik dan kemudian dipindahkan ke Leksell Gamma Planning (LGP) untuk menentukan perencanaan posisi target, distribusi dosis dan dosis preskripsi maksimum pada target 36 Gy. Unit LGK Perfexion (Elekta AB, Stockholm, Swedia) digunakan untuk menyinari fantom dengan target diposisikan di tengah, dan volume target divariasi dari 5 cc, 10 cc, 15, dan 20 cc serta ukuran kolimator dari 4 mm, 8 mm, dan 16 mm. Dosimeter diletakkan di permukaan lensa, tiroid, payudara, fundus uterus, ovarium, dan testis. Kemudian dosimeter dianalisa untuk memperoleh dosis pada organ kritis. Hasil pengukuran menunjukkan bahwa dosis yang terlihat pada lensa, tiroid, dan payudara dipengaruhi oleh jarak organ dari target, volume target, dan ukuran kolimator. Diperoleh bahwa dosis radiasi pada organ kritis berkontribusi kurang dari 3%, relatif terhadap dosis target maksimum. Dosis radiasi pada organ kritis yang diambil menggunakan film GafChromic XR-QA2 lebih tinggi dibandingkan TLD dengan diskrepansi mencapai 50%. Jika dibandingkan dengan referensi, pengukuran dosis XR-QA2 tidak jauh berbeda sehingga diketahui bahwa film XR-QA2 dapat digunakan untuk mengukur radiasi hambur. Namun, perhatian khusus dan optimisasi harus dilakukan untuk perencanaan perlakuan dengan mempertimbangkan ukuran kolimator yang digunakan dan meminimalkan waktu perlakuan.

ABSTRACT
The potential for secondary radiation induction depends not only on the amount of absorption dose received, but also on patient characteristics, such as age (in general, younger patients will be more vulnerable). During treatment using Gamma Knife Radiosurgery (GKRS), patient's body receives an dose accumulation from scattering and leakage. Therefore, it is necessary to know the dose of patient's organs at risk (OAR) received during Gamma Knife Radiosurgery treatment and compare it with the dose limit of each organs. Measurements obtained using a GafChromic XR-QA2 dosimeter and thermoluminescent dosimeter (TLD) placed on the surface of phantom critical organs. Installation of head frame in anthropomorphic phantom (Alderson Rando Phantom, Alderson Research Laboratory, Inc., Stamford, Connecticut) and scalp measurement used to measure phantom head geometry. Magnetic Resonance Imaging (MRI) used to obtain anthropomorphic phantom image and then transferred to the Leksell Gamma Planning (LGP) to determine the planning treatment planning such as target position, dose distribution and target maximum prescription dose at 36 Gy. The LGK Perfexion unit (Elekta AB, Stockholm, Sweden) used to illuminate the phantom with the target positioned in the middle, and the target volume varies from 5 cc, 10 cc, 15 and 20 cc and collimator sizes from 4 mm, 8 mm and 16 mm. The dosimeters placed on the surface of the lens, thyroid, breast, uterine fundus, ovaries and testes. Then the dosimeters analyzed to obtain the dose in OAR. The measurement results shows that the dose at lens, thyroid, and breast depend on the distance from the target, target volume, and collimator size. The radiation dose in OAR contributed less than 3%, relative to the maximum target dose. The radiation dose in critical organs taken using GafChromic XR-QA2 film is higher than TLD with a 50% discrepancy. When compared with the reference, the measurement of XR-QA2 dose is not much different so it is known that XR-QA2 film can be used to measure scattering radiation. However, special attention and optimization must be done for treatment planning by considering the size of the collimator used and minimizing the treatment time."
2020
T55381
UI - Tesis Membership  Universitas Indonesia Library
cover
I Nyoman Pranditayana
"ABSTRAK
Leksell gamma knife (LGK) adalah salah satu modalitas terapi radiasi yang bersumber dari radioaktif Co-60. Teknik lapangan kecil dengan pemberian dosis radiasi tinggi kepada pasien dalam satu sesi harus dihitung secara akurat dan diverifikasi dengan cermat. Penelitian ini menggambarkan prosedur untuk memverifikasi keakuratan distribusi dosis pada Leksell Gamma Plan (LGP) menggunakan fantom RANDO dan film gafchromic EBT3. Pertama, dilakukan verifikasi berkas profil pada fantom standar LGK dan RANDO menggunakan ukuran kolimator 4 mm, 8 mm dan 16 mm untuk memperoleh nilai full width half maximum (FWHM), penumbra dan beam-symmetry, nilai FWHM yang diperoleh dibandingkan dengan nilai pada LGP. Selanjutnya verifikasi nilai dosis serap pada RANDO dengan vasiasi ukuran kolimator, jumlah shoot, volume dan lokasi tumor, diverifikasi mengggunakan film EBT3. Perhitungan distribusi dosis dilakukan menggunakan perangkat lunak ImageJ dan program MATLAB. Penelitian ini menunjukkan perbedaan nilai FWHM dan beam-symmetry terkecil antara LGP ​​dan fantom standar LGK terjadi pada ukuran kolimator 16 mm sebesar 0.42 mm dan 1.58% sedangkan perbedaan pada fantom RANDO adalah 0.45 mm dan 1.64%. Verifikasi dosis maksimum menunjukkan pada variasi jumlah shoot, kolimator 16 mm memiliki nilai deviasi yang paling stabil. Kesimpulannya, kolimator ukuran 16 mm memiliki akurasi nilai dosis, FWHM dan beam-symmetry sangat baik. Namun, pada volume tumor yang lebih kecil, kolimator 16 mm dengan single shoot memberikan nilai deviasi yang lebih tinggi.

ABSTRACT
Leksell gamma knife (LGK) is an advanced modality of radiation therapy sourced Co-60 radioactive for treating patient with intracranial lesion. Small field techniques with highly integrated radiation delivering to patients in single session must be calculated accurately and verified carefully. This study illustrates a procedure to verify the accuracy of dose distribution associated with Leksell Gamma Plan (LGP) using RANDO phantom and gafchromic EBT3 film dosimetry. First, we assessed the profile dose on LGK standard phantom with collimators size 4,8 and 16 mm and compared the results with the profile dose based on RANDO to obtained Full Width Half Maximum (FWHM), penumbra and beam-symmetry. Absorbed-dose distributions on RANDO with various combinations of lesion volume, collimator size, location and number of shots assessed by EBT3 film using LGK Perfexion. Scanned images of the measured films were processed following standard EBT3 film-handling procedures. Dose value calculation were performed using ImageJ software and MATLAB in-house software. The study shows samallest difference of FWHM and beam symmetry occurs at collimator size 16 mm, whereas discrepancy in standard phantom between LGP and measurement is 1.83 % and 1.58 % respectively and the discrepancy in RANDO phantom is 2.15 %, and 1.64 % respectively. Verification of max dose shows, colimator size 16 mm has the most stable deviation value in variation of number of shoots. In conclusion, collimator size 16 mm have a highest accuracy of dose value, FWHM and beam-symmetry value. However, on smaller lesion volume, collimator 16 mm with single shot give higher deviation dose value."
2020
T55317
UI - Tesis Membership  Universitas Indonesia Library
cover
Aninda Fitriandini
"Telah dilakukan penelitian pengukuran dosis titik (point dose) pada daerah target (paru-paru), jantung, dan tulang belakang menggunakan empat dosimeter (PTW N30013, Exradin A16, TLD, dan film Gafchromic EBT2). Tujuan utama dari penelitian ini adalah membandingkan keempat sistem dosimeter tersebut dalam hal akurasi, presisi, rentang pengukuran, serta resolusi spasial dan ukuran fisik. Pengukuran dosis dilakukan hanya pada satu kali fraksi penyinaran. Hasil pengukuran menunjukkan bahwa TLD memiliki akurasi dan presisi yang paling rendah. Adapun efek volume averaging pada bilik ionisasi menyebabkan nilai diskrepansi mencapai -13.30% pada daerah target. Sedangkan film EBT2, dengan nilai diskrepansi <1% pada 3D-CRT dan IMRT, dinyatakan sebagai dosimeter alternatif yang sesuai untuk digunakan pada verifikasi dosis titik.
This research was conducted by measuring point dose in the target area (lungs), heart, and spine using four dosimeters (PTW N30013, Exradin A16, TLD, and the Gafchromic EBT2 film). The main objective of this study was to compare the dosimetry of those different systems. Dose measurements performed only in single fraction of irradiation. The measurement results shown that TLD has the least accuracy and precision. As the effect of the volume averaging, ionization chamber reaches the discrepancy value up to -13.30% in the target area. EBT2 film has discrepancy value of <1% in the 3D-CRT and IMRT techniques. This dosimeter is proposed to be an appropriate alternative dosimeter to be used at dose point verification."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
S59860
UI - Skripsi Membership  Universitas Indonesia Library
cover
Emidatul Manzil
"[ABSTRAK
Dosimetri CT scan dapat dilakukan dengan menggunakan konsep CTDI, Monte
Carlo, atau dengan pengukuran langsung dalam fantom fisis. Pengukuran
langsung menggunakan thermoluminescent dosimeter (TLD) merupakan prosedur
yang rumit dan membutuhkan waktu yang lama. Saat ini sudah tersedia film
radiochromic yang dapat digunakan di radiologi. Pada penelitian ini dilakukan
pengukuran distribusi dosis radiasi dalam fantom Rando menggunakan film
Gafchromic XR-QA2 dan TLD. Film Gafchromic XR-QA2 dan TLD dikalibrasi
di CT scanner Siemens Sensation 64. Pengukuran distribusi dosis dengan film
dilakukan pada faktor pitch 0.8, 1.0, dan 1.4. Film Gafchromic XR-QA2
disisipkan diantara slab 22-23 (Film A), 23-24 (Film B), dan slab 24-25 (Film C).
Pengukuran distribusi dosis dengan TLD dilakukan dalam slab nomor 23 dengan
faktor pitch 1.4. Film Gafchromic XR-QA2 yang telah dieksposi dipindai dengan
flatbed scanner Epson Perfection V700 Photo. Dosis serap tulang belakang pada
Film A, Film B, dan Film C yang dieksposi dengan faktor pitch 1.4 secara
berturut-turut adalah 2.0 mGy, 1.9 mGy, dan 2.2 mGy. Berdasarkan profil dosis,
rata-rata dosis serap pada film yang dieksposi dengan faktor pitch 1.0 dan 1.4
secara berturut-turut adalah 8% dan 24% lebih tinggi dibanding rata-rata dosis
serap pada film yang dieksposi dengan faktor pitch 0.8. Rentang dosis hasil
pengukuran dengan TLD adalah (1.9 ± 0.1) – (2.3 ± 0.2) mGy dan rentang dosis
hasil pengukuran dengan film Gafchromic XR-QA2 adalah 1.8 – 2.3 mGy dengan
perbedaan maksimum 10.6%. Perbedaan tersebut masih berada dalam rentang
keakurasian TLD yaitu < 15%. Berdasarkan hasil tersebut, film Gafchromic XRQA2
dapat digunakan untuk pengukuran dosis CT scan selanjutnya.

ABSTRACT
Computed tomography (CT) dosimetry can be approached by using CTDI
method, Monte Carlo computer technique, and direct measurement within
physical phantom. Direct measurement using thermoluminescent dosimeters
(TLDs) is a laborious procedure. Radiochromic film for radiology application was
available. In this study, dose distribution within adult anthropomorphic physical
phantom was measured using TLD and Gafchromic XR-QA2 film. TLD and
Gafchromic XR-QA2 film was calibrated on CT scanner Siemens Sensation 64.
Gafchromic XR-QA2 film was sandwiched between slab Rando phantom number
22-23 (Film A), 23-24 (Film B), and 24-25 (Film C). Pitch factor 0.8, 1.0, and 1.4
were used. TLDs were placed at the holes in the slab number 23 of
anthropomorphic phantom. TLDs were scanned using pitch factor 1.4. After
exposure, Gafchromic XR-QA2 film was digitized using Epson Perfection V700
Photo flatbed scanner. Absorbed dose at vertebra on Film A, Film B, and Film C
which exposed by using pitch 1.4 respectively were 2.0 mGy, 1.9 mGy, and 2.2
mGy. Based on dose profile, average dose of XR-QA2 film which exposed by
using pitch 1.0 and 1.4 respectively were 8% and 24% higher than average dose of
XR-QA2 film which exposed by pitch 0.8. TLDs dose range were (1.9 ± 0.1) –
(2.3 ± 0.2) mGy and Gafchromic XR-QA2 film dose range were 1.8 – 2.3 mGy
with maximum difference 10.6%. The difference is still within the range of TLD
accuracy, < 15%. Based on this result, Gafchromic XR-QA2 film can be used to
measure CT dose, Computed tomography (CT) dosimetry can be approached by using CTDI
method, Monte Carlo computer technique, and direct measurement within
physical phantom. Direct measurement using thermoluminescent dosimeters
(TLDs) is a laborious procedure. Radiochromic film for radiology application was
available. In this study, dose distribution within adult anthropomorphic physical
phantom was measured using TLD and Gafchromic XR-QA2 film. TLD and
Gafchromic XR-QA2 film was calibrated on CT scanner Siemens Sensation 64.
Gafchromic XR-QA2 film was sandwiched between slab Rando phantom number
22-23 (Film A), 23-24 (Film B), and 24-25 (Film C). Pitch factor 0.8, 1.0, and 1.4
were used. TLDs were placed at the holes in the slab number 23 of
anthropomorphic phantom. TLDs were scanned using pitch factor 1.4. After
exposure, Gafchromic XR-QA2 film was digitized using Epson Perfection V700
Photo flatbed scanner. Absorbed dose at vertebra on Film A, Film B, and Film C
which exposed by using pitch 1.4 respectively were 2.0 mGy, 1.9 mGy, and 2.2
mGy. Based on dose profile, average dose of XR-QA2 film which exposed by
using pitch 1.0 and 1.4 respectively were 8% and 24% higher than average dose of
XR-QA2 film which exposed by pitch 0.8. TLDs dose range were (1.9 ± 0.1) –
(2.3 ± 0.2) mGy and Gafchromic XR-QA2 film dose range were 1.8 – 2.3 mGy
with maximum difference 10.6%. The difference is still within the range of TLD
accuracy, < 15%. Based on this result, Gafchromic XR-QA2 film can be used to
measure CT dose]"
2015
T43863
UI - Tesis Membership  Universitas Indonesia Library
cover
Septi Purwaningsih
"[ABSTRAK
Penelitian ini bertujuan untuk mengetahui profil dosis sinar-x Computed
Tomography dengan variasi pitch menggunakan film Gafchromic XR QA2 dan
TLD pada fantom kepala orang dewasa dan kepala pediatrik. Untuk tujuan
tersebut dilakukan pengukuran dan analisis profil dosis di sepanjang sumbu z
rotasi scan pada pusat fantom dan beberapa tepi di kedalaman 1 cm, analisis profil
dosis pada posisi yang sama dengan nilai pitch yang berbeda, dan analisis profil
dosis pada kepala orang dewasa dan kepala pediatrik. Dari pengukuran dan
analisis data diperoleh hasil profil dosis pada scan kepala orang dewasa dan
kepala anak-anak dengan nilai dosis maksimal di tengah, menurun pelan ke arah
tepi dengan tendensi cenderung simetri. Profil dosis dengan variasi nilai pitch,
diperoleh nilai dosis yang semakin menurun dengan bertambahnya nilai pitch.
Profil dosis pada scan kepala orang dewasa memiliki nilai dosis lebih besar dari
pada dosis pada scan kepala pediatrik, karena scan kepala orang dewasa
menggunakan mAs lebih besar. Hasil pengukuran menggunakan TLD diperoleh
data yang bersifat disktrit, namun memiliki pola distribusi dan nilai dosis yang
hampir sama dengan hasil dari pengukuran menggunakan film Gafchromic. Hasil
pengukuran profil dosis menggunakan film Gafchromic didapatkan grafik
kontinu. Nilai dosis maksimum hasil scan didapatkan pada posisi jam 12 dan
minimum pada posisi jam 6. Profil dosis pada pitch 0,75; 1 dan 1,5 mengalami
fluktuasi dosis dengan amplitudo pada pitch 0,75 dan 1,5 mempunyai nilai yang
lebih besar jika dibandingkan dengan amplitudo pada pitch 1.

ABSTRACT
This research aims to check pattern dose profile on the adult and pediatric
head scan. Comparing result measurement dose profile along the z- axis rotation
at a depth 1 cm and center phantom with variety pitch. Measurement using
cylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XR
QA2 Gafchromic film and TLD. Result of research get dose profile adult and
pediatric head scan have same pattern, the maximum dose in the middle and
tendency symmetry in the edge. Value dose proportional with value of pitch. Dose
in the adult head more than dose pediatric head because dose in adult head scan
using bigger mAs. Dose of TLD measurement values obtained are discrete, but
has a distribution and dose values are almost the same as the measurement results
in XR QA2 Gafchromic film. Result of Gafchromic film measurement is continue
graphic. The maximum dose of the scan results at the 12 o'clock position and
minimum at 6 o'clock position. Result of research get fluctuated dose and
amplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1., This research aims to check pattern dose profile on the adult and pediatric
head scan. Comparing result measurement dose profile along the z- axis rotation
at a depth 1 cm and center phantom with variety pitch. Measurement using
cylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XR
QA2 Gafchromic film and TLD. Result of research get dose profile adult and
pediatric head scan have same pattern, the maximum dose in the middle and
tendency symmetry in the edge. Value dose proportional with value of pitch. Dose
in the adult head more than dose pediatric head because dose in adult head scan
using bigger mAs. Dose of TLD measurement values obtained are discrete, but
has a distribution and dose values are almost the same as the measurement results
in XR QA2 Gafchromic film. Result of Gafchromic film measurement is continue
graphic. The maximum dose of the scan results at the 12 o'clock position and
minimum at 6 o'clock position. Result of research get fluctuated dose and
amplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1.]"
2015
T43843
UI - Tesis Membership  Universitas Indonesia Library
cover
Bayu Bagaskara
"Dosis pada LGK Perfexion dihitung untuk setiap tembakan dengan jumlahkan kontribusi dari 192 sumber radiasi yang dipancarkan dari cobalt-60. Secara umum, bentuk tengkorak pasien dimodelkan berdasarkan 24 skull measurement. Namun, karena keterbatasan pengukuran menggunakan 24 ukuran tengkorak, kontur yang dihasilkan perbedaan dari kepala pasien yang sebenarnya berdasarkan citra MRI. Penelitian ini dilakukan untuk distribusi dosis LGK Perfexion menggunakan kontur yang dihasilkan oleh pengukuran manual dan citra CT. Film GAFChromic EBT3 diletakan pada fantom anthropomorphik. Pemindai Epson 10000 XL dan ImageJ digunakan untuk menghasilkan hasil dari pengukuran. Hasil kalkulasi dosis titik menggunakan kontur dari citra CT menunjukan nilai yang lebih baik untuk semua kolimator dan bentuk target yang sama dengan nilai rata deviasi 1,3 ± 0,87, sedangkan jika menggunakan 24 ukuran tengkorak menunjukan nilai rata rata deviasi 4,03 ± 3,73.

The dose on LGK Perfexion is calculated for each shot by adding up the contributions of the 192 radiation sources emitted from the cobalt-60. In general, the patient's skull shape is modeled based on 24 skull sizes. However, due to the limitations of measurements using 24 skull sizes, the contours of the resulting differences from the actual patient's head based on the MRI images. This study was conducted for the dose distribution of LGK Perfexion using contours generated by manual measurements and CT images. The GAFChromic EBT3 film is set on an anthropomorphic ghost. An Epson 10000 XL and an ImageJ scanner were used to generate the measurement results. The result of point dose calculation using CT image contour shows a higher value good for all collimators and the same target shape with a mean deviation value of 1.3 ± 0.87, whereas if using 24 skull sizes it shows a mean deviation value of 4.03 ± 3.73."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ani Sulistyani
"Perhitungan dosis radiasi melalui keluaran metrik 3DRA hanya tersedia pada protokol kontrol kualitas pada CBCT untuk radiologi intervensional. Hal ini dianggap belum andal karena perputaran gantry pada prosedur 3DRA tidak satu lingkaran penuh seperti pada Computed Tomography (CT). Penelitian ini bertujuan untuk mengevaluasi distribusi dosis aksial untuk prosedur 3DRA menggunakan tiga dosimeter relatif: thermoluminescence dosimeter (TLD), Film Gafchromic® XR-QA2, dan Film Gafchromic® XR-RV3. Dosimeter yang terkalibrasi diletakan di dalam fantom in house berbentuk silinder dan dilakukan pengukuran pada pesawat angiografi Philips Allura Xper FD20 menggunakan tiga mode preset yang tersedia.
Hasil pengukuran menggunakan dosimeter relatif dibandingkan dengan hasil pengukuran menggunakan dosimeter absolut untuk mengetahui akurasinya. Dari pengukuran didapatkan bahwa distribusi dosis 3DRA tidak homogen pada seluruh penampang fantom in house. Nilai dosis paling besar berada posisi jam 3 dan jam 9 sedangkan nilai dosis paling rendah berada pada posisi jam 12. Di antara dosimeter yang digunakan, distribusi dosis aksial yang paling akurat diperoleh melalui pengukuran menggunakan Gafchromic® XR-RV3, yang ditunjukkan dengan nilai diskrepansi rata-rata sebesar 33,82%. Selain itu, pengukuran mode Cranial Stent pada posisi jam 12 menunjukkan diskrepansi terkecil, dengan nilai 9,10%.

The calculation of radiation dose for 3DRA output metrics is currently only available in quality control for cone-beam computed tomography (CBCT). This method is considered unreliable because the gantry rotation in the 3DRA procedure is not a full 360 degrees like in CBCT. The objective of this study is to determine the axial dose distribution during the 3DRA procedure using three different relative dosimeters: thermoluminescence dosimeter (TLD), Gafchromic® XR-QA2 Film, and Gafchromic® XR-RV3 Film. The calibrated dosimeters were placed within a cylindrical in-house phantom, and measurements were performed using a Philips Allura Xper FD20 angiography system (in three preset modes).
The output of measurements using a relative dosimeter were compared to those using an absolute dosimeter, with the aim of assessing the accuracy.  It was found that the axial dose distribution in the 3DRA procedure is not evenly distributed across the cross-sectional area of the in-house phantom. The highest dose values were observed at the 3 and 9 o'clock positions, while the lowest dose values were recorded at the 12 o'clock position. Among the dosimeters used, the most accurate axial dose distribution was obtained through measurements using Gafchromic® XR-RV3, as indicated by an average discrepancy value of 33.82%. Additionally, the cranial stent mode measurements at the 12 o'clock position showed the smallest discrepancy, with a value of 9.10%.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Merina Handayani
"Informasi yang akurat dari respon energi thermoluminesensi detector (TLD) sangat penting untuk memahami ketergantungan TLD terhadap respon energi. Respon energi Thermoluminescent Dosimeter menjadi penting karena selama pengukuran radiasi spektrum tidak persis sama dengan spektrum kalibrasi Penelitian ini bertujuan untuk menentukan persamaan estimasi respon dosis TLD pada spektrum sinar x dan untuk mengetahui respon dosis TLD terhadap perubahan energi dengan menggunakan simulasi Monte Carlo. Simulasi dilakukan dengan meletakkan TLD [LiF:MgTi] di tengah sinar x dengan jarak 100cm dari sumber dengan luas lapangan berukuran 10 cm x 10 cm, dan diradiasi menggunakan spektrum monoenergi dari 10 keV sampai 1500 keV dan spektrum sinar x kontinyu. Spektrum sinar x dihitung menggunakan program XCOMP5r pada RQR 2 sampai RQR 10. Dari simulasi, database respon monoenergi yang hasilnya akan digunakan untuk perhitungan estimasi respon dosis TLD. Ada 4 metode perhitungan untuk estimasi respon dosis TLD, berdasarkan perhitungan energi rata-rata, dua model perhitungan tidak memasukkan koreksi stopping power dan dua model perhitungan terakhir memasukkan koreksi stopping power. Perbandingan hasil simulasi Monte Carlo spektrum kontinyu dengan perhitungan metode no. 4, memberikan hasil yang lebih mendekati.

An accurate information of thermoluminesensi detector (TLD) energy response is very important to understand TLD energy response dependence. Thermoluminescent Dosimeter energy response becomes important because during the measurement radiation spectrum is not exactly the same as calibration spectrum. This study aims to determine the dose-response estimation equation of TLD in the X ray spectrum and to understand the dose response of TLD due to energy changes using Monte Carlo simulation. Simulation is done by placing the TLD [LiF: MgTi] in the middle of the X ray beam at 100 cm from the source with 10 cm x 10 cm field size, and irradiated using monoenergy spectrum from 10 keV to 1500 keV and continuous X ray spectrum. The X ray spectrum is calculated using XCOMP5r using RQR 2 to RQR 10. From the simulation, monoenergy response database will obtained used for calculation of TLD dose response estimation. There are 4 calculation methods to estimate TLD dose response, which based on mean energy calculation, two calculation model does not include stopping power correction and the last two calculation model include stopping power correction. Comparison of Monte Carlo simulation result of continuous spectrum with calculation method no. 4, is giving the closest result."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S52508
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kri Yudi Pati Sandy
"Sumber brakhiterapi I-125 pemancar foton energi rendah telah banyak digunakan dalam pengobatan kanker. Sesuai rekomendasi AAPM TG-43, karakteristik dosimetri dari sumber brakhiterapi baru harus ditentukan terlebih dahulu sebelum penggunaan klinis. Dalam penelitian ini telah dilakukan penentuan karakteristik dosimetri dari dua buah sumber I-125 buatan BATAN S1 dan S2 dengan menggunakan Thermolumnescene Dosimeters ( TLD ) dan film gafchromic XR-QA2. Pengukuran fungsi dosis radial dilakukan pada jarak 0.5 cm sampai 10 cm dari pusat sumber. Pengukuran fungsi anisotropi dilakukan pada jarak 2 cm, 3 cm, dan 5 cm dari pusat sumber untuk sudut 0o sampai 90o di setiap kuadran.
Hasil peneltian menunjukkan konstanta laju dosis sumber S1 sebesar 1,07 + 5% cGy.Jam-1.U-1 dan 0,95 + 5% cGy.Jam-1.U-1, sedangkan untuk sumber S2 sebesar 0,94 + 5% cGy.Jam-1.U-1 dan 0,98 + 5% cGy.Jam-1.U-1 berturut-turut untuk pengukuran TLD dan film gafchromic. Fungsi dosis radial sumber S1 dan S2 menurun seiring dengan meningkatnya jarak terhadap sumber dan memenuhi persamaan polinomial orde 5. Hasil fungsi anisotropi menunjukkan bahwa anisotropi distribusi dosis meningkat seiring perubahan sudut menuju arah tegak lurus sumber. Hasil pengukuran karakteristik dosimetri sumber I-125 ini memiliki kesesuaian dengan hasil simulasi Monte Carlo EGSnrc dan memiliki pola yang serupa dengan karakteristik sumber I-125 komersil buatan IsoAid dan Echoseed.

I-125 brachytherapy sources with low photon energies have been widely used in treating tumors. According to AAPM TG-43 recommendations, dosimetric characteristic of the new brachytherapy sources should be determined before clinical use. In this study, dosimetric characteristic of two I-125 manufacturing by BATAN with notation S1 and S2 have been determined by measurement using TLD and gafchromic XR-QA2 film. The radial dose function measurements were performed at distances ranging from 0.5 to 10 cm from the source center. The anisotropy functions were measured at distances of 2, 3, and 5 cm from the source center for angles ranging from 0 to 90 degree in all quadrants.
The results indicated a dose rate constant of 1.07 + 5% cGy.h-1.U-1 and 0.95 + 5% cGy.h-1.U-1 for S1 and 0.94 + 5% cGy.h-1.U-1 and 0.98 + 5% cGy.h-1.U-1 for S2 with using TLD and film, respectively. Radial dose function for S1 and S2 decreased along with increace of distance from source and meet the 5th order polynomial equation. The anisotropy function result shows that the anisotropy in dose distribution increased along the source axis. This measurement data are in agreement with EGSnrc Monte Carlo result and have a similar pattern with IsoAid and Echoseed commercial I-125 source.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
T43696
UI - Tesis Membership  Universitas Indonesia Library
cover
Lenny Kurnianingsih
"ABSTRAK
Dengan menggunakan TLD dan dosimeter dioda EDD - 53G, telah diukur dosis
organ kritis mata, tiroid, medula spinalis , dan gonad pada berbagai perlakuan
radioterapi dengan sinar X 6 MV. Pengukuran dilakukan pada fantom rando yang
diberi simulasi perlakuan radioterapi dengan berbagai jenis kanker, utamanya kanker
nasofaring. Perencanaan simulasi terapi 3 D dilakukan dengan TPS ISIS berdasarkan
data hasil pengamatan pada beberapa pasien kanker nasofaring yang telah menjalani
radioterapi di RSPAD. Perlakuan diberikan dengan 2 lapangan plan parallel dan teknik
SAD (source axis distance), ukuran lapangan radiasi 18.5 x 17 cm2, dosis preskripsi 2
Gy/fraksi. Sesuai dengan perlakuan pada pasien, kemudian lapangan diperkecil untuk
melindungi medulla spinalis, menjadi 9 x 16 cm2. Dengan cara yang sama, dosis organ
kritis ditentukan dari simulasi radioterapi kanker paru, tulang bahu, abdomen, pelvis
dan tulang paha. Perencanaan setiap perlakuan diakukan berdasarkan data seorang
pasien yang telah menjalani radioterpi di RSPAD . Pada umumnya dosis organ kritis
yang berjarak 0 – 4 cm dari tepi lapangan berbeda dengan hasil kalkulasi TPS sampai
61% bila diukur dengan TLD, dan berbeda sampai 80% bila diukur dengan diode.
Untuk organ yang terletak relatif lebih jauh dari tepi lapangan radiasi, hasil pengukuran
dengan kedua dosimeter menunjukkan hasil sama, berbeda sampai lebih 100% dengan
kalkulasi TPS. Dosis pada pasien 5000 cGy, maka mata menerima dosis mencapai 209
cGy pada perlakukan kanker nasofaring dan mencapai 400 cGy pada perlakukan kanker
otak. Organ kritis tiroid dimungkinkan menerima dosis dari perlakuan kanker paru,
kanker nasofaring, dan kanker tulang bahu, berturut turut mencapai 284 cGy, 192 cGy,
dan 312 cGy. Organ kritis Gonad pada perlakuan radioterapi kanker abdomen menerima
dosis sebesar 524 cGy dan kanker sarkoma tulang paha mencapai 372 cGy.

ABSTRACT
By using TLD and diode dosimeter EDD - 53G, critical organ doses were
measured eye, thyroid, spinal cord, and gonads at various radiotherapy treatment with 6
MV X-rays. Measurements were taken at rando phantom given radiotherapy treatment
simulations with various types of cancer, especially nasopharyngeal cancer. 3 D
treatment planning simulations performed with ISIS TPS based observed data on some
of nasopharyngeal cancer patients who had undergone radiotherapy in the army
hospital. Treatment was given with 2 field parallel plan and technique of SAD (source
distance axis), the radiation field size 18.5 x 17 cm2, prescription dose 2 Gy / fraction.
In accordance with the patient's treatment, then the field is reduced to protect the spinal
cord, at 9 x 16 cm2. In the same way, the dose of the critical organ is determined from
the simulation radiotherapy of lung cancer, bone shoulder, abdomen, pelvis and femur.
Planning any transactions are carried out based on the data treatment of a patient who
had undergone radiotherapy at the RSPAD. In general, the critical organ dose within 0-4
cm from the edge of the field in contrast to the results of calculations TPS to 61% when
measured with the TLD, and vary up to 80% when measured with the diode. For an
organ that is located relatively far from the edge of the radiation field, with both
dosimeter measurements showed similar results, approximately over 100% different
from the TPS calculations. The dose given to patient at 5000 cGy, the eyes received
dose until 209 cGy at simulation nasofaring cancer and until 400 cGy at simulation
brain cancer. Critical organs received doses of thyroid possible treatment of lung cancer,
nasofaring cancer, and shoulder bone cancer, the dose received in a row to reach 284
cGy, 192 cGy, and 312 cGy. Gonad organ critical in the abdomen cancer radiotherapy
treatment received a dose of 524 cGy and bone sarcoma cancer at 372 cGy."
Universitas Indonesia, 2013
T35038
UI - Tesis Membership  Universitas Indonesia Library