Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 164848 dokumen yang sesuai dengan query
cover
Vera Rahmawati
"ABSTRAK
Latar Belakang. Atelektasis merupakan komplikasi pernapasan perioperatif yang sering terjadi hingga 24 jam pascaoperatif, namun dapat bertahan hingga beberapa hari. Penggunaan PEEP dapat membuka alveolus yang kolaps pascaoperatif. Penelitian ini berusaha membandingkan efek PEEP 5 cmH20 dan 10 cmH2O terhadap distribusi ventilasi pada pasien pascaoperatif menggunakan EIT.
Metoda. Uji klinis acak ini dilakukan di RS Cipto Mangunkusumo terhadap 35 pasien operasi kranioktomi dan laparotomi elektif (usia 18-60 tahun, durasi bedah > 3 jam, paru normal). Subjek dirandomisasi ke dalam 2 kelompok intervensi: ventilasi mekanik pascaoperatif PEEP 5 cmH20 (PEEP-5) dan PEEP 10 cmH2O (PEEP-10). Hipotesis penelitian adalah distribusi ventilasi PEEP-10 lebih baik dibandingkan PEEP-5. Parameter ∆TIV, ∆EELI (global dan regional) dan CR diambil dari monitor EIT PulmoVista 500®.
Hasil. Nilai ∆TIV antara bagian paru anterior dan posterior berbeda bermakna secara statistik pada menit ke-20 (p=0,012), namun masih ada subjek kelompok PEEP-5 dengan distribusi ventilasi tidak homogen hingga 1 jam pengukuran. Nilai ∆EELI global dan regional dalam 1 jam secara statistik bermakna dengan nilai p<0,05. Nilai ∆CR (anterior dan posterior) bermakna secara statistik (p=0,000) dalam 1 jam. Tidak ditemukan perbedaan ratio PF, lama intubasi dan lama rawat di UPI. Tidak ditemukan komplikasi paru/ekstraparu lain dan mortalitas.
Simpulan. Distribusi ventilasi berdasarkan gambaran EIT antara penggunaan PEEP 10 cmH2O dan PEEP 5 cmH2O tidak berbeda secara statistik dalam 1 jam penggunaan ventilasi mekanik pascaoperatif. Distribusi ventilasi hanya bermakna secara statistik pada menit ke-20.
pernapasan perioperatif

ABSTRACT
Background. Atelectasis is the most common perioperative respiratory complications up to 24 hours postoperatively, but can last up to several days. PEEP can open postoperative alveolar collapse. We determined to compare the effect of PEEP 5 cmH20 and 10 cmH2O on distribution of ventilation in patients postoperatively using EIT.
Method. This randomized clinical trial conducted in Cipto Mangunkusumo Hospital to 35 patients underwent elective craniotomy and laparotomy (18-60 years of age, surgery> 3 hours, normal lung). Subjects were randomized into two intervention groups: postoperative mechanical ventilation PEEP 5 cmH20 (PEEP-5) and 10 cmH2O PEEP (PEEP-10). The hypothesis is distribution of ventilation PEEP-10 is better than PEEP-5. Parameter ΔTIV, ΔEELI (global and regional) and ΔCR were taken from a monitor EIT PulmoVista 500®.
Results. ΔTIV values ​​between anterior and posterior parts of lung statistically significant difference in the 20th minute (p=0.012), but there is still a subject of the PEEP group-5 which has a non-homogeneous distribution of ventilation up to 1 hour of measurement. The value of ΔEELI (global and regional ) in 1 hour statistically significant with p <0.05. ΔCR value (anterior and posterior) was statistically significant (p = 0.000) in 1 hour. No differences found for PF ratio, length of intubation and duration of hospitalization in ICU. No pulmonary/extrapulmonaary complications and mortality were found.
Conclusion. Distribution of ventilation based EIT imaging between the use of PEEP 10 cmH2O and PEEP 5 cmH2O do not differ statistically within 1st hour of the postoperative mechanical ventilation. Distribution of ventilation is statistically significant only in the 20th minute.;Background. Atelectasis is the most common perioperative respiratory complications up to 24 hours postoperatively, but can last up to several days. PEEP can open postoperative alveolar collapse. We determined to compare the effect of PEEP 5 cmH20 and 10 cmH2O on distribution of ventilation in patients postoperatively using EIT.
Method. This randomized clinical trial conducted in Cipto Mangunkusumo Hospital to 35 patients underwent elective craniotomy and laparotomy (18-60 years of age, surgery> 3 hours, normal lung). Subjects were randomized into two intervention groups: postoperative mechanical ventilation PEEP 5 cmH20 (PEEP-5) and 10 cmH2O PEEP (PEEP-10). The hypothesis is distribution of ventilation PEEP-10 is better than PEEP-5. Parameter ΔTIV, ΔEELI (global and regional) and ΔCR were taken from a monitor EIT PulmoVista 500®.
Results. ΔTIV values ​​between anterior and posterior parts of lung statistically significant difference in the 20th minute (p=0.012), but there is still a subject of the PEEP group-5 which has a non-homogeneous distribution of ventilation up to 1 hour of measurement. The value of ΔEELI (global and regional ) in 1 hour statistically significant with p <0.05. ΔCR value (anterior and posterior) was statistically significant (p = 0.000) in 1 hour. No differences found for PF ratio, length of intubation and duration of hospitalization in ICU. No pulmonary/extrapulmonaary complications and mortality were found.
Conclusion. Distribution of ventilation based EIT imaging between the use of PEEP 10 cmH2O and PEEP 5 cmH2O do not differ statistically within 1st hour of the postoperative mechanical ventilation. Distribution of ventilation is statistically significant only in the 20th minute.;Background. Atelectasis is the most common perioperative respiratory complications up to 24 hours postoperatively, but can last up to several days. PEEP can open postoperative alveolar collapse. We determined to compare the effect of PEEP 5 cmH20 and 10 cmH2O on distribution of ventilation in patients postoperatively using EIT.
Method. This randomized clinical trial conducted in Cipto Mangunkusumo Hospital to 35 patients underwent elective craniotomy and laparotomy (18-60 years of age, surgery> 3 hours, normal lung). Subjects were randomized into two intervention groups: postoperative mechanical ventilation PEEP 5 cmH20 (PEEP-5) and 10 cmH2O PEEP (PEEP-10). The hypothesis is distribution of ventilation PEEP-10 is better than PEEP-5. Parameter ΔTIV, ΔEELI (global and regional) and ΔCR were taken from a monitor EIT PulmoVista 500®.
Results. ΔTIV values ​​between anterior and posterior parts of lung statistically significant difference in the 20th minute (p=0.012), but there is still a subject of the PEEP group-5 which has a non-homogeneous distribution of ventilation up to 1 hour of measurement. The value of ΔEELI (global and regional ) in 1 hour statistically significant with p <0.05. ΔCR value (anterior and posterior) was statistically significant (p = 0.000) in 1 hour. No differences found for PF ratio, length of intubation and duration of hospitalization in ICU. No pulmonary/extrapulmonaary complications and mortality were found.
Conclusion. Distribution of ventilation based EIT imaging between the use of PEEP 10 cmH2O and PEEP 5 cmH2O do not differ statistically within 1st hour of the postoperative mechanical ventilation. Distribution of ventilation is statistically significant only in the 20th minute."
2015
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Cynthia Afriany
"Latar Belakang: Laparoskopi merupakan prosedur yang menguntungkan pada operasi transplantasi ginjal . Namun teknik ini dapat menyebabkan perubahan pada sistem pernafasan. Pengaturan volume tidal merupakan salah satu strategi proteksi untuk mencegah komplikasi paru pascaoperatif. Penelitian ini berusaha membandingkan efek volume tidal 6 mL/kgbb dan 10 mL/kgbb terhadap distribusi ventilasi pada pasien donor transplantasi ginjal yang menjalani nefrektomi per laparoskopi menggunakan EIT.
Metoda: Uji klinis ini dilakukan di Instalasi Bedah Pusat RSUPN Cipto Mangunkusumo dan ruang operasi RSCM Kencana Jakarta terhadap 30 pasien donor transplantasi ginjal yang menjalani laparoskopi nefrektomi. Subjek dirandomisasi ke dalam 2 kelompok intervensi: ventilasi mekanik intraoperatif dengan volume tidal 6 mL/kgbb dan 10 mL/kgbb. Hipotesis penelitian adalah distribusi ventilasi volume tidal 6 mL/kg lebih baik dibandingkan 10 mL/kg. Parameter yang dinilai adalah ?TIV, ?EELI global dan regional dan ?CR diambil dari monitor EIT PulmoVista 500.
Hasil: Nilai ∆TIV paru dependen dan nondependen antara kedua kelompok berbeda bermakna secara statistik pada posisi supine pascadesuflasi (p =0,008), dimana volume tidal 6 mL/kgbb menunjukkan distribusi ventilasi tidak homogen. Nilai ∆EELI global dan regional volume tidal 10 mL/kg lebih tinggi dan bermakna secara statistik pada posisi lateral dekubitus sebelum insuflasi (p <0,005). Tidak ditemukan perbedaan bermakna nilai ∆CR (paru dependen dan nondependen).
Simpulan. Pemberian volume tidal 6 mL/kgbb tidak memberikan gambaran distribusi ventilasi yang lebih baik dibandingkan dengan volume tidal 10 mL/kgbb pada pasien donor ginjal yang menjalani operasi laparoskopi nefrektomi berdasarkan parameter EIT.

Background: Laparoscopy is a procedure that is profitable on a kidney transplant operation. However, this technique may cause changes in the respiratory system. Tidal volume setting is one of protection strategies for preventing pulmonary complications postoperative. This study attempted to compare the effects of tidal volume 6 mL kgbw and 10 mL kgbb kgbw against distribution of ventilation in kidney transplant donor patients who underwent laparoscopic nephrectomy using EIT.
Method: This randomized clinical trial conducted in the Surgical Center Installation RSUPN Cipto Mangunkusumo and operating room RSCM Kencana Jakarta against 30 kidney transplant donor patients who underwent laparoscopic nephrectomy. Subjects were randomized into two intervention groups mechanical ventilation with intraoperative tidal volume 6 mL kgbw and 10 mL kgbw. The hypothesis is distribution of ventilation tidal volume 6 mL kgbw is better than 10 mL kgbw. Parameter TIV, EELI global and regional and CR were taken from a monitor EIT PulmoVista 500.
Result: The value of TIV between dependent and nondependent parts of lung statistically significant difference on postdesuflation supine position p 0,008 , where the tidal volume of6 mL kgbw indicates distribution of ventilation is not homogenous. The value of EELI global and regional tidal volume 10 mL kg is higher and meaningful statistically on lateral decubitus before insuflation p 0,005 . There is no meaningful difference in CR value the dependent and nondependent parts of lung.
Conclusion: Tidal volume 6 mL kgbw does not give a better distribution of ventilation compared with 10 mL kgbw in kidney donor patient undergoing laparoscopic nephrectomy based on the parameters of the EIT.Keywords Distribution of ventilation, EIT, kidney donor, laparoscopic nephrectomy, intraoperative volume tidal.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2016
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Lia Miranda
"Tesis ini disusun untuk mengetahui data profile MEP dan APB serta efek latihan penguatan otot ekspirasi dengan perangkat PEP terhadap MEP dan APB pada lansia sedentary. Penelitian menggunakan desain uji acak terkontrol (randomized control trial) dengan latihan PLB sebagai kontrol. Subjek penelitian adalah lansia berusia lebih dari 60 hingga 75 tahun, sedentary, MocaINA ≥ 26, tidak merokok dalam 5 tahun terakhir, memiliki care giver, dapat berbahasa Indonesia, nilai spirometri normal atau abnormal, dapat memahami dan mempraktekkan dengan benar penggunaan alat PEP dan latihan PLB, bersedia mengisi log book dengan benar dan teratur dan bersedia mengikuti penelitian secara sukarela serta menandatangani lembar persetujuan. Semua subjek penelitian (n=72) yaitu 35 orang dari kelompok PEP dan 37 orang dari kelompok PLB dilakukan penilaian MEP dan APB pada awal minggu pertama serta penentuan intensitas latihan yaitu 50% 1 RM pada kelompok PEP. Latihan dilanjutkan sebagai home program selama 4 minggu dengan kelompok PEP melakukan kunjungan setiap minggu untuk menentukan intensitas latihan yaitu 50% dari 1 RM yang baru sedangkan kelompok latihan PLB melakukan kunjungan pada minggu ketiga untuk evaluasi. Selama penelitian terdapat 6 subjek penelitian yang drop out, 2 dari kelompok PEP dan 4 dari kelompok PLB. Pada awal minggu kelima dilakukan kembali penilaian MEP dan APB pada kedua kelompok didapatkan kenaikan MEP dan APB yang secara klinis dan statistik signifikan ( p < 0,001) dengan kenaikan yang lebih besar pada kelompok PEP dan secara statistik kenaikan pada kelompok PEP jika dibandingkan dengan kenaikan yang terjadi pada kelompok PLB adalah signifikan (p < 0,001). Kesimpulan penelitian ini adalah data profile MEP lansia sedentary adalah rata-rata 48,73 ± 19,14 cmH2O pada kelompok PEP dan 40,61 ± 14,49 cmH2O pada kelompok PLB sedangkan data profile APB pada kelompok PEP rata-rata 268,64 ± 97,28 l/m dan 274,15 ± 79,25 l/m pada kelompok PLB. Latihan pernafasan dengan menggunakan perangkat PEP dapat meningkatkan nilai MEP dan APB pada lansia sedentary dimana didapatkan nilai median Δ MEP adalah 23 (10 – 38) cmH2O dan nilai median Δ APB adalah 40 (15 – 135) l/m dan secara statistik bermakna dengan nilai p < 0,001.

This Thesis was aimed to determine the profile data of MEP and PCF as well as the effect of expiratory muscle strength training with PEP to MEP and PCF in sedentary elderly. The design was randomized control trial with PLB exercise as control. The subjects were eldery, ages more than 60 to 75 years old who were sedentary with MocaINA ≥ 26, no active history of cigarette smoking in the last 5 years, had assistance of care giver, actively speaking in Bahasa Indonesia, had normal or abnormal spirometry value, understood and were able to practice PEP or PLB exercise correctly, filling out log book regularly and correctly and voluntarily willing to join the research and signed signed inform consent form. All subjects (n=72) consisted of 35 subjects in PEP group and 37 subjects in control group (assigned to do PLB exercise). In the beginning of the first week the subject’MEP and PCF values were obtained and the intensity of exercise using PEP was determined at 50% of 1 RM. Exercise was continued as a home program for 4 weeks with the PEP group asked to come weekly to cardiorespiratory outpatient clinic in rehabilitation department to determine a new exercise intensity of 50% of the new 1 RM. While subjects in the PLB group came to cardiorespiratory outpatient clinic at the beginning of the third week to be evaluated. During this research 6 subjects dropped out, 2 subjects from PEP group and 4 subjects from PLB group. At the beginning of fifth week, MEP and PCF values were reassessed and the result demonstrated an increase in both MEP and PCF values (clinically and statistically) in both groups with a greater increase in PEP group. The increase in MEP and PCF values in PEP group was significant in comparison to the PLB group (p < 0,001. The study concluded that average profile data of MEP in sedentary elderly were 48,73 ± 19,14 cmH2O in PEP group and 40,61 ± 14,49 cmH2O in PLB group whereas average profile data of PCF in sedentary elderly were 268,64 ± 97,28 l/m and 274,15 ± 79,25 l/m in PLB group. Expiratory muscle strength training with PEP could increase MEP and PCF values in sedentary elderly with median Δ MEP was 23 (10 – 38) cmH2O and median Δ PCF was 40 (15 – 135) l/m and the increase was statistically significant with p < 0,001."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Okta Hariza
"Rehabilitasi pasien penyakit paru obstruktif kronik (PPOK) yang stabil bertujuan untuk mengurangi sesak, meningkatkan toleransi latihan, dan meningkatkan status kesehatan. Pada dekade terakhir banyak dikembangkan teknik terapi mandiri salah satunya adalah menggunakan perangkat positive expiratory pressure (PEP). Penelitan ini bertujuan untuk menilai efektivitas latihan pernapasan menggunakan perangkat PEP pada volume ekspirasi paksa detik pertama (VEP1), kapasitas fungsional, dan kualitas hidup pada pasien PPOK. Desain penelitian yang digunakan yaitu studi intervensional prospektif yang membandingkan efek sebelum dan sesudah latihan pernapasan menggunakan PEP selama 8 minggu. Subjek yang menyelesaikan penelitian sebanyak 20 orang. Latihan pernapasan dilakukan dua kali sehari dengan durasi 15 menit pada masing-masing sesi latihan. Tekanan yang digunakan disesuaikan dengan kemampuan pasien yaitu inspirasi berbanding ekspirasi 1:3. Tekanan ditentukan sebelum memulai latihan dan dievaluasi setiap dua minggu. Hasil keluaran yang dinilai adalah nilai VEP1, kapasitas fungsional yang diukur dengan kecepatan berjalan dalam uji jalan 4 meter dan kualitas hidup yang diukur dengan kuesioner St. George s Respiratory Questionnaire (SGRQ). Nilai VEP1 sebelum intervensi adalah 1369,5±569,63 ml dan sesudah sebesar 1390±615,01 ml (p=0.585). Kecepatan berjalan sebelum intervensi 1,43±0.31 m/s dan sesudah 1,56±0,40 m/s (p=0.248). Skor kuesioner SGRQ domain gejala terdapat penurunan dari rerata 44,00±17,88% menjadi 25,31±14,06% (p=0.000), domain aktivitas dari rerata 54,22±28,18% menjadi 40,38±24,25% (p=0.006), domain dampak dari 32,83% (0,00-67,46) menjadi 16,32% (0,00-61,33) (p=0.002), dan skor total dari 39,46% (6,30-75,42) menjadi 25,96% (5,24-61,34) (p=0.001). Peningkatan kecepatan berjalan dan perbaikan skor SGRQ memenuhi nilai minimum clinically important difference (MCID). Latihan pernapasan menggunakan perangkat PEP selama 8 minggu dapat meningkatkan nilai VEP1, kapasitas fungsional dan kualitas hidup pasien PPOK.

Rehabilitation of stable chronic obstructive pulmonary disease (COPD) aims to reduce dyspnoe, increase exercise tolerance, and improve health status. In the last decade, many independent therapy techniques have been developed, one of them is positive expiratory pressure (PEP). The aim of this study was to assess the effectiveness of breathing exercises using a PEP device on Forced Expiratory Volume in 1 second (FEV1), functional capacity, and quality of life in COPD patients. The study design was a prospective interventional studies that compared the effects before and after breathing exercises using PEP for 8 weeks. Twenty subjects completed the study. Breathing exercises were carried out twice a day, 15 minutes duration at each session. The pressure used is adjusted to the patient's ability, reaching inspiration to expiration ratio of 1:3. Pressure was determined before starting the exercise and evaluated every two weeks. The outcome were FEV1, functional capacity measured by walking speed in the 4 meter gait speed assesment and quality of life as measured by the St. George s Respiratory Questionnaire (SGRQ). FEV1 ​​before intervention were 1369,5±569,63 ml and after 1390±615,01 ml (p=0.585). Walking speed before intervention was 1,43±0,31 m/s and after 1,56±0,40 m/s (p=0,248). The symptom domain SGRQ questionnaire score has a decrease from 44,00±17,88% to 25,31±14,06% (p=0,000), the activity domain from 54,22±28,18% to 40,38±24,25% (p=0.006), the impact domain of 32,83% (0,00-67,46) to 16,32% (0,00-61,33) (p=0,002), and the total score of 39,46% (6,30-75,42) to 25,96% (5,24-61,34) (p=0.001). Increase in walking speed and SGRQ score exceed the minimum clinically important difference (MCID). Breathing exercises using a PEP device for 8 weeks can increase FEV1, functional capacity and quality of life of COPD patients."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
T57620
UI - Tesis Membership  Universitas Indonesia Library
cover
Yustika Rini
"Tuberkulosis paru dapat menyebabkan perubahan permeabilitas lapisan pleura akibat aktivitas inflamasi mycobacterium tuberculosis sehingga terjadinya akumulasi cairan di rongga pleura dan mengganggu pengembangan paruparu. Karakteristik efusi pleura ditemukan sebanyak 87% dari 119 kasus efusi pleura disebabkan oleh penyakit pada rongga toraks (lokal) seperti TB. Sesak napas manifestasi klinis paling umum namun sering melemahkan dan secara signifikan mengganggu kualitas hidup. Latihan napas dapat menjadi salah satu intervensi keperawatan mandiri untuk mengurangi sesak napas. Karya ilmiah akhir ners ini akan menganalisis asuhan keperawatan pasien Ny AA (46 tahun) dengan masalah keperawatan pola napas tidak efektif dengan intervensi latihan napas Bubble Positive Expiratory Pressure. Cara kerja Bubble Positive Expiratory Pressure membuat gelembung dalam air diharapkan membuat tekanan positif yang menahan saluran udara dan membantu lebih banyak udara masuk dan keluar dari paru-paru. Trend perubahan fungsi pernapasan setelah melakukan Bubble Positive Expiratory Pressure dapat terlihat dengan sesak napas dari skala 7/10 menjadi 4/10, frekuensi napas dari 24x/menit menjadi 20x/menit, adanya penggunaan otot bantu napas menjadi minimal, dan tipe pernapasan dari nasal kanul 5 liter/menit dengan Spo2 96% menjadi room air dengan Spo2 98%. Latihan napas Bubble Positive Expiratory Pressure dapat menjadi intervensi keperawatan mandiri yang dapat dilakukan pada pasien dengan masalah paru-paru.

Pulmonary tuberculosis can cause changes in the permeability of the pleural layer due to the inflammatory activity of Mycobacterium tuberculosis, resulting in fluid accumulation in the pleural cavity and disrupting lung development. Characteristics of pleural effusion found as much as 87% of 119 cases of pleural effusion caused by diseases of the thoracic cavity (local) such as TB. Shortness of breath is the most common clinical manifestation but is often debilitating and significantly impairs quality of life. Breathing exercises can be one of the independent nursing interventions to reduce shortness of breath. This final scientific paper will analyze the nursing care of the patient Mrs. AA (46 years) with nursing problems with ineffective breathing patterns with Bubble Positive Expiratory Pressure breathing exercises. How Bubble Positive Expiratory Pressure works by creating bubbles in the water is expected to create positive pressure that holds the airways and helps more air in and out of the lungs. The trend of changes in respiratory function after doing Bubble Positive Expiratory Pressure can be seen with shortness of breath from a scale of 7/10 to 4/10, respiratory rate from 24x/minute to 20x/minute, minimal use of accessory muscles, and type of breathing from nasal cannul 5 liters/minute with oxygen saturation 96% to room air with oxygen saturation 98%. Bubble Positive Expiratory Pressure breathing exercises can be an independent nursing intervention that can be done in patients with lung problems."
Depok: Fakultas Ilmu Keperawatan Universitas Indonesia, 2022
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Deki Setiyanto
"Telah dibuat prototype alat system electrical impedance tomografi untuk mendeteksi struktur internal dari suatu medium menggunakan frekuensi tunggal, medium itu berupa phantom berdiameter 130 mm, dengan sensor berupa plat tembaga didalam permukaan phantom itu sebanyak 16 buah dengan ketebalan 0.1 mm. Phantom dihubungkan dengan rangkaian demultiplekser untuk menginjeksikan arus constant dan multiplekser untuk pengukuran tegangan dengan kabel coaxial. Signal arus dihasilkan dari voltage controlled oscillator berupa tegangan sinusoidal dengan frekuensi 100 kHz menggunakan XR2206CP dan dikonversi menjadi arus menggunakan voltage control current source dengan rangkaian Howland secara kontinu. Arus sinusoidal itu dikirim ke demultiplekser yang dikendalikan oleh microcontroller Atmega 128 dan multiplekser memilih elektroda yang harus diukur tegngan pada elektroda. Hasil penseleksian elektroda ini kemudian diambil oleh osiloskop digital. Osiloskop ini diamati dengan PC melalui software LabVIEW yang dikembangkan dalam penulisan ini. Format data hasil pengamatan ini berupa format Excel untuk diintegrasi dengan proses open source EIDORS untuk menghasilkan citra tomografi. Model phantom yang dibuat ada 5 macam model, masing-masing dengan posisi yang berbeda diperoleh pencitraan yang cukup mendekati model tersebut.

A prototype of electrical impedance tomography system for detecting the internal structure of a medium using a single frequency has been made with, the medium of phantom with 130 mm diameter, with the surface sensor in the phantom of copper plate as many as 16 pieces with 0.1 mm thick. The Phantom was connected to the circuit demultiplexer to inject constants current and multiplexer for voltage measurement with coaxial cable connector. Current signal resulted from Voltage- Controlled Oscillator(VCO) using XR2206CP to produce sinusoidal voltage signal with 100 kHz frequency and then converted into current using a Voltage Control Current Source (VCCS) with a Howland Circuit. Sinusoidal currents were delivered to demultiplexer controlled by the microcontroller Atmega 128 and multiplexer to select voltage measured from phantom. Results from electrode was taken by a digital oscilloscope. Digital Oscilloscope is observed with a PC via LabVIEW software. These observation data was writen with Excel format to be integrated with the open source EIDORS to produce tomographic images. Phantom models have 5 model and different models, each with different positions obtained by imaging was adequate for imaging the model."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
S1435
UI - Skripsi Open  Universitas Indonesia Library
cover
Achmad Ansory
"Electrical Impedance Tomography EIT adalah metode pencitraan yang mampu memperkirakan distribusi impedansi listrik di bagian dalam objek. Sistem EIT yang dibuat lebih sederhana dan portabel berbasis Mikrokontroler dan menggunakan 32 elektroda. Dari pasangan elektroda diinjeksikan arus bolak-balik 3 mA dan diukur beda voltase pada pasangan elektroda lain. Data pengukuran voltase dikirim ke MATLAB dan software EIDORS, data tersebut akan direkonstruksi menjadi citra objek dua dimensi. Objek dengan ukuran 4 cm2 atau lebih dapat direkonstruksi oleh sistem EIT dengan noise citra skala normal. Posisi objek dicitrakan cukup akurat dengan pergeseran rata-rata sebesar 0,69 cm namun luas objek belum dapat dicitrakan dengan akurat. Keakurasian citra objek lebih besar ketika letak objek dekat dengan elektroda, ukuran objek besar, dan diinjeksikan arus dengan frekuensi 100KHz dan 200KHz.

Electrical Impedance Tomography EIT is an imaging method that is able to estimate electrical impedance distribution inside of an object. EIT system is developed by using 32 electrodes and microcontroller based. From a pair of electrodes, sinusiodal curent 3mA is injected and diffrence voltage of another pair of electrodes is measured. Voltage measurement datas is sent to MATLAB and EIDORS software, the data is used to reconstruct two dimensions image. An Object size of 4 cm2 or more can be recontructed by EIT system with normal noise. Object position is high accurately reconstructed with mean displacement 0.69 cm but object area cannot be accurately reconstructed. Object rsquo s image more accurate when object rsquo s position closer to electrodes, bigger object rsquo s size, and current injected with frequency 100 KHz and 200KHz."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T46853
UI - Tesis Membership  Universitas Indonesia Library
cover
Tommy Sugiarto
"Electrical Impedance Tomography (EIT) merupakan salah satu teknik tomografi yang memanfaatkan distribusi konduktivitas dari objek yang diamati. Teknik pencitraan ini tidak menghasilkan radiasi karena menggunakan arus listrik bolak-balik orde lemah dan berfrekuensi tinggi. Arus akan diinjeksikan kedalam phantom yang berisi 16 elektroda yang terbuat dari tembaga yang dilapisi lapisan silver conductive paint. Tembaga yang digunakan berukuran 4 x 2 cm dengan ketebalan 0.5 mm. Tegangan akan diukur pada elektroda lainnya yang kemudian data tersebut akan diolah oleh perangkat lunak EIDORS menjadi hasil rekonstruksi citra. Pengontrolan elektroda yang akan diinjeksi arus dan diukur teganganya dilakukan oleh 16 channel multiplekser dan demultiplekser. Proses akuisisi data pada penelitian ini menggunakan perangkat NI ELVIS II dengan bantuan perangkat lunak LabVIEW. Sistem ini mampu melakukan proses rekonstruksi citra untuk objek plastik berbentuk silinder dengan diameter terkecil 2.5 cm.

Electrical Impedance Tomography is one of tomography method which is based on distribution of electrical conductivity from the object. This method doesn’t produce harmful radiation because it is use constant low amplitude and high frequency AC current. On this method current will be injected to the phantom by 16 electrodes which made from copper that coated by silver conductive paint. The copper’s size is 4 x 2 cm and 0.5 mm thickness. Voltage will be measured on adjacent electrodes and then EIDORS will proccess it into image reconstruction. Data aqcuisition system are processed by NI ELVIS II with LabVIEW software. This system is able to process image reconstruction from cylindrical plastic object which has minimum size 2.5 cm of diameter"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S57839
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arbariyanto Mahmud Wicaksono
"Pemanfaatan teknologi Electrical Impedance Tomography (EIT) dalam pencitraan medis merupakan salah satu upaya dalam bidang teknologi biomedis untuk menyediakan modalitas pencitraan yang cepat, aman, serta murah. Teknologi ini menarik perhatian peneliti dikarenakan kemampuan pencitraan menggunakan komponen yang sederhana tanpa memanfaatkan radiasi mengionisasi. Faktor yang menghambat pengadopsian dari teknologi EIT merupakan biaya perangkat instrumentasi pengukuran impedansi yang mahal dan diperlukannya algoritma yang kompleks dalam melakukan rekonstruksi gambar. Sebagian besar sistem EIT yang tersedia melakukan rekonstruksi gambar setelah keseluruhan pengukuran selesai dilakukan sehingga pencitraan tidak dilakukan dalam waktu nyata. Penulis berharap menyediakan perangkat sistem EIT sederhana yang mudah dikembangkan dan dapat melakukan pengukuran serta rekonstruksi gambar dalam waktu singkat. Penulis melakukan penelitian melalui proses perancangan dan perangkaian sistem EIT yang memanfaatkan Arduino beserta perangkat lunak MATLAB. Seluruh perangkat lunak dari sistem diintegrasikan pada perangkat lunak MATLAB untuk mengeliminasi keterlambatan akibat pemindahan data antar aplikasi. Algoritma EIDORS digunakan untuk membentuk gambar rekonstruksi. Pengukuran impedansi pada sistem dilakukan menggunakan 16 buah elektrode dengan metode pengukuran four-terminal-sensing pada frekuensi 50 kHz. Sistem EIT yang diusulkan berhasil mengintegrasikan algoritma EIDORS-MATLAB dengan Arduino untuk melakukan rekonstruksi pencitraan menggunakan sistem yang sederhana.

The adoption of Electrical Impedance Tomography (EIT) in medical imaging is one of the innovation of biomedical engineering to provide a faster, safer and cheaper imaging modality. This technology garner interest by researcher due to its ability to provide imaging using simple component without the use of ionizing radiation. A barrier that halted the widespread adoption of this technology is the high cost of the impedance measurement instrument as well as the complex algorithm required to employ image reconstruction. The majority of the readily available devices perform image reconstruction after the full measurement of the observation object causing the device not be able to provide imaging in real-time. This research is conducted to provide a simple and easily developed EIT system that is able to perform measurement and image reconstruction with low latency. This research is conducted through the process of designing and assembling an EIT system which utilizes Arduino using MATLAB software. The software portion of the system is integrated into MATLAB to eliminate latency due to data transfer between programs. EIDORS algorithm is used to perform image reconstruction. Impedance measurement within the system is conducted with 16 electrode using four-terminal sensing methods St 50 kHz The resulting EIT system is a simple system that integrate EIDORS-MATLAB with Arduino to perform image reconstruction."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Arbariyanto Mahmud Wicaksono
"Meningkatnya penggunaan pencitraan dalam bidang medis mendorong perkembangan metode dan modalitas baru yang aman, murah dan cepat. Electrical Impedance Tomography (EIT) merupakan salah satu pengembangan dalam pencitraan medis yang mampu memberikan pencitraan yang aman tanpa radiasi. Permasalahan utama dari sistem EIT adalah diperlukannya algoritma yang kompleks untuk melakukan pencitraan dengan hasil yang memiliki resolusi rendah. Penelitian diharapkan dapat menyediakan rangkaian EIT sederhana sehingga dapat dengan mudah digunakan dan dikembangkan. Penelitian dilakukan dengan cara merancang dan membangun sistem pencitraan EIT berbasis MATLAB dan Arduino yang kemudian diuji terhadap beragam skenario objek pengamatan.
Hasil pencitraan yang dihasilkan menunjukkan bahwa sistem mampu merepresentasikan berbagai variasi struktur dari objek pengamatan. Pengukuran impedansi pada sistem EIT dilakukan menggunakan metode two-point technique menggunakan 8 elektrode dan 16 elektrode pada frekuensi 50 kHz. Objek pengamatan utama pada pengujian sistem merupakan gelas acrylic yang diisi oleh air keran dengan nilai TDS (Total Dissolved Solids) sebesar 300 ppm. Sistem pencitraan EIT yang dirancang dan dibangun dapat melakukan pencitraan terhadap objek pengamatan menggunakan sistem yang sederhana.

The rise of imaging in medical field has boost the progress of new imaging method and modality that area safer, cheaper, and faster. Electrical Impedance Tomography (EIT) is one of such modality that provide safe medical imaging through non ionizing method. The downside of the EIT method is the complex algorithm needed to produce imaging result and low resolution. This study hope to provide a simple EIT imaging system that are easily used and developed. The proposed system designed in this study is a MATLAB and Arduino based imaging system which are then tested under several observation object scenario.
The imaging results that are produced by the system are able to represent the varying observational objects structure. Impedance measurement method that is implemented in the proposed system is a two-point technique using 8 electrode and 16 electrode with a frequency of 50 kHz. The main observation object of this system is an acrylic cup filled with tap water that has a TDS (Total Dissolved Solids) of 300 ppm. The resulting EIT imaging system is a simple system that are able to produce imaging results based on the observation object.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>