Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3976 dokumen yang sesuai dengan query
cover
UI-IJTECH 2:3 (2011)
Artikel Jurnal  Universitas Indonesia Library
cover
Normah Mohd-Ghazali, auhtor
"The Brundtland Report (also known as Our Common Future) has placed sustainability of energy resources and environmental degradation on a common global agenda. Increasing awareness has spurred much research into alternative clean energy technologies. Thermoacoustic cooling as an environmentally friendly refrigeration system is one of the research areas being pursued. Although not commercially available, successful systems have been completed. There are, however, still many fundamental issues related to the thermoacoustic effects and the associated heat transfer that must be addressed. This paper reports a portable counter-top thermoacoustic cooling apparatus designed and fabricated at the Universiti Teknologi Malaysia (UTM). Based on a standing wave resonator tube, the system with a pvc resonator tube of 60 mm diameter which was initially at 24o C, accomplished cooling effects under a minute, up to 18.5o C, without the use of chlrofluorocarbons (CFCs) or other similar refrigerants which have been known to be hazardaous to our living environment. Another acrylic 110 mm diameter tube once recorded 8o C with the ambient held at 23o C. The cooling in the first system was repeatable but not significant enough for practical applications. However, with no refrigerants used and its relatively simple manufacturing, a thermoacoustic cooling system is a potentially clean cooling system to be further investigated for practical or specific applications."
Depok: Faculty of Engineering, Universitas Indonesia, 2011
UI-IJTECH 2:3 (2011)
Artikel Jurnal  Universitas Indonesia Library
cover
Akhmad Syihan Santoso
"Penggunaan Organic Rankine Cycle (ORC) sebagai sumber energi listrik daerah terpencil menjadi salah satu solusi untuk Indonesia, dikarenakan ORC tidak membutuhkan sumber panas yang tinggi. ORC menggunakan refrigeran sebagai fluida kerja. Namun, penggunaan refrigeran halokarbon yang tinggi menyebabkan pemanasan global dan rusaknya lapisan ozone, yang ditandai dengan tingginya nilai Global Warming Potential (GWP) dan Ozone Depletion Potential (ODP) refrigeran halokarbon. Pengembangan refrigeran dilakukan dengan harapan dapat mengurangi efek yang ditimbulkan terhadap lingkungan. Salah satu solusinya adalah penggunaan refrigeran natural. Refrigeran natural memiliki nilai GWP dan ODP yang rendah sehingga tidak menambah efek negatif yang sudah ditimbulkan oleh refrigeran halokarbon. Refrigeran hidrokarbon merupakan salah satu jenis refrigeran natural. Penelitian ini ditujukan untuk mengetahui koefisien perpindahan kalor yang dimiliki, dan memahami faktor-faktor yang mempengaruhi nilai koefisien perpindahan kalor. Koefisien perpindahan kalor akan naik seiring dengan kenaikan dari Heat Flux.Sedangkan nilai koefisien perpindahan kalor akan bervariatif dalam kondisi mass flux rendah dan naik seiring kenaikan mass flux. Kualitas massa uap dan Temperatur saturasi menjadi faktor tambahan yang memiliki pengaruh beragam terhadap nilai koefisien perpindahan kalor.

Organic Rankine Cycle (ORC) is one of the solutions for Indonesia to solve electricity demands at the remote area, because ORC only require low heat source. The working fluid of ORC is refrigerant. However, the use of halocarbon refrigerant is causing global warming anda ozone depletion, that have high value of Global Warming Potential (GWP) and Ozone Depletion Potential (ODP) on the halocarbon refrigerant. The development of refrigerant has to be done to reduce the negative impact to the environment. One among of the solution is natural refrigerant. Natural refrigerant has the lowest number of GWP and ODP. Therefore, it does not add the negative effect caused by halocarbon refrigerant. Hydrocarbon refrigerant is one kind of natural refrigerant. This study aims to the value of heat transfer coefficient and comprehend the factors affecting the value of heat transfer coefficients. Heat transfer coefficient increase with an increase of heat flux. Meanwhile the value of heat transfer coefficients varies in low mass flux conditions and increase with rise of the mass flux. Vapor quality and saturation temperature becomes additional factors affecting to the value of heat transfer coefficient.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cheremisinoff, Nicholas P.
Ann Arbor, Mich.: Ann Arbor Science, 1981
621.197 CHE c
Buku Teks  Universitas Indonesia Library
cover
Andonyev, S.M.
Moscow: Mir, 1976
669.8 AND e
Buku Teks SO  Universitas Indonesia Library
cover
Misael Satrio
"ABSTRAK
Kebutuhan AC rumah di Indonesia yang tinggi disebabkan oleh suhu harian tinggi dan kelembaban udara tinggi, namun industri AC terancam isu pemanasan global setelah pelarangan R-22 di Indonesia. Hidrokarbon fraksi ringan yaitu propana, butana (isobutana dan n-butana), dan propilena berpotensi digunakan sebagai refrigeran pengganti R-22 pada AC rumah karena nilai GWP (potensi pemanasan global) yang sangat kecil. Campuran propana/n-butana, isobutana/n-butana, dan propilena/n-butana dianalisis dengan memvariasikan fraksi mol pada campuran. Simulasi siklus refrigerasi dengan REFPROP mendapatkan data tekanan berbanding entropi dan entalpi untuk mendapatkan laju alir massa refrigeran, kerja kompresor, dan COP. Perbandingan dengan kinerja R-22 dilakukan dengan kapasitas AC rumah sebesar 0,75 hp dan suhu ruangan 30oC. Campuran yang direkomendasikan adalah propilena/n-butana 0,95/0,05 dengan COP 5,56, laju alir massa refrigeran 1,964 g/s, dan kerja kompresor 100,424 W. Kerja kompresor dan COP hampir sama dengan R-22, tetapi massa refrigeran lebih rendah 53,22% dari R-22. Campuran isobutana/n-butana 0,95/0,05 tidak dipilih terlepas dari tingginya COP karena terbentuk liquid pada kompresor. Nilai GWP propilena/n-butana 0,95/0,05 adalah 1,91 atau 0,11% dari GWP R-22.

ABSTRACT
High demand of home air-conditioning system (AC) in Indonesia is triggered by high daily temperature and high humidity, but the demand is overshadowed by global warming issue after R-22 ban in Indonesia. Light hydrocarbons such as propane, butane (isobutane and n-butane), and propylene are potential to be used as R-22 replacement in air conditioning systems due to low global warming potential (GWP). Propane/n-butane, isobutane/n-butane, and propylene/n-butane are simulated to obtain refrigeration performance and GWP, by varying mole fraction. REFPROP simulation obtained enthalpy and entropy data from pressure variation that is used to find refrigerant mass flow rate, compressor work, and COP. Comparation to R-22 is done for 0.75 hp capacity AC and 30o"
2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fadhil Azharrisman
"Penelitian ini membahas mengenai perancangan dan perhitungan palka ikan untuk kapal ikan 30 GT menggunakan kapal yang dirancang khusus. Pada penelitian ini pendinginan palka ikan menggunakan sistem refrigerasi untuk mengoptimalkan volume ruangan palka karena, dalam pengoperasiannya palka berpendingin es membutuhkan 50% dari kapasitas ruang palka untuk memuat es. Dalam penelitian ini, dilakukan studi literatur guna menentukkan parameter perhitungan, desain geometrik palka, dan dilakukan simulasi CFD menggunakan Ansys Fluent untuk menilai bentuk aliran fluida pendingin dan waktu pendinginan produk, lalu dilanjutkan dengan perhitungan beban pendinginan dan kebutuhan daya listrik yang dibutuhkan untuk sistem pendingin yang telah dirancang. Berdasarkan hasil simulasi didapatkan waktu pendinginan paling cepat terjadi ketika kecepatan inlet fluida pendingin 8 m/s pada kapasitas pemuatan 100% dengan waktu pendinginan ikan dari 27°C sampai 0°C membutuhkan waktu selama 4 jam 15 menit, serta kebutuhan daya total untuk sisterm refrigerasi yaitu 5,88 kW.

This study discusses the design and calculation of fish hold for 30 GT fishing vessels using specially designed vessels. In this study, fish hold cooling uses a refrigeration system to optimize the volume of the hold because, in its operation, the ice-cooled hatch requires 50% of the capacity of the hold to load ice. In this study, a literature study was conducted to determine the calculation parameters, geometric design of the hold, and a CFD simulation was carried out using Ansys Fluent to review the shape of the cooling fluid flow and product cooling time then continued with the calculation of the cooling load and the electrical power required for the cooling system has been designed. Based on the simulation results, the fastest cooling time occurs when the cooling fluid inlet velocity is 8 m/s at a loading capacity of 100% with a cooling time of fish from 27°C to 0°C which takes 4 hours 15 minutes, as well as the total power requirement for the refrigeration system is 5.88 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Steinberg, Dave S.
New York : Wiley, 1980
621.381 STE c
Buku Teks  Universitas Indonesia Library
cover
Fajri Ashfi Rayhan
"Ice Slurry merupakan hasil rekayasa sistem pendingin pada evaporator dengan memanfaatkan air laut sebagai media freezing point depressing additive. Teknologi ice slurry sangat berperan penting dalam proses penangkapan ikan di laut lepas, karena kualitas ikan yang di dinginkan oleh ice slurry jauh lebih baik di bandingkan oleh media pendingin lainya. Hal tersebut disebabkan karena ikan didinginkan langsung oleh air laut yang suhu kristal es dapat mencapai dan seluruh badan ikan dapat terselubungi penuh dengan es. Penggunan propane sebagai media refrigerant dapat meningkatkan waktu terbentuknya ice slurry dan propane merupakan refrigerant yang ramah lingkungan.
Tujuan dari penelitian ini adalah untuk merancang prototipe ice slurry dan menganalisis perfroma sistem dengan membandingkan kualitas es antara penggunaan refrigerant R-22 dan propane. Parameter kualitas es pada penelitian ini adalah banyaknya es yang terbentuk terhadap lamanya waktu sistem bekerja dan ketahanan scraper dalam melakukan pengikisan es didalam evaporator. Sehingga semakin cepat ice slurry terbentuk dan scraper dapat terus beroperasi, maka semakin baik sistem rancangan. Variasi antara putaran scraper dan pompa merupakan variabel penentu kualitas es. Hasil dari penelitian ini menunjukan bahwa pembentukan ice slurry dengan refrigerant propane lebih baik dibandingkan R-22 yang ditinjau bedasarkan waktu penurunan suhu air laut, kestabilan tekanan kerja dan perfoma scraper.

Ice Slurry is engineered cooling system on the evaporator with the use of seawater as a medium freezing point depressing additive. Ice slurry technology plays an important role in the process of fishing on the high seas, because the quality of the fish is cooled by ice slurry is much better compared to other cooling media. This is because the fish is cooled directly by seawater temperature ice crystals can reach -10 ℃ and whole body fish can be enveloped filled with ice. The use of propane as a refrigerant media can also increase the time the formation of ice slurry and propane is an environmentally friendly refrigerant.
The Purpose of this research is to create a prototype of ice slurry and analyze perfrom of system by comparing the quality of the ice between the use of refrigerant R-22 and propane. Ice quality parameters in this study is the number of ice that forms on the length of time the system works and ablitity of scraper scorns of ice in evaporator. So the faster the ice slurry is formed and scraper can keep operated, the better the system design. Variations between rounds scraper and pump are variables determine the quality of the ice. The results of this study indicate that the formation of ice slurry with refrigerant propane better than R-22, which are reviewed by temperature of sea water, the stability of working pressure and performence of scraper.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63704
UI - Skripsi Membership  Universitas Indonesia Library
cover
Okti Giffari, auhtor
"Menara pendingin atau Cooling Tower merupakan salah satu komponen penting pada suatu pembangkit. Pada PLTP, menara pendingin berguna untuk menurunkan suhu fluida cair hasil dari perubahan fase gas-cair pada proses vakum di kondensor. Sehingga fluida cair dapat mebuang kalor panasnya ke udara luar dan dapat dipakai lagi untuk proses vakum pada kondensor. peningkatan vakum kondensor membuat hasil output listrik pada turbin semakin optimal. Oleh karena itu proses pendinginan fluida pada Menara Pendingin sangat penting. Akan tetapi proses pendinginan pada menara pendingin sangat bergantung dengan kondisi lingkungan udara lokasi pembangkit.
Pada skripsi ini penulis membuat analisis kinerja dari Menara Pendingin dengan jenis Crossflow inducted draft Cooling Tower dengan mengevaluasi hasil yang didapat dari data Control room dan data desain awal pembangkit. Dengan analisis kerja ini didapat bahwa temperatur wet bulb dari udara masuk cooling tower mempengaruhi nilai dari temperatur hasil pendinginan menara pendingin pada basin yang juga mempengaruhi kondisi tekanan vakum pada kondensor dan menyebabkan perubahan pada hasil beban generator.

Cooling tower is one of the important components of geothermal power plant. Cool-ing tower useful for lowering the temperature of liquid fluid result of the gas ?fluid changes phase in the proces of vacuum in condenser. So that the hot liquid fluid can transfer calorific heat to the outdoor air and the liquid result can be used again for the vacuum in the condenser. Condenser vacuum increase make the electrical out-put of the turbine further optimized. Therefore, the process of cooling fluid in the cooling tower is very important. But the cooling process in the cooling tower is very dependent on the environmental air plant site.
In this thesis, the author makes the analysis of the performance of the Crossflow inducted draft Cooling Tower to eval-uate the results obtained from the data Control room and plant the initial design data. The result found that the wet bulb temperature of the inlet air cooling tower affect the value of the temperature of cooling results in the cooling tower basin that also affect the condition of vacuum pressure in the condenser and cause changes in the results of the load generator
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64901
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>