Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 95031 dokumen yang sesuai dengan query
cover
Adilla Armando
"Daerah Cubadak terletak di Kabupaten Pasaman Barat, Provinsi Sumatera Barat. Ditinjau dari data geologi, daerah ini didominasi oleh batuan Sabak berumur Permo-Karbon dan berada pada zona depresi yang dipengaruhi oleh sesar-sesar normal sebagai akibat aktivitas tektonik. Daerah Cubadak diduga memiliki prospek panasbumi yang ditandai dengan kemunculan manifestasi permukaan berupa 3 mata air panas yang bertipe klorida-bikarbonat. Untuk mengkonfirmasi adanya potensi panasbumi tersebut, dilakukan survei metode Magnetotellurik (MT). Tahapan prosesing MT adalah sebagai berikut: seleksi data time-series, Transformasi Fourier, Robust Processing, Seleksi Cross Power, Static Shift Correction, dan kemudian inversi 2 dimensi dengan menggunakan model awal berupa sounding 1 dimensi. Hasil pengolahan data 2 dimensi kemudian diintegrasikan dengan data geologi, geokimia, metode gravitasi dan dijadikan acuan untuk mendapatkan suatu model konseptual dari sistem panasbumi Cubadak. Model konseptual tersebut menunjukkan bahwa lapisan reservoir panasbumi Cubadak berada di bawah lapisan alterasi and silifikasi permukaan. Batas atas zona reservoir diduga berada pada kedalaman 2000 m. Kisaran temperatur reservoir didapat dari data geotermometrik yaitu sebesar 148-161°C sehingga sistem panasbumi Cubadak termasuk kedalam moderate temperature geothermal system. Estimasi luasan area reservoir berdasarkan data MT adalah 8 km2. Berdasarkan kalkulasi, sumber panasbumi Cubadak memiliki potensi sekitar 28 MWe.

Cubadak area is located in West Pasaman, West Sumatra province. Based on the geological data, the area is dominated by Permo-Carbon Sabak formation and located in depression zone that influenced by normal faults. Cubadak area is estimated have the geothermal prospect due to presence of surface manifestations. There are three chloride-bicarbonate hot springs types. To confirm the geothermal potential, magneto telluric ( MT ) method was then carried out. MT Processing includes: time-series data selection, Fourier transform, Robust Processing, Cross Power Selection, Static Shift Correction, then two-dimensional inversion was conducted initial model as resulted from one-dimensional inversion. The result was then integrated with geological, geochemical, and gravity data. The conceptual model shows that geothermal reservoir zone is located under alteration layer and surface silification. The depth of the reservoir top zone is estimated to be 1000-1500 m. Reservoir temperature is estimated using a geothermometry is about 148-161 ° C. Accordingly, the Cubadak geothermal system is clasified into the moderate temperature system. The reservoir area is estimated from MT data is about 8 km2. Based on calculation, Potential of Cubadak geothermal resources is about 28 MWe.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S54432
UI - Skripsi Membership  Universitas Indonesia Library
cover
Munazyi
"Wayang windu merupakan sistem panasbumi yang terletak di daerah Pengalengan, 35 km di selatan Kota Bandung. Sistem panasbumi yang berada di Bandung Volcanic Complex ini merupakan salah satu sistem panasbumi dengan temperatur dan entalpi yang tinggi. Model sistem panasbumi ini tergolong unik karena merupakan transisi dari sistem dominasi uap dan sistem dominasi air. Keberhasilan dalam eksplorasi maupun dalam proses pengembangan sistem panasbumi ini salah satunya ditentukan oleh keberhasilan mengidentifikasi struktur. Microearthquake (MEQ) merupakan metode yang cukup efektif untuk mendeteksi struktur dengan cara mendengarkan renspon alamiah dari perubahan stress dan strain dari batuan dalam bentuk gempa mikro. Waktu tiba gelombang P dan S serta identitas sinyal dilakukan penghitungan untuk mendapatkan hiposenter dengan menggunakan Hypo71. Model kecepatan yang digunakan adalah satu dimensi yang homogen dengan rasio Vp terhadap Vs adalah 1.79. Kemudian, relokasi hiposenter dilakukan dengan algoritma Double Difference dengan fase gelombang P meliputi data katalog dan data pasangan event yang memiliki similaritas yang tinggi berdasarkan hasil korelasi silang. Setelah melakukan relokasi dengan HypoDD, didapatkan distribusi hiposenter yang cukup logis dari bentuknya yang memiliki ekstensi horisontal dan vertikal serta memiliki RMS yang minimal. Kemudian, distribusi hiposenter hasil relokasi divisualisasikan dengan GeoSlicer-X untuk kemudian dilakukan konfirmasi dengan data struktur geologi dan data Magnetotellurik untuk menguji validitas dari distribusi hiposenter yang berhasil dihitung. Hasilnya, distribusi hiposenter berada pada batas antara heatsource dan reservoir yang juga memiliki kesesuaian terhadap struktur di permukaan. Interpretasi kaitan MEQ dengan aktivitas injeksi menghasilkan prediksi persebaran fluida ke arah timur dan selatan berdasarkan proyeksi vertikal dari distribusi hiposenter.

Wayang Windu Geothermal System lies at Pangalengan, 35 kilometers South of Bandung. The Geothermal System that located in Bandung Volcanic Complex has high temperature and high enthalpy. This is very unique geothermal system because it is the transition of vapor dominated and liquid dominated system. To make the exploration success for, the main factor is determined to structure identification. Microearthquake (MEQ) is efficient method to detect the structure by sensing every change of natural response in form earthquake that less than 3 richter scale. First arrivals time and characteristics of signal are calculated to get the hypocenter using Hypo71 (Geiger Algorithm). This calculation uses velocity model with homogeny seven layers with ratio Vp/Vs is 1.79. After that, the Double Difference algorithm with P phase is used to relocate the hypocenter using catalog data and high similarities of event pair determined by cross correlation. After relocating hypocenter using HypoDD, hypocenters distribution becomes more plausible because of the shape that has vertical and horizontal extension with minimum RMS residual. Then, the hypocenters are visualized using GeoSlicer-X to be confirmed and checked by geological structure and magnetotelluric data. The result shows that hypocenters not only lie at boundaries of low and high resistivity (heatsource) but also firmed with the geological structure orientation. Interpretation of MEQ and fluid injection activities shows fluid flow prediction that head for southern and eastern of injection well.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S54032
UI - Skripsi Membership  Universitas Indonesia Library
cover
Haryo Gusmedi Sudarmo
"Telah dilakukan penelitian guna mendelineasi sistem panas bumi lapangan geothermal ldquo;H rdquo;. Penelitian ini menggunakan metode remote sensing untuk memetakan struktur dan alterasi di permukaan. Analisis geokimia digunakan untuk mengetahui karakteristik sistem panas bumi dan analisis geofisika digunakan untuk memetakan kondisi sistem panas bumi di bawah permukaan. Berdasarkan analisis remote sensing dengan teknik band combination secara pengamatan manual menunjukkan bahwa arah utama dari kelurusan - kelurusan yang berkembang di daerah penelitian ldquo;H rdquo; adalah Barat Laut - Tenggara dan Barat Daya - Timur Laut sesuai dengan Peta Geologi Regional yang berkorelasi dengan kemunculan beberapa manifestasi. Analisis remote sensing juga menemukan 1 lokasi yang diduga merupakan alterasi di permukaan. Analisis data geokimia dilakukan terhadap 12 manifestasi menunjukkan bahwa mata air panas SL-1, SL-2, SLM-1, SLM-2, HTS-1, HTS-2, HTS-3, TBK, TLH-1, TLH -2, TLH-3 dan TLH- 4 merupakan manifestasi tipe outflow.
Berdasarkan diagram segitiga ternary Na - K - Mg, diagram Na-K/Mg-Ca, diagram Enthalpy - Chloride Mixing Model, geothermometer Na/K menunjukkan temperatur reservoar adalah sekitar 210 C - 240 C dan dapat dikategorikan ke dalam sistem geothermal moderate to high temperature. Analisis Inversi 3-D Data MT menggunakan 66 data titik ukur. Berdasarkan inversi 3-D Data MT diketahui bahwa lapisan clay cap dengan nilai resistivitas rendah le; 10 ?m tersebar di Selatan dengan ketebalan 500 meter hingga 1000 meter. Lapisan reservoar terletak di bawah clay cap dengan nilai resistivitas >10 - 65 ?m. Base of Conductor BOC diperkirakan berada pada kedalaman 700 meter dengan updome berada di antara Sesar Wairutung dan Sesar Banda. Berdasarkan peta BOC diperoleh luas area prospek geothermal sekitar 16.5 km2.

The study of ldquo H rdquo geothermal field has been conducted to delineate their geothermal system. This study uses remote sensing method for mapping structure and alteration on the surface. Geochemical analysis is used to determine the characteristics of geothermal system and geophysical analysis is used to interpret the condition of geothermal system of sub surface. Based on remote sensing analysis using band combination technique with manual observation indicates that the main direction of the developed lineaments in the research area H is Northwest Southeast and Southwest Northeast in accordance with Regional Geological Map correlated with the appearance of several manifestations. The remote sensing analysis also found 1 suspected alteration site on the surface. Analysis of geochemical data was performed on 12 manifestations shows that hot springs SL 1, SL 2, SLM 1, SLM 2, HTS 1, HTS 2, HTS 3, TBK, TLH 1, TLH 2, TLH 3 and TLH 4 are outflow manifestations type.
Based on the diagram of the ternary triangle Na K Mg, Na K Mg Ca diagram, Enthalpy Chloride Mixing Model diagram, Na K geothermometer estimates the reservoir temperature is about 210 C 240 C and can be categorized into the moderate to high temperature geothermal system. Analysis of inversion 3 D MT data using 66 data points measurement. Based on 3 D inversion MT data is known that clay cap layer with low resistivity value le 10 m spread in South with thickness 500 meter to 1000 meter. The reservoir layer is located under clay cap with resistivity value 10 m 65 m. Base of Conductor BOC is estimated to be at depth of 700 meters with an updome located around Wairutung Fault Banda Fault. Based on BOC, the prospectable area of geothermal system is about 16.5 km2.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T48035
UI - Tesis Membership  Universitas Indonesia Library
cover
Solehudin
"Dalam beberapa dekade, akuisisi MT biasanya dilakukan dalam bentuk profil lintasan 2D. Namun pemodelan inversi 2D memiliki kekurangan terutama terkait dengan keberadaan struktur yang lebih kompleks 3D strike . Ambiguitas ini termasuk dalam pemilihan mode yang digunakan TE atau TM . Ambiguitas ini dapat menyebabkan kesalahan dalam interpretasi. Ambiguitas data seperti yang terjadi pada inversi 2D dapat diatasi dengan menggunakan program inversi 3D.Inversi MT 3D dilakukan dengan menggunakan dengan menggunakan perangkat lunak Mod3DEM dengan algoritma NLCG Non Linear Conjugate Gradient dan sudah memasukkan faktor topografi. Data input yang digunakan dalam inversi 3D adalah sebanyak 92 titik, dengan range frekuensi 320 ndash; 0.01 Hz. Pengolahan data menggunakan rotasi principal axis dan koreksi statik menggunakan data TDEM. Selain itu, data pendukung lain yang digunakan dalam penelitian ini adalah data geokimia dan data geologi.
Berdasarkan hasil inversi 3D MT, Karakteristik sistem geothermal lapangan ldquo;INARA rdquo; terlihat dengan batuan penudung memiliki resestivitas rendah 80 ohm-m. Top of reservoir berada di ketinggian 500 meter dari MSL dengan heat source berada di bawah puncak gunung WL. Dari hasil perhitungan geothermometer silika dan diagram entalphy-Cloride mixing, diperoleh temperatur reservoir daerah prospek panas bumi ldquo;INARA rdquo; adalah 200 oC. Sedangkan berdasarkan geothermometer CO2, temperatur reservoir daerah prospek panas bumi ldquo;INARA rdquo; adalah 260 oC dan masuk dalam kategori high temperature >225 oC.

Within a few decades, MT acquisition is used to be done in a 2D track profile. However 2D inversion modeling has its drawbacks mainly related to the existence of the existence of complex structures 3D strike . This will bring ambiguity that can lead to errors in interpretation. Data ambiguity as occurs in 2D inversion can be overcome by using 3D inversion program.The software used in MT 3D Inversion is Mod3DEM with NLCG Non Linear Conjugate Gradient algorithm and has included topography factor. The input data used in 3D inversion is 92 points, with frequency range 320 0.01 Hz. The data processing used principal axis rotation and static corrected by TDEM data. The other supporting data used in this study are geochemical data and geological data.
Based on the 3D MT inversion results, the characteristics of the INARA geothermal field system are seen with low residence rocks 80 ohm m. Top of the reservoir is at an altitude of 500 meters from MSL with the heat source is under the peak of WL mountain. From the calculation of silica geothermometer and entalphy cloride mixing diagram, it is known the reservoir temperature of geothermal prospect region INARA is 200 oC. While based on CO2 geothermometer, the reservoir temperature of geothermal prospect region INARA is 260 oC and included in high temperature 225 oC.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T48702
UI - Tesis Membership  Universitas Indonesia Library
cover
Eka Yunita
"Daerah penelitian “M” merupakan salah satu daerah yang memiliki potensi geotermal di Indonesia. Hal tersebut ditunjukkan dengan adanya struktur geologi dan kemunculan manifestasi di permukaan yang dapat membantu dalam mengidentifikasi keberadaan sistem geotermal di bawah permukaan. Penelitian ini menggunakan inversi 3-dimensi magnetotellurik untuk mengetahui distribusi resistivitas di bawah permukaan, penentuan area prospek, serta pembuatan model konseptual dengan integrasi data magnetotellurik dan data pendukung berupa data geologi, geokimia, dan gravitasi. Berdasarkan data pendukung geologi, daerah “M” terdiri dari susunan produk vulkanik berumur kuarter dan struktur geologi dengan arah barat laut-tenggara. Dari data pendukung geokimia, ditemukan endapan travertine di sekitar manifestasi mata air panas yang relatif bersifat netral, temperatur cukup tinggi, dan berasosiasi dengan struktur geologi. Fluida di mata air panas tersebut dominan bertipe bicarbonate water yang menandakan fluida berasal dari reservoir dan dominan telah terkontaminasi oleh meteoric water. Fluida tersebut juga dominan memiliki nilai klorida tinggi yang menandakan bahwa lingkungan manifestasi mata air panas berada di lingkungan vulkanik. Selain itu, perhitungan dengan geotermometer diperoleh dugaan temperatur reservoir berkisar antara 160°C-180°C. Berdasarkan hasil pemodelan inversi 3-dimensi magnetotellurik dan data pendukung berupa model forward2-dimensi gravitasi diketahui sebaran dari variasi resistivitas dan densitas bawah permukaan yang menggambarkan lapisan clay cap, top of reservoir, dan bentuk updome yang kemungkinan merupakan heat source. Lapisan dengan nilai resistivitas rendah diduga merupakan clay cap atau batuan penudung berupa sebaran batuan beku yang mengalami alterasi. Di bawah lapisan clay cap terdapat sebaran resistivitas medium yang diindikasikan sebagai reservoir berupa batu gamping bahbotala. Di bagian bawahnya terdapat lapisan dengan resistivitas tinggi yang kemungkinan adalah batuan metamorf yang menjadi batuan dasar/basement. Diantara basement ini terdapat bentuk updome dengan resistivitas sedikit lebih tinggi yang diduga merupakan batuan terobosan atau intrusi yang dapat menjadi sumber panas bagi sistem geotermal. Sumber panas ini diduga berasal dari Dolok Tinggi Raja dikarenakan terbentuknya dome di permukaan yang mungkin diakibatkan oleh adanya larutan magma yang tidak tererupsikan keluar permukaan sehingga membentuk batuan terobosan di bawah permukaan. Adanya sumber panas ini dapat menimbulkan aliran fluida panas secara vertikal (upflow). Berdasarkan integrasi data-data tersebut, area prospek geotermal di daerah “M” diperkirakan berada di sekitar Dolok Tinggi Raja melebar ke arah timur laut, timur, dan selatan.

The research area "M" is one of the areas with geothermal potential in Indonesia. This is indicated by the presence of geological structures and the appearance of manifestations on the surface which can assist in identifying the presence of subsurface geothermal systems. This study uses 3-dimensional magnetotelluric inversion to determine the distribution of resistivity below the surface, determine prospect areas, and construct a conceptual model by integrating magnetotelluric data and supporting data in the form of geological, geochemical and gravity data. Based on supporting geological data, the "M" area consists of volcanic products of quarter age and geological structures in a northwest-southeast direction. From supporting geochemical data, travertine deposits around hot spring manifestations were found which were relatively neutral, had relatively high temperatures, and were associated with geological structures. The fluid in the hot springs is dominant of the bicarbonate water type, which indicates that the fluid comes from a reservoir and has been predominantly contaminated by meteoric water. The fluid also dominantly has a high chloride value which indicates that the manifestation environment of the hot springs is in a volcanic environment. In addition, calculations with the geothermometer obtained an estimated reservoir temperature ranging from 160°C-180°C. Based on the results of 3-dimensional magnetotelluric inversion modeling and supporting data in the form of a 2-dimensional forward gravity model, it is known that the distribution of resistivity and subsurface density variations describes the clay cap layer, top of reservoir, and up-dome shape which may be a heat source. The layer with a low resistivity value is thought to be a clay cap or a cap rock in the form of a distribution of altered igneous rocks. Beneath the clay cap layer, there is a medium resistivity distribution which is indicated as a reservoir in the form of bahbotala limestone. At the bottom, there is a layer with high resistivity which is probably the metamorphic rock that became the basement. Among these basements, there is an up-dome with slightly higher resistivity which is thought to be a breakthrough or intrusive rock which can be a heat source for geothermal systems. This heat source is thought to have originated from Dolok Tinggi Raja due to the formation of a dome on the surface which may be caused by the presence of magma solution that has not erupted off the surface to form breakthrough rock below the surface. The existence of this heat source can cause a vertical flow of hot fluid (up-flow). Based on the integration of these data, the geothermal prospect area in the “M” area is estimated to be around Dolok Tinggi Raja, widening to the northeast, east, and south."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Wahyu Noor Ichwan
"ABSTRAK
Inversi data magnetotellurik merupakan suatu proses mengubah data magnetotellurik menjadi penampang resistivitas. Salah satu metode inversi yang digunakan adalah inversi 3D. Inversi 3D magnetotellurik mengasumsikan bahwa bumi memiliki variasi resistivitas baik arah vertikal maupun lateral. Inversi tersebut menghasilkan model yang paling mendekati keadaan lapisan bumi yang sebenarnya. Akan tetapi, inversi 3D dimensi membutuhkan memori serta waktu yang lama dalam prosesnya. Untuk mengatasi masalah tersebut, digunakan variasi model awal sebagai pengontrol proses inversi. Model awal yang dapat digunakan adalah resistivitas hasil inversi 1D dimana hasil inversi tersebut memiliki kemiripan dengan hasil inversi 3D. Pada penelitian ini, penulis melakukan inversi data riil magnetotellurik dengan memvariasikan beberapa model awal. Variasi 'inversi dengan menggunakan model awal 1D menunjukkan bahwa model awal 1D mampu mengontrol proses inversi 3D dilihat dari kesesuaian hasil inversi 3D dengan model awal yang digunakan. Selain itu, hasil inversi dengan menggunakan model awal data inversi 1D menunjukkan hasil yang lebih baik pada model yang menggunakan lebih banyak mesh grid. Hal tersebut dapat dilihat dari RMS error model terhadap data observasi.

ABSTRACT
Inversion of Magnetotelluric data is a process to obtain resistivity variation from magnetotelluric data. 3D Inversion of magnetotelluric data is a method that usually used. Those method assume that earth has resistivity variation along vertical and lateral direction. It can produce the most similliar earth resistivity model to the real earth. However, 3D inversion method need high amount of CPU memory and calculation time. In order to cover that weakness, initial model is used to control the inversion process. The initial model used is resistivity variation from 1D inversion of magnetotelluric data. Resistivity variation of 1D inversion has simmiliar pattern with resistivity variation of 3D inversion. 3D inversion is done on real magnetotelluric data with variation of initial model. The variabels which are used initial model are resistivity variation and number of mesh grid blocks. The results of 3D inversion using 1D resistivity initial model show that initial model can control the inversion process. The result of 3D inversion have similiar pattern with the inisial model which is used. The results of 3D inversion using 1D resistivity initial model show better result than 3D inversion using homogenous resistivity initial model on larger number of mesh grid, it can be proven by its RMS errors."
2015
S58259
UI - Skripsi Membership  Universitas Indonesia Library
cover
Taihitu, Paulus Jirre Hacika
"Aktivitas geotermal pada daerah X telah ditemukan melalui keberadaan manifestasi panas bumi yang sangat impresif di beberapa titik. Beberapa penelitian yang dilakukan di daerah ini bertujuan untuk menemukan lokasi dan karakteristik reservoir utama sistem geotermal yang ada di area prospek. Namun, beberapa hasil interpretasi yang ditemukan ambigu dikarenakan penggunaan metode survei yang tidak tepat. Dalam penelitian ini, model konseptual yang terintegrasi dari metode magnetotellurik, geokimia, dan geologi digunakan untuk mendelineasi zona reservoir, karakteristik fluida reservoir, dan temperatur reservoir. Berdasarkan hasil konstruksi model konseptual, reservoir sistem geotermal di daerah penelitian ini ditemukan menggunakan metode magnetotellurik berada tepat di bawah tubuh gunung A. Keberadaan manifestasi fumarol di puncak gunung A, tepatnya di kawah gunung A yang mengalami perluasan ke arah timur laut dan sebagian ke arah barat laut, memvalidasi hasil ini. Temperatur pada reservoir mencapai 310°C, dengan sumber panas yang berasal dari gunung A muda. Area prospek diperkirakan sekitar 24 km dengan top of reservoir pada elevasi 1000 meter. Berdasarkan hasil ini, pengeboran eksplorasi dengan tipe sumur standard hole direkomendasikan untuk memvalidasi hasil eksplorasi 3G (geofisika, geokimia, geologi), yang akan ditajak pada kedalaman 2000 meter.

Geothermal activity in area X has been identified through the presence of impressive manifestations of geothermal activity at several points. Several studies conducted in this area aimed to locate and characterize the main reservoir of the geothermal system present in the prospect area. However, some of the interpreted results were ambiguous due to the improper use of survey methods. In this study, a conceptual model integrated from magnetotelluric, geochemical, and geological methods was used to delineate the reservoir zone, fluid reservoir characteristics, and reservoir temperature. Based on the constructed conceptual model, the geothermal reservoir system in this study area was found to be located precisely beneath the base of Mount A using the magnetotelluric method. The presence of fumaroles at the summit of Mount A, specifically in the Kawah Mount A, which is expanding towards the east-northeast and west-northwest, validates these results. The reservoir temperature reaches 310°C, with the heat source originating from the young Mount A. The prospect area is estimated to be approximately 24 km with a top of reservoir at an elevation of 1000 meters. Based on these results, drilling exporation with a standard hole type is recommended to validate the 3G exploration results (geophysics, geochemistry, geology), which will be drilled to a depth of 2000 meters."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fitriyani Mustika Ruslita
"Energi panas bumi adalah energi terbarukan yang sedang dikembangkan di dunia ini. Namun sebelum energi panas bumi dapat dimanfaatkan, perlu dilakukan eksplorasi untuk mengetahui kondisi bawah permukaan. Ada tiga hal yang harus dipenuhi dalam menentukan target eksplorasi sistem panas bumi, yaitu adanya suhu bawah permukaan yang tinggi, fluida dengan derajat keasaman netral, dan adanya zona dengan permeabilitas tinggi. Zona dengan permeabilitas tinggi berkaitan dengan adanya struktur geologi bawah permukaan atau patahan. Metode Magnetotellurik (MT) dan Metode Microearthquake dapat digunakan untuk mendelineasi keberadaan struktur bawah permukaan. Data MT riil diolah dengan metode inversi 3-D sampai akhirnya didapatkan karakteristik dari diagram polar, induction arrow, dan penampang resistivitas. Diagram polar dapat mengidentifikasi adanya patahan, sedangkan induction arrow dapat mengidentifikasi zona konduktif yang biasanya mengindikasikan struktur bawah permukaan. Hasil ini didukung oleh data MEQ riil yang telah diolah dengan menggunakan metode single station sampai didapatkan lokasi hiposenter yang menandakan zona dengan permeabilitas tinggi. Data geologi dan geokimia yang dikombinasikan dengan hasil dari pengolahan data riil MT dan MEQ tersebut menghasilkan delineasi daerah dengan suhu yang tinggi, memiliki fluida dengan derajat keasaman netral, serta zona dengan permeabilitas tinggi dan memiliki struktur bawah permukaan yang nantinya akan dijadikan target pengeboran.

Geothermal energy is a renewable energy which is now being developed all over ther world. However, before it can be optimized, exploration needed to be done in order to understand about the subsurface condition. There are three things that needed to be fulfilled in order to define the exploration target of geothermal system : high subsurface temperature, neutral fluids, and a zone with high permeability. High permeability zones are often associated with subsurface geological structure or fault. Magnetotelluric (MT) dan Microearthquake (MEQ) methods can be utilized to delineate subsurface structures. Polar diagram, induction arrow, and resistivity section are obtained from 3-D inversion of a real MT data. Polar diagram can identify the existence of a fault, meanwhile induction arrow can only identify conductive zones. These results will be supported with high permeability zone and hipocenters of real MEQ data which has been processed by single station method. Geology and geochemistry data can be combined with MT and MEQ results, thus the high subsurface zone, neutral subsurface fluids, high permeability zone and subsurface structure can be delineated, also well target location can be obtained."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Syafrima Wahyu
"Telah dilakukan penelitian guna delineasi zona prospek sistem panasbumi daerah ldquo;Z rdquo; menggunakan permodelan tiga Dimensi magnrtotellurik didukung data terpadu berupa geologi dan geokimia serta terintegrasi data gravitasi. Daerah panasbumi ldquo;Z rdquo; dalam tatanan tektoniknya termasuk pada jalur backarc Sumatera, tepat pada salah satu segmen sesar Sumatera bagian selatan, disusun oleh batuan vulkanik dan sedimen klastik yang berumur Tersier hingga Kuarter Andesit-Basalt . Gejala adanya sistem panasbumi pada daerah penelitian ditandai dengan kemunculan manifestasi permukaan berupa alterasi dan lima mata air panas bersuhu 44,4 - 92,5 oC, pH 8,19 - 9,43 dan bertipe bikarbonat, sulfat-bikarbonat, serta sulfat-klorida. Pembentukan sistem panasbumi dipengaruhi oleh aktivitas tektonik menyerong oblique antara lempeng Samudera India dan Lempeng Kontinen Eurasia searah dengan pola sesar Sumatera.
Berdasarkan analisis air panasbumi temperatur reservoir diambil melalui perhitungan geothermomether SiO2 Fournier 1977 , Na-K Giggenbach 1988 , Na-K-Ca, diagram Na-K-Mg serta diagram Enthalphy - Cloride Mixing Model berkisar 145 - 155oC, termasuk dalam sistem panas bumi bertemperatur sedang. Berdasarkan inversi tiga dimensi data MT didapatkan kedalaman Top of Reservoar TOR sistem panasbumi daerah ldquo;Z rdquo; sekitar 400 m elevasi 50 mdpl sedangkan berdasarkan forward modeling data gravitasi lintasan 2 dimensi diperkirakan sumber panas berupa cooling instrusion diperkirakan batuan gabro ; resistivitas ge; 450 ?m ; densitas 2,95 - 3,15 gr/cc dan reservoar berupa batupasir resistivitas 50 - 250 ?m ; densitas 2,60 gr/cc . Sistem panasbumi daerah penelitian termasuk jenis tektonik fracture zone dengan temperatur sedang dengan luas daerah prospek sekitar 7,5 km2.

A study for delineating geothermal system of prospect area ldquo Z rdquo has been done by using tree dimension modeling of magnetotelluric supported unified data just like geological and goechemical and integrated gravity data. Geothermal area ldquo Z rdquo in tectonic setting included in Sumatra volcanic backarc, right on one of the southern part of Sumatra fault segment. Compodes by volcanic and clastic sendimentary rock are Tertiary to Quarternary Andesite Basalt. The existance of goethermal system in this area is indicated by the presence of thermal manifestation in form of alteration and five hot springs temperature in the ranges 44.4 ndash 92.5 oC, and pH 8.19 ndash 9.43 and type of fluida are bicarbonate, sulphate bicarbonate, and sulfate chloride. The development of geothermal system is affected by tectonic oblique between the Indian Ocean plate and the Eurasian Contenent Plate direction of the Sumatra fault patterns.
Based on the analysis of geothermal water reservoir temperature are taken through the calculation geothermometer SiO2 Fournier 1977, Na K Giggenbach 1988 , Na K Ca, Na K Mg diagram and Enthalpi Mixing Cloride Model range 145 ndash 155 oC, classified as intermediate temperature. Base on a three dimensional inversion of the magnetotelluric data obtained depth Top of Reservoir TOR geothermal system area ldquo Z rdquo about 400 m elevation 50 meters above sea leavel , while based on the two dimensional of the gravity data predicted heat sources such as cooling instrusion estimated gabbro density 2,95 ndash 3,15 gr cc and reservoar such as sandstone resistivity 50 ndash 250 m density 2,60 gr cc . The Geothermal systems of research area classified as the type of intermediate temperature tectonic fracture zone with prospect area about 7,5 km2.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T46881
UI - Tesis Membership  Universitas Indonesia Library
cover
Okky Rizki Rohayat
"Dalam studi ini, penerapan metode analisis diagram polar impedansi dan splitting curve data magnetotellurik (MT) Lapangan Panas Bumi Wayang Windu bagian selatan adalah untuk mendeteksi struktur geologi bawah permukaan dan juga untuk mengetahui apakah metode ini dapat diterapkan pada area tersebut. Analisis ini dilakukan dengan membuat pemodelan forward terlebih dahulu sebagai acuan.
Hasil dari pemodelan forward menunjukkan bahwa adanya perbedaan resistivitas dua batuan atau lebih yang mengalami kontak akan menyebabkan split pada kurva MT dan distorsi pada bentuk diagram polar impedasi yang membentuk elongasi sejajar atau tegak lurus terhadap struktur (garis kontak). Struktur ini dikomparasi dengan data geologi, data hiposenter microearthquake, dan data sumur.
Hasil komparasi menunjukkan bahwa terdapat empat struktur hasil interpretasi data MT yang memiliki kecocokkan dengan struktur geologi dari data geologi dan sumur, dan beberapa struktur tidak memiliki kecocokkan atau hanya merupakan resistivity structure. Di sisi lain, metode ini dapat memprediksi arah dominan struktur geologi pada area penelitian.

In this study, application of the impedance polar diagram and splitting curve analysis method on magnetotelluric (MT) data of southern Wayang Windu geothermal field are to detect subsurface geological structure and also to find out whether this method can be applied to this area. This analysis is done by making forward modelling as a reference.
The result of forward modelling shows that the difference in resistivity of two or more rocks in contact will cause a split on the MT curve and distortion in the shape of the impedance polar diagram forming parallel or perpendicular elongation to the structure (contact line). This structures are compared with geological data, microearthquake hypocenter data, and well data.
The comparation results show that four structures of MT data interpretation results have correlation with the geological structure of the geological and well data, and some structures do not have correlation or merely resistivity structures. On the other hand, this method can predict the dominant direction of geological structure in the research area.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T45112
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>