Ditemukan 7429 dokumen yang sesuai dengan query
New York: Foster Wheeler Corporation, 1957
621.4 HEA
Buku Teks SO Universitas Indonesia Library
Cao, Eduardo
New York: McGraw-Hill, 2010
660 CAO h
Buku Teks SO Universitas Indonesia Library
Kinsky, Roger
New York : McGraw-Hill, 1977
621.402 KIN a
Buku Teks SO Universitas Indonesia Library
Soo, S. L
Tokyo: Maruzen Company Ltd, 1959
621.402 2 SOO t
Buku Teks SO Universitas Indonesia Library
Taborek, J
New York: McGraw-Hill, 1983
621.402 5 TAB h
Buku Teks SO Universitas Indonesia Library
Bockh, Peter von
"The book provides an easy way to understand the fundamentals of heat transfer. The reader will acquire the ability to design and analyze heat exchangers. Without extensive derivation of the fundamentals, the latest correlations for heat transfer coefficients and their application are discussed. The following topics are presented, steady state and transient heat conduction, free and forced convection, finned surfaces, condensation and boiling, radiation, heat exchanger design, problem-solving. After introducing the basic terminology, the reader is made familiar with the different mechanisms of heat transfer. Their practical application is demonstrated in examples, which are available in the Internet as MathCad files for further use. Tables of material properties and formulas for their use in programs are included in the appendix. "
Berlin: [, Springer], 2012
e20418180
eBooks Universitas Indonesia Library
Duago Pijar Wicaksono
"Heat engine thermoacoustic mengkonversi panas menjadi daya akustik tanpa adanya komponen yang bergerak. Untuk mengembangkan lebih jauh performa dari termoakustik jenis ini, maka diperlukan karakterisasi dari parameter-parameter yang bekerja. Pada pengujian kali ini dilakukan karakterisasi termoakustik berdasarkan posisi stack dan onset temperature dengan tujuan untuk mengetahui posisi stack dan besaran nilai onset temperature yang optimal. Variasi yang dilakukan pada pengujian ini untuk posisi stack yaitu pada posisi 20, 30, 40, 50, 60, 70, 80, 90, dan 100 mm dari ujung tabung tertutup, sedangkan untuk variasi onset temperatur dilakukan pada suhu awal termoakustik mulai bekerja (terendah 3950C) sampai 5000C. Pengujian ini dilakukan dengan menggunakan stack yang terbuat dari bahan dasar keramik dan menggunakan pemanas berbentuk nozzle serta panjang resonator 200 mm. Kecenderungan daya akustik yang dihasilkan mempunyai kemiripan dengan persamaan yang diusulkan oleh Swift et al [1], dengan daya terbesar yang dihasilkan terjadi pada saat posisi stack 50 mm dari ujung tabung tertutup dan onset temperature 5000C sebesar 9,81x10-4 Watt
Heat engine thermoacoustic converts heat into acoustic power with no moving parts. In order to improve the performance of the heat engine termoacoustic, working parameters should be optimized. In this examination, the thermoacoustic is characterized based on stack position and onset temperature in order to acknowledge the optimal value from both parameters. Stack position varieties chosen for this examination are 20, 30, 40, 50, 60, 70, 80, 90 and 100 mm from close-end tube, and onset temperature varieties chosen start from the lowest temperature that the engine regarded to be working (lowest 4100C) to 5000C. This examination uses nozzle shaped heater, ceramic stack, and 200 mm glass resonator. This experimental results indentified follows the equation proposed by Swift et al [1,] which have the largest value of acoustic power (9,81x10-4 Watts) where the stack placed 50 mm from close-end tube and the onset temperature regulated for 5000C."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S-pdf
UI - Skripsi Membership Universitas Indonesia Library
Abbyyu Prakeysya Wijaksono
"Central gathering station 10 (CGS-10) menampung seluruh fluida dari beberapa sumur minyak. Incoming fluida di area CGS-10 saat ini sebesar 212.000 BOPD. Pada tahun 2030 akan dilakukan peningkatan produksi sebesar 312.000 BOPD. Beberapa skenario yang dilakukan menghasilkan kesimpulan performa heat exchanger sudah tidak normal karena temperature outlet maksimum fluida pada berbagai kondisi tidak mencapai 175°F. Setelah dilakukan penilaian kecukupan kapasitas pada fasilitas yang ada, perlu adanya penambahan heat exchanger. Pada praktik keinsinyuran ini, analisis mechanical design dilakukan berdasarkan datasheet proces dan penjadwalan proyek berdasarkan analisis material take off (MTO) pada pekerjaan konstruksi civil & piping, dibantu dengan software Microsoft Project yang mempermudah dalam pembuatan engineering, procurement & construction (EPC Schedule). Dari Praktik keinsinyuran ini didapatkan material Tubes SA 213 TP316L ; Tubesheet, Baffles/Tube Support & Floating Head Cover SA 240-316L ; Tie Rods & Spacers SS 316L ; Bolt & Nut SA-193-B7 & SA-194- 2H ; Shell & Shell Cover SA 516 Gr.70 ; Shell Flange SA 105 ; Channel/Bonnet, Channel Cover & Channel Flange SA 105 + SA 240-316L Clad. Jalur kritis pada aktivitas bidding process, project management & administration, engineering, procurement, heat exchanger installation, dan pre-commisioning & commissioning dengan total keseluruhan durasi proyek yaitu 543 Hari.
Central gathering station 10 (CGS-10) accommodates all fluids from several oil wells. Incoming fluid in the CGS-10 area is currently 212,000 BOPD. In 2030, production will increase by 312,000 BOPD. Several scenarios carried out resulted in the conclusion that the heat exchanger performance was not normal because the maximum outlet temperature of the fluid under various conditions did not reach 175°F. After assessing the capacity adequacy of existing facilities, it is necessary to add a heat exchanger. In this engineering practice, mechanical design analysis is carried out based on process data sheets and project scheduling based on material take off (MTO) analysis in civil & piping construction work, assisted by Microsoft Project software which makes it easier to create engineering, procurement & construction (EPC Schedules). From this engineering practice, the material Tubes SA 213 TP316L was obtained; Tubesheet, Baffles/Tube Support & Floating Head Cover SA 240-316L ; Tie Rods & Spacers SS 316L ; Bolt & Nut SA-193-B7 & SA-194-2H ; Shell & Shell Cover SA 516 Gr.70 ; Shell Flange SA 105; Channel/Bonnet, Channel Cover & Channel Flange SA 105 + SA 240-316L Clad. The critical path includes bidding process, project management & administration, engineering, procurement, heat exchanger installation, and pre-commissioning & commissioning activities with a total project duration of 543 days."
Depok: Fakultas Teknik Universitas Indonesia, 2024
PR-PDF
UI - Tugas Akhir Universitas Indonesia Library
Sparrow, E.M.
Belmont, CA: Brooks/Cole, 1970
536.33 SPA r
Buku Teks SO Universitas Indonesia Library
Dwiki Prasetyo
"Perkembangan ilmu pengetahuan serta teknologi yang kian pesat saat ini menuntut setiap individu untuk terus berkarya. Berbagai institusi juga berlomba-lomba untuk melakukan riset yang dapat bermanfaat bagi kehidupan manusia. Salah satu fenomena yang sering dijumpai dalam menunjang keseharian kita adalah fenomena penguapan. Suatu proses penguapan yang terjadi pada bahan bakar cair, yang saat ini masih menjadi sumber energi utama di dunia. Pengujian tetesan merupakan salah satu langkah yang dapat dipergunakan untuk mengetahui karakteristik yang dimiliki sehingga dapat meningkatkan kinerja yang efektif dan juga efisien. Salah satu parameter utama dari analogi perpindahan panas dan massa yang dimiliki pada pengujian tetesan adalah nilai dari bilangan Lewis yang dimiliki adalah sama dengan satu. Berbagai model telah dirumuskan guna memperoleh kesesuaian perhitungan perpindahan panas dan massa suatu zat.
Berbagai peneliti juga telah melakukan percobaan menggunakan cairan yang berbeda. Permasalahan yang ditemukan adalah cairan yang memiliki nilai Lewis tidak sama dengan satu akan menunjukkan korelasi yang kurang baik. Pada penelitian kali ini, dilakukan analisis lebih mendalam mengenai fenomena yang dapat menyebabkan korelasi kurang baik tersebut. Didapatkan hasil bahwa korelasi yang kurang baik tersebut timbul karena pengaruh dari stagnan film model yang digunakan. Konsentrasi cairan pada stagnan film menuju lingkungan tampak patah dan hal tersebut dirasa tidak natural.
The development of science and technology which is rapidly increasing now requires each individual to continue working. Various institutions are also competing to conduct research that can benefit human life. One phenomenon that is often found in supporting our daily life is the phenomenon of evaporation. An evaporation process that occurs in liquid fuels, which is still the main energy source in the world. Drop test is one step that can be used to determine the characteristics possessed so as to improve effective and efficient performance. One of the main parameters of the analogy of heat and mass transfer in the droplet test is that the value of the Lewis number is equal to one. Various models have been formulated in order to obtain a suitable calculation of the heat transfer and mass of a substance. Various researchers have also conducted experiments using different liquids. The problem found is a liquid that has a Lewis value not equal to one will show a bad correlation. In this study, a more in-depth analysis of the phenomena that can cause such unfavorable correlations. The results show that the unfavorable correlation arises because of the influence of the stagnant film model used. The concentration of fluid in the stagnant film into the environment seems broken and this is not natural."
Depok: Fakultas Teknik Universitas Indonesia, 2019
T55118