Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 41290 dokumen yang sesuai dengan query
cover
Patty, Servas Mario
Jakarta: Yayasan Servas Mario, 1999
920.71 SER m
Buku Teks  Universitas Indonesia Library
cover
Darwis [Tere Liye], 1979-
Jakarta: Sabak Grip Nusantara, 2022
899.221 DAR m
Buku Teks  Universitas Indonesia Library
cover
Anto Sulaksono
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1992
S27962
UI - Skripsi Membership  Universitas Indonesia Library
cover
Universitas Indonesia, 1993
S28140
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hadi Purnama
Depok: Universitas Indonesia, 1996
S28254
UI - Skripsi Membership  Universitas Indonesia Library
cover
Heri Adha
Depok: Fakultas Teknik Universitas Indonesia, 1993
S38356
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
"Semburan radio matahari tidak selalu ditemui pada kejadian badai geomagnet yang kuat meskipun pada umumnya intensitas badai akan lebih kuat bila flare yang
mengakibatkan badai ini dikuti oleh semburan radio. Flare yang lebih besar mempunyai kemungkinan yang lebih tinggi untuk disertai dengan semburan radio. Semburan radio yang terkait sebagian besar adalah tipe II yang terjadi bersama-sama dengan tipe IV. Akan tetapi importansi flare ternyata tidak mempunyai keterkaitan yang erat dengan intensitas badai geomagnet."
620 DIR 3:2 (2008)
Artikel Jurnal  Universitas Indonesia Library
cover
Indar Kustiningsih
"Limbah yang dihasilkan oleh industri, dewasa ini telah menjadi permasalahan serius yang dapat menghambat terciptanya lingkungan yang bersih dan sehat. Salah satu metode pengolahan limbah yang sangat prospektif dan ramah lingkungan adalah dengan metode fotokatalisis yang menggunakan katalis semikonduktor TiO2. Agar metode ini dapat lebih optimal maka perlu dikembangkan konfigurasi reaktor yang efektif dengan menggunakan katalis TiO2 bentuk lapisan tipis (film) dan energi foton dari sinar matahari. Pada penelitian ini, pelapisan katalis TiO2 dari Degussa P25 dilakukan dengan menggunakan perekat epoksi dan dengan metode spin coating, sedangkan fotoreaktor yang digunakan adalah reaktor plat bertingkat (RPB), reaktor silinder berputar (RSB) dan reaktor tubular "Y" collector (TVC). Dari masing-masing reaktor tersebut ditentukan kondisi optimalnya, yaitu laju sirkulasi limbah untuk RPB, putaran silinder untuk RSB, laju sirkulasi limbah dan sudut reflektor untk TVC. Ketiga reaktor tersebut dibandingkan kinerjanya dalam mengolah limbah Cr(Vl) dan fenol secara simultan pada kondisi optimal masing-masing reaktor dengan energi foton dari sinar matahari. Hasil eksperimen menunjukkan katalis TiO2 dalam bentuk film yang dibuat dengan metode spin coating lebih aktif dibandingkan dengan menggunakan perekat epoksi. Luas permukaan aktif RPB, RSB dan TVC masing-masing sebesar 4500 cm², 4398 cm² dan 1778 cm², sedangkan berat katalis di RPB, RSB dan TVC masingmasing sebesar I,57 gram, 2,19 gram dan 0,57 gram. Kondisi optimal untuk RPB diperoleh pada laju sirkulasi limbah sebesar 8,1 liter/menit, untuk RSB pada putaran silinder sebesar 120 rpm, untuk TVC pads laju sirkulasi sebesar 10,5 literlmenit dengan sudut reflektor sebesar 90° untuk sumber foton dari lampu UV dan 150° untuk sinar matahari. Dari ketiga reaktor yang digunakan, RSB merupakan konfigurasi reaktor yang paling optimal untuk mengolah Cr(VI) dan fenol secara simultan. Pada cuaca yang cerah (intensitas rata-rata sinar matahari 894 μW/m²), reaktor tersebut mampu mengolah 10 liter limbah Cr(VI) dan fenol pada konsentrasi awal 10 ppm hingga dibawah ambang baku mutu limbah. Konsentrasi akhir Cr(Vl) dan fenol setelah tiga jam masing-masing mencapai 0,47 ppm dan 0,40 ppm.

Waste that produced by industries recently has become serious problem in creating clean and healthy environment. One of more prospective and friendly environment method for waste treatment is photo catalysis method which using semiconductor catalyst TiO2. In order to optimize the method; it has to develop effective reactor configuration by using TiO2 catalyst, in the form of thin layer and photon energy from sunray. In this experiment coating TiO2 catalyst from Degusa P25 done by using epoxy glue and by using spin coating method, while photoreactor use in this experiment are cascade plate reactor (RPB), rotating drum reactor (RSB) and tubular V collector reactor (TVC). The optimal condition of each reactor have to definite are rate of waste circulation for RPB, rotation speed for RSB, rate of waste circulation and reflector angle for TVC. Performance of three reactor are compared in the way they treat Cr(VI) and phenol waste simultantly at the optimal condition of each reactor with photon energy from solar light. The experiment result show that TiO2 catalyst, in the form of thin layer, which made by spin coating method is more active than TiO2 catalyst made by using epoksi glue. Width of active surface of RPB, RSB and TVC are 4500 cm², 4389 cm² and 1778 cm², while catalyst weight in each RPB, RSB and TVC are 1.57 gr, 2.19 and 0.57 gr, optimal condition for RPB obtains at rate of waste circulation 8.1 L/min, rotating drum for RSB gains at 120 rpm, for TVC the rate of circulation obtains at 10.5 llmin with reflector angle is 900 if photon?s source is from ITV lamp and reflector angle is 150° if photon?s source is from solar light. From the three reactor used in this experiment, RSB is the most optimal configuration reactor for treat Cr (VI) and phenol simultantly. At the sunny weather (intensity of rate solar light 894 μW/m²) the reactor can treat 10 liter Cr (VI) and phenol waste at initial concentration is 10 ppm until below the threshold of waste standard quality. Final concentration of Cr (VI) and phenol miter 3 hours can be reach at 0.47 ppm and 0.40 ppm."
Depok: Fakultas Teknik Universitas Indonesia, 2005
T16179
UI - Tesis Membership  Universitas Indonesia Library
cover
Ardiansyah
"ABSTRAK
Energi matahari termasuk kategori enengi yang terbamkan (renewables
energy). Sumber energi in! mempunyai keterbatasan pada ketersediaan yang
hanya didapat pada siang had, maka dari itu tangki penyimpanan energi
sangat diperiukan untuk menyimpan energi tersebut dan digunakan pada
waktu yang lain (malam atau pagi ban).
Teknik CFD (Computational Fluid Dynamics) dapat dipergunakan untuk
memprediksi pola aiiran, distribusi kecepatan, massa jenis dan temperatur
dari suatu fluida yang terjadi di daiam tangki. Dengan perhitungan berbantuan
komputer, simulasi ini dapat memperlihatkan tingkat stratifikasi temperatur
sehubungan dengan kualitas energi yang tersimpan. Penyeiesaian numeiik
dilakukan pada domain tiga dimensi. Validasi atas basil simulasi dilakukan
dengan pengukuran temperatur daiam tangki pada beberapa titik vertikal.
Tujuan dari pekerjaan ini adalab untuk menyajikan simulasi numerik transien
tiga dimensi dari tangki penyimpanan energi sebagai alat bantu desain dan
optimasi.
Optimasi atas suatu desain tangki penyimpanan dapat berupa penentuan sisi
masukan, dimana pengaturan sisi masukan dengan spesifikasi aiiran yang
sama akan memberikan temperatur air keluaran yang berbeda.

ABSTRACT
Solar energy is one kind of renewabies energy. Source of this energy has a
iimitation of avaiiibiiity which only avaiiabie in the sunny day. Hence the
thermal energy storage tank is urgently needed to store the energy and to be
used in the other time (moming or night).
CFD (Computational Fluid Dynamics) technique can be utilized to predict the
fluid flow, temperature, density and velocity distribution of fluid that occurred in
tank. By computer aided calculation, flie simulation can show the temperature
stratification level referring to quality of stored energy. Numerical solution is
conducted on three dimension domain. Validation to the simulation result is
compared to the measured temperature in tank at vertical locations. Intention
of this work is to present the three dimensional transient numerical simulation
of thermal energy storage as a tool of design and optimisation.
Design optimisation of a storage tank can be in the form of determination of
inlet configuration, where arrangement of inlet side with the same flow
specification will give different temperature stratification and outlet
temperature."
2005
T40472
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>