"In Indonesia presently there still exist some power plants with 1960s technology which are operated manyally. The aim of this paper is to design an automatic voltage goes back to the reference value when any disturbance occurs. The design result can be applied to newly built power plants as well as to modernize old power plants. The design uses model matching methods. With model matching method the regulator is designed so that the trnasfer function of the designed control system resembles that of the reference model. Its performance was validated through computer simulation using electrical power nonlinear model of 4th order. from simulation when the reference was changed the following tracking performance was obtained: rise time 1.7 sec, over shoot 7,3 % and settling time 5.7 . sec. On the oder hand, from the fault simulation the following regulation performance was obtained: over shoot 4 % settling time 4.7 sec. and steady state error 0%."
KEENTER
Artikel Jurnal  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1999
S39532
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rinaldy Dalimi
"Changing the toad will affect to the value of the voltage at the customer side. In general, the voltage is very sensitive to the increasing or decreasing of the toad So that, it is needed to have the voltage regulator. The static VAR Compensator (SVC) can be used as a voltage regulator, which is responsive and accurate to maintain the voltage constant if the toad is changed."
2001
JUTE-15-2-Jun2001-189
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Eko Wahyu Supriyadi
"ABSTRAK
Peningkatan keandalan sistem tenaga lisirik adalah suatu tuntutan dalam rangka usaha untuk meningkatkan pelayanan terhaLlap konsumen listrik Pelayanan yang baik adalah menjadi tujuan pada setiap pengusahaan sistem tenaga listrik.
Sistem distribusi sebagai bagian dari sistem tenaga listrik, merupakan bagian terbesar asal mula terjadinya pemutusan pelayanan. OIeh karena itu tingkat keandalan suatu sistem distribusi penlu diketahui untuk memperoleb mutu pelayanan yang diinginkan.
Tingkat keandalan sistem disiribusi ditentukan oleh unjuk kerja masing-masing komponen yang mendukung beroperasinya sistem distribusi tersebut Dengan diketahuinya tingkat keanda1an sistem distribusi akan dapat diambil kebijaksanaan untuk lebih meningkatkan pelayanan.

"
1995
S34291
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lintang Hapsari Wilujeng
"

Sumber tegangan listrik merupakan salah satu kebutuhan primer modern di masa sekarang.Sumber tegangan listrik mutlak dibutuhkan untuk menjamin tetap bekerjanya peralatan tersebut.

Namun masalah yang sering dihadapi seringkali adalah sumber-sumber tegangan memiliki nilai yang jauh dibawah level tegangan kerja yang umumnya digunakan pada sistem jaringan listrik perumahan. Untuk mengatasai permasalah sumber tegangan DC tersebut, salah satu cara yang dapat diambil adalah dengan mengimplementasikan sebuah rangkaian pengubah nilai tegangan DC atau DC-DC Converter.

Pada penelitian ini penulis menawarkan rangkaian DC-DC Converter dari tipe terisolasi, yaitu Push-Pull Converter. Pemilihan Push-Pull Converter dilakukan atas beberapa alasan antara lain keandalan, kualitas daya yang dihasilkan, kemudahan untuk diaplikasikan serta yang paling penting adalah ketahanan dari gangguan yang mungkin terjadi.

Sistem dikendalikan dengan menggunakan Pengendali PI dan IP serta diuji kualitasnya dengan menggunakan Diagram Bode.Hasil dari simulasi serta analisa kestabilan menunjukkan bahwa Rangkaian Push-Pull adalah rangkaian yang tahan terhadap gangguan.


Power supply is one of the modern primary needs in the present. Power supply is absolutely necessary to ensure the continuity cooperation of the equipment. However, a problem that often encountered is voltage sources values are far below the working voltage levels that are generally used in residential electrical grid system. To handling the problems of the DC voltage source, one way that can be taken is to implement a DC voltage converter circuit or DC-DC Converter.

In this research, a series of isolated type DC-DC Converters, namely Push-Pull Converter, is being promoted. The Selection of Push-Pull Converter based on reliability and quality of generated power among others, ease of applicability and the most important is the robustness of the interference that may occur.

The system is controlled using a PI controller and the IP also stability tested using Bode plots. The results of simulation and analysis shows that the stability of the Push-Pull circuit is a circuit that is resistant to interference.

"
Fakultas Teknik Universitas Indonesia, 2014
S56862
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1998
S39379
UI - Skripsi Membership  Universitas Indonesia Library
cover
"This paper discusses optimal control of continuous-time systems,especially continuous-time linear quadratic regulator (LQR).The LQR will be implemented to determine the optimal feedback control of a scalar system....."
SIGMAAB
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Adhistira Madhyasta Naradhipa
"Untuk melakukan pengujian terhadap sistem proteksi petir pada skala laboratorium diperlukan pembangkit tegangan tinggi impuls dimana membutuhkan masukan tegangan yang cukup tinggi untuk menghasilkan pelepasan muatan dalam jarak tertentu. Kapasitor pengisi harus dibuat cukup besar agar dapat menahan tegangan masukan yang tinggi sehingga akan memakan biaya dan tempat yang besar. Erwin Otto Marx pada tahun 1923 menemukan rangkaian pembangkit tegangan tinggi impuls banyak tahap atau yang sering disebut sebagai marx generator dimana rangkaian tersebut dapat menghasilkan tegangan yang tinggi dengan masukan tegangan yang rendah. Marx generator yang dibangun terdiri dari 10 tahap dan dibuktikan bahwa dengan masukan tegangan 5kV-7.5kV dapat menghasilkan tegangan pulsa 29.14kV-43.6kV dimana persamaan estimasi tegangan keluaran adalah . Dibuktikan juga bahwa dengan keluaran tegangan tersebut dapat terjadi tegangan tembus di udara sampai dengan 1.5 cm untuk jenis sela udara jarum-pelat.

To conduct a test for lightning protection system on a laboratory scale we need high impulse voltage generator. A high impulse voltage generator need high input voltage, therefore the components of the generator have to be build strong enough to hold the stress from the high input voltage. Erwin Otto Marx found multistage high impulse voltage generator or often called marx generator, the marx generator only need low input voltage to generate high pulse voltage so the components of marx generator didn?t have to be strong enough to hold overall output voltage. The marx generator that i have build is consist of 10 stages and proven that with input voltage 5kV-7.5kV can produce 29.14kV- 43.6kV pulse voltage with the formula of voltage output estimation is . Also it proven with that pulse voltage it produce a voltage breakdown in the air up to 1.5 cm for rod-plate spark gap."
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59544
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>