roses ozonisasi katalitik sebagai pre-treatment pengolahan air gambut menjadi air minum difokuskan pada efektivitas penyisihan parameter Warna, Total Fe, COD, Total Coliform, dan Kekeruhan. Perbandingan eksperimen dilakukan antara O3, O3/UV, O3/UV/Fe, dan O3/UV/Fe tanpa KFS (Koagulasi, Flokulasi, Sedimentasi) dengan O3/UV/Fe yang dilanjutkan dengan KFS. Berdasarkan hasil percobaan, proses penyisihan optimum terjadi pada proses O3/UV/ZVI pada pH 5 + KFS (dosis tawas: 40 ppm) dengan kondisi awal meliputi kecepatan pengadukan saat ozonisasi (300 rpm), suhu (27°C ), volume sistem (250 mL), dan dosis katalis ZVI (1 g/L) dengan proses ozonisasi secara kontinyu selama 60 menit. Proses koagulasi berjalan dengan pengadukan 120 rpm (1 menit), diikuti dengan flokulasi 40 rpm (20 menit), dan sedimentasi (15 menit). Proses kombinasi O3/UV/ZVI + KFS mampu menyisihkan dua kali penyisihan, yaitu setelah O3/UV/ZVI (77%) dan setelah KFS (88%), COD (100%), Total Fe (100%), Total Coliform (100%), dan kekeruhan (89%). Pada proses yang dipilih, mekanisme kinetika orde dekolorisasi warna tidak sesuai dengan data eksperimen, dikarenakan penurunan dekolorisasi yang sangat tinggi pada rentang waktu tertentu, namun pada proses O3/ZVI reaksi berjalan dengan mekanisme kinetika orde nol dengan nilai R2 (0,9887) dengan nilai k0 sebesar 10,89 mg/L.menit yang menandakan proses dekolorisasi berjalan dengan cepat. Sementara itu, nilai EEO pada percobaan yang dipilih adalah 58,95 kWh/m3 per orde.
The catalytic ozonation process as a pre-treatment for peat water treatment into drinking water focused on the effectiveness of the removal of Color, Total Fe, COD, Total Coliform, and Turbidity parameters. Experimental comparisons were made between O3, O3/UV, O3/UV/Fe and O3/UV/Fe without KFS (Coagulation, Flocculation, Sedimentation) with O3/UV/Fe followed by KFS. Based on the experimental results, the optimum removal process occurred in the O3/UV/ZVI process at pH 5 + KFS (alum dose: 40 ppm) with initial conditions including stirring speed during ozonization (300 rpm), temperature (27°C ± 0.495), system volume (250 mL), and ZVI catalyst dose (1 g/L) with a continuous ozonization process for 60 minutes. The coagulation process runs with 120 rpm stirring (1 min), followed by 40 rpm flocculation (20 min), and sedimentation (15 min). The O3/UV/ZVI + KFS combination process was able to remove twice the removal, namely after O3/UV/ZVI (77%) and after KFS (88%), COD (100%), Total Fe (100%), Total Coliform (100%), and turbidity (89%). In the selected processes, the color decolorization order kinetics mechanism does not match the experimental data, due to the very high decrease in decolorization in a certain time range, but in the O3/ZVI process the reaction runs with a zero-order kinetics mechanism with an R2 value (0.9887) with a k0 value of 10.89 mg/L.min which indicates that the decolorization process runs quickly. Furthermore, the EEO value in the selected experiment was 58.95 kWh/m3 per order.