Pemetaan Suhu Container Chiller 1 dan 2 di PT Enseval Putera Megatrading Cabang Bekasi = Temperature Mapping of Container Chiller 1 and 2 at PT Enseval Putera Megatrading Bekasi

Nur Ainun Nisa; Mahdi Jufri, supervisor (Fakultas Farmasi Universitas Indonesia, 2023)

 Abstrak

Laporan Praktik Kerja Profesi Apoteker ini membahas terkait pemetaan suhu container chiller di PT Enseval Putera Megatrading Bekasi. Penelitian ini bertujuan untuk mengetahui letak suhu tertinggi dan suhu terendah serta titik kritis suhu pada container chiller yang dicek dengan menaruh temperature data logger di berbagai titik dan melihat apakah container chiller yang tersedia memenuhi persyaratan dan standar untuk penyimpanan produk rantai dingin atau tidak. Penelitian ini dilakukan secara observasional selama 3 hari merekam data suhu dengan temperature data logger tiap 10 menit, kemudian menarik data dari thermometer data logger mengunakan aplikasi Testo Comfort Software Basic 5.0. Dari penelitian ini dihasilkan Container chiller 1 dan 2 PT Enseval Putera Megatrading cabang Bekasi memenuhi persyaratan suhu yakni diantara 2-8o C dan titik kritisnya berada pada posisi terpanas dan terdingin di container chiller 1 terletak pada titik 3 dan 19, sedangkan pada container chiller 2 titik terpanas dan terdingin terletak pada titik 10 dan 5. Berdasarkan hasil penelitian tersebut sebaiknya limit suhu diatur pada suhu atas 7o C dan bawah 3oC untuk penanggulangan lebih cepat jika suhu berada diluar standar dan sebaiknya dalam proses penyimpanan dan pengiriman sediaan-sediaan cold chain product perlu dipantau dengan baik, terutama pada vaksin-vaksin yang memiliki indikator VVM yang mempermudah pengecekkan kestabilan obat.
This Pharmacist Professional Work Practices Report discusses temperature mapping of chiller containers at PT Enseval Putera Megatrading Bekasi. This research aims to determine the location of the highest and lowest temperatures as well as critical temperature points in chiller containers which are checked by placing temperature data loggers at various points and seeing whether the available chiller containers meet the requirements and standards for storing cold chain products or not. This research was carried out observationally for 3 days, recording temperature data with a temperature data logger every 10 minutes, and then pulling data from the thermometer data logger using the Testo Comfort Software Basic 5.0 application. From this research it was produced that Container chiller 1 and 2 of PT Enseval Putera Megatrading Bekasi branch met the temperature requirements, namely between 2-8o C and the critical points were at the hottest and coldest positions. Container chiller 1 was at points 3 and 19, while container chiller 2 was at point The hottest and coldest are located at points 10 and 5. Based on the results of this research, the temperature limit should be set at an upper temperature of 7o C and a lower temperature of 3o C for quicker response if the temperature is outside the standard and it is best to monitor the process of storing and sending cold chain products. Well, especially for vaccines that have a VVM indicator which makes it easier to check drug stability.

 File Digital: 1

Shelf
 PR-Nur Ainun Nisa4.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : PR-PDF
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Farmasi Universitas Indonesia, 2023
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : 61 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
PR-PDF 16-24-81947465 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920543137
Cover